This site uses cookies to provide an optimized shopping experience. By using this site, you agree the use of cookies within our privacy policy.
Transmation 1048
DC Process Signal Calibrator
Transmation 1048
DC Process Signal Calibrator
- Calibrates all milliamp instruments
- Calibrates voltage instruments
- Rubber boot for protection in the plant
- Calibrates all milliamp instruments
- Calibrates voltage instruments
- Rubber boot for protection in the plant
- One touch to set the output & function
- Accuracy to ±0.015%
- Four “AA” Alkaline cells for easy replacement
- Nine setpoints for each range
- Milliamp or percent display
Transmation 1048 DC Process Signal Calibrator .
Easy to use: The Transmation 1048 DC Process Signal Calibrator will check, calibrate and measure all your current signal instruments in a 4 to 20 or 10 to 50 milliamp loop plus source and measure DC Volts.
Use at every point in your loop. Source & read 0.00 to52.00 mA, simulate a 2-wire transmitter or use the 1048to supply loop power while measuring your 2-wiretransmitters. Toggle the display to show milliamps or percent span.
Source milliamps: Stroke valves, calibrate recorders and digital indicators or any other instruments that get their input from a 4 to 20 or10 to 50 mA loop. Easily set any value to within 0.01 mA with the numeric keypad.
Source millivolts and volts: Calibrate recorders, analyzers and other instruments with 0 to 100 mV, 0 to 1, 1 to 5 or 0 to 10 Volt inputs. Easily set any value to within 0.01 mV or 0.001V with the numeric keypad.
Recall output settings: Transmation 1048 DC Process Signal Calibrator easily stores up to nine setpoints per range. Instantly change the output by recalling any stored setpoint.
Fast output stepping: Automatically step through some or all of the nine stored setpoints with dwell time from 5 to 500 seconds. Plus manual stepping for full control during instrument calibration.
Calibrate using loop power: Check loop wiring and receivers by using the Model 1048 in place of a 2-wire transmitter. Simulate a changing process input to check loop response and control settings.
Read loop current: Check controller outputs or measure the milliamp signal anywhere in the loop. The Transmation 1048 DC Process Signal Calibrator measures 0.00 to52.00 mA signals with much greater accuracy than a typical multimeter. Toggle the display to show milliamps or percent of span. Power and measure 2-wire transmitters Simultaneously measure the output of a 2-wire transmitter while using the internal loop supply to power the transmitter. Handy for checking transmitters in the field or on the bench.
Read millivolts and volts: Transmation 1048 DC Process Signal Calibrator checks loop power supplies, batteries or any DC voltage in the plant from 0.00 to 90.00 mV, 0.000 to 20.000 V and 0.00 to 48.00 V.
Brand | Transmation |
---|---|
Condition | NEW |
Replacement | 850PIECAL |
UPC | 095969233804 |
Vendor Alias | 1048 |
- 1 - Pair of test leads with banana plugs and alligator clips
- 1 - Rubber Boot