Megger MGFL100

Battery Ground Fault Locator with Transmitter, Receiver, Fused Leads, AC Adapter, ICLAMP Current Sensor, and Sync Cable

MGFL100
MGFL100

Megger MGFL100

Battery Ground Fault Locator with Transmitter, Receiver, Fused Leads, AC Adapter, ICLAMP Current Sensor, and Sync Cable

MGFL100
MGFL100

The Megger MGFL100 Battery Ground Fault Locator locates ground faults on ungrounded DC and AC systems, DC battery systems, or protected IT networks and operates on systems up to 600V. This unit alarms when the real fault is found while distinguishing between real fault current and reactive current drawn by stray system capacitance.

  • Password-protected voltage/current limits
  • Ability to save/recall measurements
  • Removes need to tune out noise or capacitance
This product is available for shipping to the US, Canada, and Puerto Rico only.
$9,265.00
This item ships FREE
  • Locates ground faults on ungrounded DC/AC systems, DC battery systems, and protected IT networks
  • Ideal for applications within substations, railways, hospitals, maritime, and other industrial facilities
  • Alarms when real fault is identified, automatically distinguishes between real fault current and reactive current drawn by stray system capacitance
  • Allows for direct measurement of fault resistance, stray/leakage capacitance, fault current, and leakage current
  • Locates high impedance ground faults due to water ingress and ground faults on systems with high leakage current
  • Removes need for complicated tuning out of noise or capacitance during ground fault location
  • Users can easily trace faults with lightweight transmitter and receiver
  • Measurement of total fault resistance and leakage capacitance before user begins tracing
  • Users can see actual resistive value of value and determine if phantom shorts due to leakage current will be present
  • Traces faults by directly coupling to line either off-line or on-line with coupling filter
  • Transmitter leads fused at connectors for added safety, prevents ARC flash or other hazards from arising
  • Transmitter can be powered off of AC or internal battery power for fault locating within any location
  • Identifies side of string with ground fault, eliminates need to use DMM
  • Outputs 5.12 Hz AC signal for tracing of faults
  • AC output will not trip DC breakers like DC pulsed output can
  • Low frequency output allows for operation on low frequency 16.67 Hz systems
  • Password-protected voltage and current limits ensures protection from too much current put within system
  • Adjustable current and voltage limits eliminates risk of breaker tripping
  • Ability to save/recall measurements for constant reference

Specifications

General
  • Display: LCD
  • Transmitter Dimensions: 14.2 in. x 12 in. x 7.65 in.
  • Receiver Dimensions: 8.7 in. x 4.1 in. x 2 in.
  • Battery Life: ~4 hours
Transmitter
  • Working Voltage: 600VDC via fused test leads
  • Output Voltage Range: 0V to 50V
  • Output Current Range: 0 mA to 160 mA
  • AC Voltage Measurement Range: 0V to 50Vrms
  • DC Voltage Measurement Range: 0V to 600VDC
  • Current Measurement Range: 0 mA to 160 mA
  • Resistance Measurement Range: 0 kΩ to 400 kΩ
  • Capacitance Measurement Range: 0 μf to 19.99 μf
Receiver
  • Resistive Current Measurement Range: 0 mA to 160 mA
  • Capacitive Current Measurement Range: 0 mA to 160 mA
Compliance/Safety/EMC/Vibration
  • Compliance: IEC61010-1, CE Certified, UKCA Certified, CAT IV @ 600V
  • EMI: CISPR 11 Group 1 class A for emissions
  • EMI: IEC 61326-1 Table A.1 for immunity
  • Vibration: MIL-STD-810G
Electrical
  • AC/Adapter Input: 90V to 264VAC
  • AC/Adapter Output: 18VDC

The Megger MGFL100 Battery Ground Fault Locator locates ground faults on ungrounded DC and AC systems, DC battery systems, and protected IT networks. The instrument alarms when the real fault is found, while automatically distinguishing between real fault current and reactive current drawn by stray system capacitance.

DC Ground Faults

The MGFL100 measures the ground fault resistance, system capacitance, real fault current, and reactive leakage current. The instrument also locates high impedance ground faults due to water ingress, as well as ground faults on systems with high leakage current. The MGFL100 makes locating the ground fault fast and easy by alarming when the circuit with a real ground fault is located. No complicated tuning out of noise or capacitance is required. Users can easily trace the fault with the lightweight transmitter and receiver. Users can also set both password protected voltage and current limits to ensure that they never put too much current into their system.

AC Ground Faults

Specially protected IT networks, such as those found in hospitals, are designed in such a way that any contact with a voltage carrying line is harmless. In the event of a short to earth, protection reduces current flow to zero. Important control, signal, and supply systems, such as those for railway installations, power plants, or other industrial facilities, are designed to be potential-free and are monitored by earth fault indicators in order to ensure safe and uninterrupted operation. Short-to-ground faults in IT networks, control lines or, for example, signal lines in railways are referred to as earth faults.

While a single earth fault will not disrupt the service, a second earth fault carries a high risk of partial or complete installation breakdown. For this reason, any earth fault must be located and repaired as fast as possible. The MGFL100 allows tracing of these faults by directly coupling to the line. This can be done either off-line or on-line by using a coupling filter.

An Array of Features

The MGFL100 transmitter measures the total fault resistance and leakage capacitance before users start tracing. This allows users to not only see the actual resistive value of the fault, but also determine if there will be phantom shorts due to leakage current. The receiver directly measures the resistive fault current and the leakage current. The MGFL100 will provide a visual, as well as an audible alarm when a real ground fault is located. It will not alarm on circuits that draw leakage current due to capacitance. Users will be easily able to see which circuits have the real resistive fault. This will prevent users from chasing phantoms. There is no tuning required, and the measurements are done automatically.

The transmitter leads are fused at the connectors for safety. ARC flash is always a concern when connecting to a battery string. The battery string is a DC system. There is no zero crossing to dampen an ARC flash on a DC system. The fused leads will open to prevent a hazard from arising. The fused leads will keep a mistake from becoming a disaster.

Users can set both voltage and current limits. This ensures that neither the voltage nor the current will exceed circuit limits. These limits are password protected, so they cannot be accidentally changed. This ensures there is no accidental breaker tripping.

The transmitter can be powered off of AC or battery power. This allows for fault locating in any location. The MGFL100 will also identify the side of the string with the ground fault so there is no need to use a DMM. The 5.12 Hz AC signal allows for tracing of the fault, which is ideal for operation on noisy systems. The AC output will not trip DC breakers like a DC pulsed output can. The low frequency output allows for operation on low frequency 16.67 Hz systems.

Users can ultimately locate faults on both AC or DC systems. The MGFL100 will locate faults on ungrounded DC systems, including high resistance center grounds, or IT grounded AC systems with the use of an optional IT isolation filter (not included). The receiver will also trace AC line current on any type of system.

More Information
Country of OriginUnited States
BrandMegger
ConditionNEW
Vendor AliasMGFL100
  • 1 - Transmitter (1011-259)
  • 1 - Receiver (1011-261)
  • 1 - Set of Fused Transmitter Leads (1013-440)
  • 1 - Transmitter AC Adapter (1014-426)
  • 1 - Set of Transmitter Rechargeable Batteries (90028-218)
  • 1 - ICLAMP Current Sensor (1011-353)
  • 1 - Receiver 9V Battery (23415)
  • 1 - Sync Cable (1011-540)
  • 1 - Transmitter Safety Ground (1011-352)
  • 1 - Carrying Bag (2012-180)