Fluke Multimeters: Which One is Right for You?


Fluke DMMs for Basic Electrical Testing


Equipped with cutting-edge features, Fluke DMMs provide unparalleled performance in electrical measurements. From voltage and current to resistance and continuity, these devices deliver accurate readings with utmost reliability, ensuring that you can trust the results every time. With their high resolution and fast response time, Fluke DMMs empower you to quickly diagnose and troubleshoot electrical issues, saving you valuable time and effort.

All Fluke Digital Multimeters

114 Electrical DMM

Applications: Basic testing

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.5 %

AC bandwidth: 1 kHz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 600 V

Current AC/DC: No

Resistance: 40 MΩ

Frequency: No

Capacitance: No

Temperature: No

Continuity / Diode test: Yes

VoltAlert™, non-contact voltage detection: No

Low input impedance (LoZ): Yes

Microamps: No

IP rating: IP42

Safety rating (IEC 61010) CAT III: 600 V

Safety rating (IEC 61010) CAT IV: None

115 Digital Multimeter

Applications: Field service; Mechanical

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.5 %

AC bandwidth: 1 kHz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 600 V

Current AC/DC: 10 A

Resistance: 40 MΩ

Frequency: 100 kHz

Capacitance: 9999 μF

Temperature: No

Continuity / Diode test: Yes

VoltAlert™, non-contact voltage detection: No

Low input impedance (LoZ): No

Microamps: No

IP rating: IP42

Safety rating (IEC 61010) CAT III: 600 V

Safety rating (IEC 61010) CAT IV: None

116 Digital Multimeter

Applications: HVAC

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.5 %

AC bandwidth: 1 kHz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 600 V

Current AC/DC: 600 μA

Resistance: 40 MΩ

Frequency: 100 kHz

Capacitance: 9999 μF

Temperature: 400° C (752° F)

Continuity / Diode test: Yes

VoltAlert™, non-contact voltage detection: No

Low input impedance (LoZ): Yes

Microamps: Yes

IP rating: IP42

Safety rating (IEC 61010) CAT III: 600 V

Safety rating (IEC 61010) CAT IV: None

117 Electrician's DMM

Applications: Electrical

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.5 %

AC bandwidth: 1 kHz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 600 V

Current AC/DC: 10 A

Resistance: 40 MΩ

Frequency: 100 kHz

Capacitance: 9999 μF

Temperature: No

Continuity / Diode test: Yes

VoltAlert™, non-contact voltage detection: Yes

Low input impedance (LoZ): Yes

Microamps: No

IP rating: IP42

Safety rating (IEC 61010) CAT III: 600 V

Safety rating (IEC 61010) CAT IV: None

179 True-RMS DMM

Applications: General purpose

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.09 %

AC bandwidth: 1 kHz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 1000 V

Current AC/DC: 10 A

Resistance: 50 MΩ

Frequency: 100 kHz

Capacitance: 9999 μF

Temperature: 400° C (752° F)

Continuity / Diode test: Yes

VoltAlert™, non-contact voltage detection: No

LoZ: low input impedance: No

Microamps: No

IP rating: None

Safety rating (IEC 61010) CAT III: 1000 V

Safety rating (IEC 61010) CAT IV: 600 V

Fluke DMMs for Advanced Troubleshooting


Unleash the power of precision with Fluke's state-of-the-art Advanced Troubleshooting Digital Multimeters. Designed for professionals who demand accuracy and efficiency in their troubleshooting endeavors, these cutting-edge tools redefine what it means to achieve flawless results. With unrivaled accuracy and a wide range of measurement functions, these multimeters empower you to tackle complex electrical problems with ease and confidence.

All Fluke Digital Multimeters

3000 FC Digital Multimeter

Work environment: Residential / Commercial

Feature highlights: Wireless (Bluetooth) / Remote viewing capability

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.09 %

AC bandwidth: 1 kHz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 1000 V

Current AC/DC: 400 mA

Resistance: 50 MΩ

Frequency: 100 kHz

Capacitance: 9999 μF

Temperature: No

Conductance: No

Duty cycle / Pulse width: No / No

Continuity / Diode test: Yes

Motor Drive (ASD) Measurements: No

Microamps: No

Insulation test: No

IP rating: IP54

Safety rating (IEC 61010) CAT III: 1000 V

Safety rating (IEC 61010) CAT IV: 600 V

1587 FC 2-in-1 Insulation DMM

Work environment: Residential / Commercial

Feature highlights: Multimeter with insulation tester (megging)

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.09 %

AC bandwidth: 5 kHz

Auto / Manual ranging: No

Voltage AC/DC: 1000 V

Current AC/DC: 400 mA

Resistance: 50 MΩ

Frequency: 200 kHz

Capacitance: 9999 μF

Temperature: 500° C (932° F)

Conductance: No

Duty cycle / Pulse width: No / No

Continuity / Diode test: Yes

Motor Drive (ASD) Measurements: Yes

Microamps: No

Insulation test: Yes

IP rating: None

Safety rating (IEC 61010) CAT III: 1000 V

Safety rating (IEC 61010) CAT IV: None

87V Industrial DMM

Work environment: Residential / Commercial

Feature highlights: Multipurpose capability; Measures variable frequency drives

Counts: 20000

True-RMS readings: AC

Basic DC accuracy: 0.05 %

AC bandwidth: 20 kHz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 1000 V

Current AC/DC: 10 A

Resistance: 50 MΩ

Frequency: 200 kHz

Capacitance: 9999 μF

Temperature: 1090° C (1994° F)

Conductance: 50 nS

Duty cycle / Pulse width: No / No

Continuity / Diode test: No

Motor Drive (ASD) Measurements: Yes

Microamps: Yes

Insulation test: No

IP rating: IP30

Safety rating (IEC 61010) CAT III: 1000 V

Safety rating (IEC 61010) CAT IV: 600 V

88V Automotive DMM

Work environment: Automotive

Feature highlights: Measures conventional and hybrid vehicles

Counts: 20000

True-RMS readings: AC

Basic DC accuracy: 0.1 %

AC bandwidth: 5 kHz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 1000 V

Current AC/DC: 10 A

Resistance: 50 MΩ

Frequency: 200 kHz

Capacitance: 9999 μF

Temperature: No

Conductance: 60 nS 

Duty cycle / Pulse width: Yes / Yes

Continuity / Diode test: Yes

Motor Drive (ASD) Measurements: No

Microamps: No

Insulation test: No

IP rating: None

Safety rating (IEC 61010) CAT III: 1000 V

Safety rating (IEC 61010) CAT IV: 600 V

Fluke DMMs for Preventative Maintenance


Don't wait for equipment failures to disrupt operations. Stay one step ahead with Fluke's cutting-edge Digital Multimeters (DMMs), designed specifically for preventative maintenance. Fluke's DMMs empower you to detect potential issues before they escalate, ensure smooth operations, and reducing costly downtime.

All Fluke Digital Multimeters

789 ProcessMeter™

Work environment: Industrial / Utilities

Feature highlights: Integrated loop calibration; HART communications / diagnostics

Voltage DC: 1000 V

Voltage AC (True-RMS): 1000 V

Current DC: 30 mA, 1 A

Current AC: Yes

Resistance: 40 MΩ

Frequency: 20 kHz

Loop supply: 24 V / -

279 FC True-RMS Thermal DMM

Work environment: Industrial / Utilities

Feature highlights: Integrated infrared camera

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.0.09 %

AC bandwidth: 500 Hz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 1000 V

Current AC/DC: 2500 A AC (w/iFlex™)

Resistance: 50 MΩ

Frequency: 100 kHz

Capacitance: 9999 μF

Temperature: No

dB: No

Conductance: No

Duty cycle / Pulse width: No / No

Continuity / Diode test: Yes

Motor Drive (ASD) Measurements: Yes

Low input impedance
Microamps (LoZ): No

Microamps: No

IP Rating: IP40

Safety rating (IEC 61010) CAT III: 1000 V

Safety rating (IEC 61010) CAT IV: 600 V

8808A Bench Multimeter

Work environment: Industrial / Utilities

Feature highlights: Bench usage

Display: Dual

Resolution (digital): 5.5

Measurements: AC Volts, DC Volts, AC Current, DC Current, Frequency, Ohms, Continuity, Diode

Basic V DC accuracy (% Reading +% Range): 0.01 + 0.003

Advanced measurements/ functions: 2 x 4 wire ohms, freq, i-Leakage, dedicated setup keys

Math: Null, dBm, dB, Min, Max

Analysis: Limit compare

Interfaces: RS-232, USB (optional; not included)

Safety rating (IEC 61010-2-030) CAT II: 600 V, 1000 V Max

289 True-RMS Logging DMM

Work environment: Industrial / Utilities

Feature highlights: Performs highly accurate data logging

Counts: 6000

True-RMS readings: AC

Basic DC accuracy: 0.0.09 %

AC bandwidth: 500 Hz

Auto / Manual ranging: Yes / Yes

Voltage AC/DC: 1000 V

Current AC/DC: 2500 A AC (w/iFlex™)

Resistance: 50 MΩ

Frequency: 100 kHz

Capacitance: 9999 μF

Temperature: No

dB: No

Conductance: No

Duty cycle/Pulse width: No

Continuity/diode test: Yes

Motor Drive (ASD) Measurements: Yes

Low input impedance
Microamps (LoZ): No

Microamps: No

IP Rating: IP40

Safety rating (IEC 61010) CAT III: 1000 V

Safety rating (IEC 61010) CAT IV: 600 V