Fluke Calibration 9100S/725-KIT

Dry-Well and Process Calibrator Bundle

9100S725KIT
9100S/725-KIT
4550143

Fluke Calibration 9100S/725-KIT

Dry-Well and Process Calibrator Bundle

9100S725KIT
9100S/725-KIT
4550143
  • 9100S
  • Temperature range: 35°C to 375°C (95°F to 707°F)
  • Accuracy: ±0.25°C at 50°C; ±0.25°C at 100°C; ±0.5°C at 375°C
This product is available for shipping to the US, Canada, and Puerto Rico only.
Replaced with:
Fluke Calibration 9100S-A-156
Handheld Dry-Well Temperature Calibrator with Block "A", 35 °C to 375 °C (95 °F to 707 °F)
  • 9100S
  • Temperature range: 35°C to 375°C (95°F to 707°F)
  • Accuracy: ±0.25°C at 50°C; ±0.25°C at 100°C; ±0.5°C at 375°C
  • Stability: ±0.07°C at 50°C; ±0.1°C at 100°C; ±0.3°C at 375°C
  • Rapid heating and cooling
  • Prop stand
  • RS-232 interface capability
  • Temperature scan rate control
  • Eight set-point memory
  • Adjustable readout in °C or °F
  • 725
  • Small, streamlined shape
  • Rugged, reliable design stands up to field use
  • Easy to read measure/source screen lets you view input and output simultaneously
  • Measure volts, mA, RTDs, thermocouples, frequency and ohms
  • Test sensors and transmitters
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Support flow meter testing with frequency and CPM functions
  • Perform fast linearity tests with auto-step and auto-ramp features
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Handle fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms

The Fluke Calibration 9100S725KIT Dry-Well and Process Calibrator Bundle includes the 9100S Handheld Dry-Well Temperature Calibrator, which may be used as a portable instrument or bench top temperature calibrator for calibrating thermocouple and RTD temperature probes. This instrument is small enough to use in the field, and accurate enough to use in the lab. Calibrations may be done over a range of 35°C to 375°C (95°F to 707°F). Temperature display and setability resolution is 0.1 degrees.

The temperature is accurately controlled by Fluke's digital controller. The controller uses a precision platinum RTD as a sensor and controls the well temperature with a triac driven heater.

The Fluke Calibration 9100S-A-156 LED front panel continuously shows the current well temperature. The temperature may be set, using the control buttons, to any desired temperature within the instrument's range. Multiple fault protection devices insure user and instrument safety and protection.

The Fluke Calibration 9100S/725-KIT also includes the 725 Multifunction Process Calibrator, which can test and calibrate almost any process parameter. Measure and source mA, volts, temperature (RTDs and thermocouples), frequency and ohms. From the moment you pick it up, the Fluke 725 is ready to perform. Its simple controls (without menus), make operation easy.

More Information
Country of OriginChina
BrandFluke Calibration
Catalog4550143
ConditionNEW
Replacement9100SA156
UPC095969767729
Vendor Alias9100S/725-KIT
  • 1 - Multifunction Process Calibrator (725)
  • 1 - 9100S Dry Well with Block "A" Configuration