Fluke 393FC-IRR-TLPV

Solar Testing Bundle with 393 FC True-RMS Clamp Meter, IRR2-BT Solar Irradiance Meter, and TLPV1/TLPV2 Test Lead Sets

393FCIRRTLPV
393FC-IRR-TLPV
6022112

Fluke 393FC-IRR-TLPV

Solar Testing Bundle with 393 FC True-RMS Clamp Meter, IRR2-BT Solar Irradiance Meter, and TLPV1/TLPV2 Test Lead Sets

393FCIRRTLPV
393FC-IRR-TLPV
6022112

The Fluke 393FC-IRR-TLPV Solar Testing Bundle provides users with the 393 FC True-RMS Clamp Meter, IRR2-BT Solar Irradiance Meter, TLPV1 Test Lead Set, and TLPV2 Solar Clamp Test Lead Set. Users are provided with the tools to safely perform maintenance and testing of photovoltaic (PV) systems up to CAT III 1500V.

  • AC Current Range (Flexible Current Probe): 999.9A, 2500A
  • Jaw Opening: 34 mm
  • Irradiance Range: 50 to 1400 W/m²
This product is available for shipping to the US, Canada, and Puerto Rico only.
$1,499.99
This item ships FREE

393 FC True-RMS Clamp Meter

  • Designed for technicians working in DC environments up to 1500V
  • Ideal for solar array, wind power, electric railway, and data center battery bank applications
  • iFlex flexible current probe offers extended AC current measurements up to 2500A
  • Thin jaw and flexible probe allows for easy access to cables in crowded combiner boxes
  • Probe can be twisted through extremely small spaces and provides accurate current measurements
  • Test leads designed with user's work in mind and rated to CAT III 1500V
  • IP54 rated for use outdoors on solar arrays and wind power systems
  • DC power measurement shows readings in kVA units
  • Audio polarity indicator helps prevent accidental miswires
  • Visual continuity turns provide bright green light on display, ideal for working in dark or noisy environments
  • Logging and reporting of test results via Fluke Connect software

Specifications

Measurements
  • AC Current Range (Jaw): 999.9A
  • AC Current Range (Flexible Current Probe): 999.9A, 2500A
  • DC Current Range: 999.9A
  • AC Voltage Range: 600V, 1000V
  • DC Voltage Range: 600V, 1500V
  • mV DC Range: 500 mV
  • Amps Frequency Range (Jaw): 5 Hz to 500 Hz
  • Amps Frequency Range (Flexible Current Probe): 5 Hz to 500 Hz
  • Voltage Frequency Range: 5 Hz to 500 Hz
  • DC Power Range: 600 kVA (600V DC), 1500 kVA (1500V DC)
  • Resistance Range: 600Ω, 6000Ω, 60 kΩ
  • Capacitance Range: 100 µF, 1000 µF
General
  • Automatic Power-OFF: 20 min.
  • Jaw Opening: 34 mm
  • Flexible Current Probe Diameter: 7.5 mm
  • Flexible Current Probe Cable Length: 1.8m
Safety
  • General: IEC 61010-1, Pollution Degree 2
  • Measurement: IEC 61010-2-032 CAT III 1500V/CAT IV 600V, IEC 61010-2-033 CAT III 1500V/CAT IV 600V

IRR2-BT Solar Irradiance Meter

  • High-precision mono-crystalline solar sensor for instantaneous irradiance measurements up to 1400 W/m²
  • Two options for temperature measurement including built-in temperature sensor or external suction mount temperature probe
  • External temperature probe allows for measuring ambient and panel temperature
  • Integrated compass measures and documents roof or site orientation
  • Inclination sensor shows roof and PV panel tilt while surveying, installation, or adjusting installation
  • Mounting solution ensures proper irradiance measurements
  • Instant I-V curve readings via wireless communication with SMFT-1000

Specifications

Measurement
  • Irradiance Range: 50 to 1400 W/m²
  • Temperature Range: -22°F to 212°F (-30°C to 100°C)
  • Inclination Angle Range: -90° to 90°
  • Compass Range: 0° to 360°

TLPV1 Test Lead Set

  • Designed for safe PV measurements with Staubli MC4 connectors
  • Ideal for regular testing and troubleshooting of Staubli MC4 PV panels
  • Includes TLPV-UTOOL for easy connector disconnect
  • LeadWrap allows for organized test lead management

TLPV2 Solar Clamp Test Lead Set

  • MC4 connectors for seamless connection between solar panels and inverters
  • Ensures safe DC power measurements on photovoltaic systems
  • Facilitates troubleshooting and maintenance of solar PV circuits
  • Nickel-plated contacts for long-lasting durability
  • Includes PV unlocking tool for easy disconnect of Staubli MC4 connectors

The Fluke 393FC-IRR-TLPV Solar Testing Bundle provides users with the 393 FC True-RMS Clamp Meter, IRR2-BT Solar Irradiance Meter, TLPV1 Test Lead Set, and TLPV2 Solar Clamp Test Lead Set all in one convenient bundle.

The Fluke 393 FC True-RMS Clamp Meter is designed for technicians who work in DC environments up to 1500V. These environments include solar arrays, wind power, electric railways, and battery banks within data centers for uninterruptable power supplies. The clamp measures up to 1500V DC, 1000V AC, and up to 999.9A DC or AC through the clamp jaw. The iFlex flexible current probe offers extended AC current measurements up to 2500A.

This clamp meter features a thin jaw for access to cables in crowded combiner boxes. When measuring AC current, the iFlex flexible probe offers users unparalleled access to cables even in tight spaces. This probe can be twisted through extremely small spaces and provides accurate current measurements. The test leads are designed with the user's work in mind and are also rated to CAT III 1500V.

Being IP54 rated, the 393 FC is ideal for work outdoors on solar arrays and wind power systems. When capturing DC power measurement, readings are shown in kVA units while the audio polarity indicator helps prevent accidental miswires. Visual continuity turns provide a bright green light in the display which is ideal when working in dark and noisy environments. Additionally, users can connect to the Fluke Connect software to perform logging and reporting of the captured test results.

The Fluke IRR2-BT Solar Irradiance Meter has been designed to simplify the installation, commissioning, and troubleshooting of photovoltaic (PV) arrays. With this single handheld tool, users can measure irradiance, temperature, inclination, and direction of the solar array. With a rugged and compact design and an easy-to-read, high-contrast LCD screen to read measurements in direct sunlight, this comprehensive PV site surveyor can go wherever users go. The simple user interface, instantaneous solar irradiation measurements, and built-in temperature sensor make it easy to meet the IEC 62446-1 requirements for testing, documenting, and maintaining photovoltaic systems. Additionally, the integrated compass and inclination sensor allow users to quickly measure and document roof and on-site orientation, pitch, and panel tilt while surveying, installing, or adjusting an installation.

Whether working on a roof-mounted system or on a large field installation, the Fluke IRR2-BT Solar Irradiance Meter is a single-handed solution ideal for solar installers and technicians.

The Fluke TLPV1 Test Lead Set is designed for safe PV measurements with the Staubli MC4 connectors in which these test leads are ideal for regular testing and troubleshooting of Staubli MC4 PV panels. The TLPV-UTOOL is included for easy disconnection of the connectors and the LeadWrap offers organized test lead management.

The Fluke TLPV2 Solar Clamp Test Lead Set features MC4 connectors for a seamless connection between solar panels and inverters. These test leads ensure safe DC power measurements on photovoltaic systems in order to facilitate troubleshooting and maintenance the solar PV circuits. The nickel-plated contacts ensure long-lasting durability and the included PV unlocking tool allows for the easy disconnection of the Staubli MC4 connectors.

More Information
BrandFluke
Catalog6022112
ConditionNEW
UPC195112130551
Vendor AliasFLK-393FC-IRR-TLPV
  • 1 - True-RMS Clamp Meter (393 FC)
  • 1 - iFlex Flexible Current Probe, 18 in. (I250018)
  • 1 - Magnetic Hanging Strap (TPAK)
  • 1 - Premium Carrying Case
  • 1 - Test Lead Set with Right-Angle Plugs/Safety Caps, CAT III 1500V, Red/Black
  • 1 - Solar Irradiance Meter (IRR2-BT)
  • 1 - External Temperature Probe with Suction Cup (FLK-80PR-IRR)
  • 1 - Mounting Bracket (MB1-IRR)
  • 1 - Carrying Case with Shoulder Strap
  • 4 - AA Alkaline Batteries
  • 1 - User Manual
  • 1 - MC4 Test Lead Set, Red/Black, CAT III 1500V, 30A (TLPV1)
  • 1 - LeadWrap Test Lead Wrap
  • 1 - MC4 Solar Power Clamp Test Lead Set, Red/Black, CAT III 1500V, 30A (TLPV2)
  • 2 - Solar PV Connector Unlocking Tools (TLPV-UTOOL)