Your company account is blocked and you cannot place orders. If you have questions, please contact your company administrator.

E-Mon E50-480800-R-03-N-SP-KIT

Class 5000 kWh Submeter, 480V, 800A, NEMA 4X, BACnet MS/TP, EZ-7 Ethernet, Green Net Meter 1 Phase, 2 Split-Core Sensors w/ 2V Out

E50480800R03NSP
E50-480800-R-03-N-SP-KIT

E-Mon E50-480800-R-03-N-SP-KIT

Class 5000 kWh Submeter, 480V, 800A, NEMA 4X, BACnet MS/TP, EZ-7 Ethernet, Green Net Meter 1 Phase, 2 Split-Core Sensors w/ 2V Out

E50480800R03NSP
E50-480800-R-03-N-SP-KIT
  • Brand Name: E-Mon D-mon
  • Condition: NEW
$2,230.10
This item ships FREE
  • Advanced 4-line display showing:
  • - kWh delivered, received and Net kWh
  • - kWh/Demand (with peak date and time)
  • - Power factor per Phase
  • - Real-time load in kW
  • - Amps per Phase
  • - Volts per Phase
  • On-board set-up option for:
  • - IP Address
  • - Meter date/time
  • - ID codes for EZ7, Modbus and BACnet
  • 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption (optional solid-core current sensors available in 100 & 200 amp)
  • Onboard diagnostics and verification system
  • Two external meter inputs (water, gas, BTU, etc.), channels 5 & 6
  • Phase loss alarm (N.O. Contact)
  • Built-in RS-485 communications capability supports up to 52 Class 3200, 3400, 5000 meters and/or IDR interval recorders (or combinations not to exceed 52 devices per channel)
  • Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel
  • Communications include built-in RS-485 & Ethernet and optional telephone modem
  • Protocols
  • - EZ7
  • - Modbus RTU
  • - Modbus TCP/IP
  • - BACnet MS/TP*
  • - BACnet IP*
  • - LonWorks FT-10 (Twisted Pair)*
  • Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels; data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days; maintains interval data storage in a first-in, first-out format
  • Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data
  • Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits; optional single-phase 3-wire configuration available
  • Industrial grade green JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone); knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure
  • Optional outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure
  • UL/CUL Listed: Certified by independent test lab to ANSI C12.20 national accuracy standards (+/- 0.2% from 1% to 100% of rated load)
  • CE Mark approved
  • Meter meets or exceeds MID accuracy standards
  • BACnet protocol is BTL certified, LonWorks protocol is LonMark Certified
  • MV-90 Compatible (EZ7 only)
Model No.
Qty.
Cart Subtotal (%1 items):
All taxes, shipping fees and discounts will be applied at checkout.