E-Mon E50-4801600-R-06-N-SP-KIT
Class 5000 kWh Submeter, 480V, 1600A, NEMA 4X, RTU Modbus TCP/IP Green Net Meter Single Phase, 2 Split-Core Sensors w/ 2V Out
E504801600R06NSP
E50-4801600-R-06-N-SP-KIT
E-Mon E50-4801600-R-06-N-SP-KIT
Class 5000 kWh Submeter, 480V, 1600A, NEMA 4X, RTU Modbus TCP/IP Green Net Meter Single Phase, 2 Split-Core Sensors w/ 2V Out
E504801600R06NSP
E50-4801600-R-06-N-SP-KIT
- Advanced 4-line display showing:
- - kWh delivered, received and Net kWh
- - kWh/Demand (with peak date and time)
- - Power factor per Phase
- - Real-time load in kW
- - Amps per Phase
- - Volts per Phase
- On-board set-up option for:
- - IP Address
- - Meter date/time
- - ID codes for EZ7, Modbus and BACnet
- 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption (optional solid-core current sensors available in 100 & 200 amp)
- Onboard diagnostics and verification system
- Two external meter inputs (water, gas, BTU, etc.), channels 5 & 6
- Phase loss alarm (N.O. Contact)
- Built-in RS-485 communications capability supports up to 52 Class 3200, 3400, 5000 meters and/or IDR interval recorders (or combinations not to exceed 52 devices per channel)
- Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel
- Communications include built-in RS-485 & Ethernet and optional telephone modem
- Protocols
- - EZ7
- - Modbus RTU
- - Modbus TCP/IP
- - BACnet MS/TP*
- - BACnet IP*
- - LonWorks FT-10 (Twisted Pair)*
- Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels; data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days; maintains interval data storage in a first-in, first-out format
- Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data
- Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits; optional single-phase 3-wire configuration available
- Industrial grade green JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone); knockouts: 1 1/16" (3/4" cond.) on bottom and 7/8" (1/2" cond.) on top of enclosure
- Optional outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16" KO on bottom of enclosure
- UL/CUL Listed: Certified by independent test lab to ANSI C12.20 national accuracy standards (+/- 0.2% from 1% to 100% of rated load)
- CE Mark approved
- Meter meets or exceeds MID accuracy standards
- BACnet protocol is BTL certified, LonWorks protocol is LonMark Certified
- MV-90 Compatible (EZ7 only)