This site uses cookies to provide an optimized shopping experience. By using this site, you agree the use of cookies within our privacy policy.
E-Mon E10616
PowerSmart Plus Essential Meter with Modbus RTU, JIC Steel Enclosure, without Sensors
E10616
E10616
E-Mon E10616
PowerSmart Plus Essential Meter with Modbus RTU, JIC Steel Enclosure, without Sensors
E10616
E10616
The E-Mon D-Mon E10616 PowerSmart Plus Essential Meter with Modbus RTU is a multifunctional power meter measuring over 100 energy parameters for revenue metering, power quality, and harmonic analysis. This unit is ideal for energy metering and power quality analysis of specific critical loads to an entire building.
- Modbus RTU
- Standalone unit without sensors
- Pre-installed in JIC steel enclosure with lockable window panel/3-phase voltage terminal block
- Modbus RTU
- Standalone unit without sensors
- Pre-installed inside JIC steel enclosure with lockable window panel, 3-phase voltage terminal block
- Class 0.5S IEC 62053-22 four-quadrant active/reactive energy polyphase static meter
- Ampere/Volt demand meter with True RMS, power, power factor, neutral current, voltage, current unbalance frequency
- Dual Panel mounting configuration for 4 in. round/96 x 96 square DIN new, retrofit installations
- High precision 3-phase meter monitoring for voltage, current, power, power factor, neutral current, energy, demand, frequency, load profile, voltage/current unbalance
- 3.5 in. monochromatic LCD display with 240 x 128 dots resolution, adjustable update time, backlit, user-defined brightness settings
- 3 voltage inputs, 3 current transformer-isolated AC inputs for direct connection to power line, via potential/current transformers
- Three-phase total/per phase energy measurements of active, reactive, apparent energy counters
- Time-of-use, 4 totalization, tariff energy/demand registers x 8 tariffs, 4 seasons x 4 types of days, 8 tariff changes per day
- Automatic daily energy, maximum demand profile log for total/tariff registers
- Voltage/current THD, current TDD/K-Factor, up to 40th order harmonic
- Voltage/current harmonic spectrum/angles
- Real-time 'scope mode' waveform monitoring capability
- Simultaneous 6-channel one-cycle waveform capture at rate of 64 samples per cycle
- 16 control setpoints, programmable thresholds/delays
- 1-cycle response time
- Non-volatile memory for long-term event/data recording
- Event recorder for logging internal diagnostic events/setup changes
- Two data recorders for programmable data logs on periodic basis, automatic daily energy/maximum demand profile log
- Auto-scroll option with adjustable page exposition time, auto-return to default page
- LED bar graph showing percent load with respect to user-definable nominal load current