Desco 19224

Ground Hub Monitor, 220VAC, Asian Plug

19224
19224

Desco 19224

Ground Hub Monitor, 220VAC, Asian Plug

19224
19224

The Desco 19224 Ground Hub Monitor (220V AC/Asia Plug) continuously monitors the path-to-ground integrity of the outlet for verifying wiring orientation. The LED lighting provides the user with a visual indication for properly wired outlets and the visual and audio alarms activate when a failure occurs.

  • Monitors AC outlet wiring/path-to-earth ground
  • Constant visual indicator
  • Visual/audio fault alarms
  • NIST calibrated
$199.95 Price $221.81
This item ships FREE
  • Monitors AC Outlet's Wiring and Path to Earth Ground
  • Continuously monitors the path to ground integrity of the outlet meeting the ANSI/ESD S6.1 requirement for verifying wiring orientation
  • LEDs provide a visual indication that outlet is properly wired for grounding purposes of an ESD Control Plan
  • Visual and audio fault alarms
  • Alarms activate instantly when a failure occurs, alerting user and supervisor of a problem
  • Six banana jacks and six screws for #8 ring terminals
  • Provides numerous groundable points for wrist straps, mats, carts, tools, and other items
  • May also be connected to other grounding hubs

The Desco 19224 Ground Hub Monitor, 220VAC, Asian Plug confirms the integrity of the resistance path from the common ground point to electrical ground. It is designed in accordance with ESD TR 12-01 to "monitoring equipment ground connections." When the 19224 is plugged into an AC outlet, the green LED illuminates when both the outlet's wiring is correct and the path to equipment ground via the equipment grounding conductor is intact. The monitor provides 12 verified ground points when in PASS condition. The red LED illuminates when either the outlet's wiring is incorrect or the path to equipment ground is defective. The outlet ground line is tested by measuring voltage between it and the neutral line. It is normal to have a few volts of AC induced on the neutral line. If the Ground Hub Continuous Monitor measures only a few volts, the ground line to neutral impedance is low and the ground line would make a suitable ESD ground point. If the monitor measures more than just a few volts between ground and neutral, this indicates either that they are not referenced to each other or that the outlet and associated wiring should be checked for loose connections. In this case, the Ground Hub Continuous Monitor will sound a warning alarm and display a red FAIL indication and should not be used for an ESD grounding point until corrected.

More Information
Country of OriginUnited States
ConditionNEW
BrandDesco
Vendor Alias19224
  • 6 - 10-32 x 1/4 in. Screws
  • 6 - #10 Split Washers
  • 1 - Certificate of Calibration