  • Brand Name: Refurb. Agilent
  • Condition: REFURBISHED
  • Low, normal mode noise specifications assure quality power for precision circuitry applications enabling you to power your design with confidence
  • Accurate voltage/current programming and read back capability
  • Protection for your device under test (DUT) includes over voltage, over current, and over temperature
  • Three independent outputs in one instrument
  • Compact, intuitive package
  • 4.3-inch LCD color display shows voltage and current of all three channels at once
  • Low current measurement
  • Auto series/parallel connections
  • Data logging
  • Output sequencing
  • Output LIST
  • Remote sensing
  • Digital I/O port
  • USB Host port for data logging/data storage
  • Earth ground reference at rear panel
  • Outputs at front and rear panel
  • I/O interfaces: USB/LAN Opt-GPIB
  • Power output: 80 W
  • DC output rating (0 to 40°C):
    • Channel 1: 0 to 6 V/0 to 5 A
    • Channel 2: 0 to 25 V/0 to 1 A
    • Channel 3: 0 to 25 V/0 to 1 A
  • Output ripple and noise (20 Hz to 20 MHz):
    • Normal mode voltage: < 350 μVrms/2 mVpp
  • Programming accuracy ± (% of output + offset):
    • Voltage/Current:
      • Channel 1: 0.03% + 2 mV/0.04% + 3 mA
      • Channels 2 and 3: 0.03% + 5 mV/0.04% + 2 mA
  • Readback accuracy ± (% of output + offset)
  • Voltage/Current:
    • Channel 1: 0.04% + 2mV/0.04% + 5 mV
    • Channels 2 and 3: 0.04% + 3mA/0.04% + 3 mA
  • Low range current, 20 mA: 0.25% + 80 μA
  • Command processing time: < 10 ms
  • Up/down programming settling time to within 1% of total excursion:
    • Up full load:
      • Channel 1: 11 msec
      • Channels 2 and 3: 50 msec
    • Up no load:
      • Channel 1: 10 msec
      • Channels 2 and 3: 20 msec
    • Down full load:
      • Channel 1: 13 msec
      • Channels 2 and 3: 45 msec
    • Down no load:
      • Channel 1: 100 msec
      • Channels 2 and 3: 150 msec

The Agilent/Keysight Technologies E36312A Triple Output Programmable DC Power Supply, 6 V, 5 A and 2 x 25 V, 1 A, 80 W, LAN, USB is ready for your application. With low output ripple/noise and accurate voltage/current measurement, you can test with confidence and power your next insight.

Confidently Supply Your DUT With Clean, Reliable Power

Accurate voltage/current programming and readback capability provide excellent control on the power supply and power measurement. The low, normal mode noise specifications assure quality power for precision circuitry applications, enabling you to power your design with confidence. Besides the 0.01% load and line regulation, the E36312A can also maintain a steady output when power line and load changes occur, giving you more peace of mind. The built-in capability to measure low range current reduces the need for an external multimeter and simplifies the setup.

To further improve the voltage regulation and measurement accuracy of the DC outputs, the E36312A models offer 4-wire sensing capability, also called remote sensing, on each of the rear terminals. Remote sensing permits the output module to monitor and regulate its output voltage directly at the DUT input terminals instead of the power supply's output terminals. Four wire sensing is particularly useful for compensating for the voltage drops in the power leads when using the higher output currents generated by the E36313A. For convenience, an internal relay controls switching between 2-wire mode (local sensing) and 4-wire mode (remote sensing) thus eliminating the need for shorting bars or jumpers commonly found on other bench power sources.

Reduce Space, Cost And Noise With Convenient Benchtop Capabilities

All three outputs on the E36312A can be turned on and off independently, so you are essentially getting three power supplies in one instrument which saves cost on maintenance. It also saves space on the bench as you can power up multiple analog/digital circuitries or devices with a single instrument.

For even more voltage or current, Channel 2 and Channel 3 of the E36312A set series or parallel mode on the front panel to double the output voltage (up to 50 V) or current (up to 4 A) respectively.

The E36312A is one of the quietest power supplies in its class. It automatically lowers the fan speed under the load/ no load condition to eliminate annoying acoustic noise through a thermal control circuit. At a typical noise level of less than 26 dBA under no load condition and less than 50 dBA under full load condition, it allows you to work in a quiet and undisturbed environment.

Simplify Set Up And Operation With Intuitive And Easy-to-Use Front-Panel Interface And Connectivity

The 4.3-inch LCD color display shows the voltage and current of all three channels with different views. Color coding of the knobs, display and binding posts helps avoid setup and connection errors. Two individual knobs for voltage and current with rotary encoder control for precise setting and keypad allows quick adjustments and configurations in less time.The E36312A also offer rear output terminals for easy wiring, which is ideal for both bench and system setup.

The E36312A supports operation via, SCPI (standard commands for programmable instruments) programming language, IVI (interchangeable virtual instruments) driver, Web Browser or BenchVue. The E36312A is also code compatible with the E3631A to assist in migration to a more modern power supply.

Data Logging And Output Sequencing For Increased Productivity

Emulating the normal behaviors of your power subsystems early in the design process, including controlling multiple power supply voltage sequences, measuring wide dynamic ranges of current, and varying the speed of the power supply voltage to reflect real circuit characteristics is critical your design's success. The E36312A offer additional capabilities for emulating and analyzing power behaviors.

Logging data is key to reviewing test set ups and repeating test conditions. The E36312A simultaneously logs data on all three DC outputs, both voltage and current measurements, spaced by a programmable sample period, to the large color display and a file. Export the data logger display in PNG, BMP file formats or export the time stamped data as a CSV file for reports and documentation. The built-in battery backup real time clock allows for proper time-stamping of logged data.

Simulate power problems or normal operation with either sequencing or list mode. Sequence each channel on the E36312A models individually to turn on or turn off with a delay. Generate complex sequences of output changes with rapid, precise timing synchronized with internal or external signals by using LIST mode.

More Information
BrandRefurb. Agilent
ConditionREFURBISHED