This site uses cookies to provide an optimized shopping experience. By using this site, you agree the use of cookies within our privacy policy.
AEMC PEL 113 - w/o sensors
3-Phase Power and Energy Logger with LCD Screen (No Sensors)
AEMC PEL 113 - w/o sensors
3-Phase Power and Energy Logger with LCD Screen (No Sensors)
The AEMC PEL 113 - w/o sensors (2137.64) 3-Phase Power and Energy Logger performs single, dual, and three-phase power and energy testing and can be installed without cutting off the power supply. The three voltage and three current channels perform auto recognition of the connected current sensors and probes.
- Sensors not included
- Backlit monochrome LCD screen for easy viewing of measurements
- Magnetized for mounting inside power panels
- Direct replacement for PEL 103 (2137.62), offers 5x faster operation speed
- Backlit monochrome LCD screen allows for easy viewing of measurements
- Sensors sold separately, please see Accessories and Options tab for compatible models
- 3x voltage and 3x current channels with auto-recognition of connected current sensors and probes
- Performs single, dual (split-phase), and 3-phase (Y, Δ) testing
- Performs measurements for most DC, 50 Hz, 60 Hz, and 400 Hz distribution systems
- Supports 17 types of connections or electrical distribution systems
- RMS and DC measurements with 128 samples/cycle simultaneously on each phase
- Captures active, reactive (N, D, Qf) and apparent power values along with active energy values
- Fundamental active power values (Pf), balance active power values (P+), and unbalance active power (Punb)
- Phase data includes cos (φ), tan (Φ), and power factor (PF)
- Total Harmonic Distortion (THD) calculation for currents and voltages
- 32 alarms allow for configuration, remote alerts, and automatic reports
- Recordings cover several months for long-term logging
- Effortless energy logging allows for smarter power management
- Wide range of applications including predictive/preventive maintenance, energy audits, cost optimization, and IT infrastructure maintenance
- Ideal for users in renewable energies, process industries, build construction/renovation, public services/transport, and data center fields
- Simple-to-use minimal button operation
- Compact and magnetized for mounting inside power panels
- Rigid molded elastomer housing protects instrument
- Expandable storage records data on SD card up to 32 GB
- Able to be installed without cutting off power supply
- Powered directly from phase, eliminates reliance on battery source
- 2137.90 600V CAT III Power-to-Phase Adapter (sold separately) required for phase-powered operation, supplies instrument with power during extended operation
- DataView software allows for configuration, data retrieval, real-time measurement display, data analysis, and report generation
- Downloadable PEL app on Android devices provides comprehensive and instantaneous motor electrical parameters such as rotation speed, efficiency, and torque
- PEL app provides users with ability to configure measurements/recordings and display data in real-time
- Multiple connectivity options supports USB, Ethernet, Wi-Fi access points (up to 5x clients), and remote access with DataViewSync
- Remote access and real-time monitoring for viewing and analyzing power consumption from anywhere
- Secure SMTP email transmission via DataViewSync
Specifications
General
- Number of Voltage Channels: 3 (V1, V2, V3)
- Number of Current Channels: 3 (L1, L2, L3)
Measurements
- Phase-Neutral (V) Voltage Range: 10V to 1000VAC/DC
- Phase-Phase (U) Voltage Range: 10V to 1000VAC
- AC Current Range (Meter Only): 5 mA to 12 kAAC
- DC Current Range: 50 mA to 1300ADC
Other
- NEC Article 220.87 Load Study Compliant: Yes, DataView configuration button and report templates
- External Power Supply: 120V/240V line power cord
Safety/Mechanical
- Electrical Safety (IEC 61010): 600V CAT IV/1000V CAT III
- Ingress Protection: IP54/IP20
The AEMC PEL 113 - w/o sensors (2137.64) 3-Phase Power and Energy Logger is the ideal tool for optimizing energy efficiency, reducing costs, and improving the performance of electrical systems. This model is a direct replacement for the PEL 103 (2137.62) in which speed up to five times faster is provided.
The PEL 113 - w/o sensors (2137.64) model features an on-unit backlit monochrome LCD screen for easy viewing of measurements. No sensors are included. Please see the Accessories and Options tab to purchase sensors that are compatible with this instrument.
The PEL 113 offers users three voltage inputs, three current inputs, and a compact design that is magnetized for mounting inside power panels. The quadruple backlit digital display offers users easy readings of measurements even in darker spaces.
Operation of the PEL 113 is simple and performs single, dual (split-phase), and three-phase power and energy testing. The three voltage channels and three current channels offer auto recognition of connected current sensors and probes. 32 alarms on the instrument allow for configuration, remote alerts, and automatic reports. Users are able to store recorded data on the SD card with the option to expand the storage size up to 32 GB.
This instrument can be installed without cutting off the power supply. Powered directly from the phase, this instrument eliminates the need to rely on a battery for power. Powering from the phase requires the 2137.90 600V CAT III Power-to-Phase Adapter (sold separately) which supplies the instrument with power during extended operation.
Efficient Energy Consumption for any Industry
Simple to interface everywhere, the PEL 113 caters to a wide range of users. Within the renewable energy sector, users working with photovoltaic, wind, hydroelectric, thermal, or thermo-dynamic applications can benefit from this instrument. Process industry users within metallurgy, glassmaking, paper, chemicals, or agri-food fields can streamline processes. Building construction and renovation operations, such as within housing and other facilities, can review energy consumption. Users within public services or transport sectors can utilize this instrument for monitoring of lighting, roads, motorways, tunnels, or rails. Within data centers, consumption monitoring and analysis can be performed.
The PEL 113 enables users to analyze power and energy across a variety of applications for more efficient consumption.
Energy Audits
Users performing voluntary or mandatory operations that aim to reduce energy consumption can utilize the PEL 113 for building, housing, infrastructure, equipment, and more. Measurement campaigns focused on energy for a comprehensive diagnosis of an electrical installation can be easily implemented. Ultimately, the PEL 113 allows for users to identify the case of overconsumption by equipment or overbilling.
Preventive and Predictive Maintenance
With the PEL 113, users can monitor industrial equipment, evaluate the sizing of a power factor correction cabinet, or determine the redistribution of loads on an electrical grid. Users can also analyze the consumption levels of air conditioning, ventilation, and heating systems in order to make the adjustments as needed. For motor diagnostic capabilities, users can capture the measurement of a motor's speed, efficiency, and torque without using mechanical sensors.
Keep Overconsumption within Data Centers under Control
The vast volume of data requiring constant management can place a heavy load on the servers and cooling systems. Consumption monitoring is a key factor for preventing failures and overconsumption. By monitoring and analyzing these loads more closely with the PEL 113, users can help control costs and make the data center more reliable.
Network Communication
The PEL 113 is equipped with a wide range of wired and wireless communication possibilities.
Ethernet
Where possible, the PEL 113 can be connected together via an Ethernet-type wired link. The Ethernet link can be used at the same time as Wi-Fi connections.
Wi-Fi
The PEL 113 offers two Wi-Fi operating modes. This instrument can be connected to the company's IT network via a server or addressed directly by a PC or smartphone.
DataViewSync
A secure server is provided so that users can view data from anywhere in the world.
USB
USB connections can be used to configure or download the data along with taking control of the instrument no matter the circumstances.
DataView Data Analysis and Reporting Software
To expand upon the capabilities of the PEL 113, users can download the DataView software. Recorded data is able to be downloaded, displayed, and analyzed through the software. This software allows users to display and analyze real-time data along with configuring the functions and parameters all from their PC. Views, templates, and reports can be configured to specific needs and a complete library of configurations can be created and stored.
To better analyze captured data, waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs, and stored alarms can be displayed. Within the PEL control panel, users can find all of the necessary tools and selection buttons to review recorded data as trend plots or tabular lists. When viewing graphs, users can zoom in and out along with panning through sections in order to better analyze the data. Any standard or custom template designed by the user is able to have their report printed.
Basic information regarding the instrument can be configured including Auto Power OFF, the name and location of the instrument, display contrast and brightness of the LCD screen, setting of the real-time clock, and SD card formatting. All of this can be easily accomplished from the 'general' tab. The 'measurement' tab specifies the electrical distribution system, voltage ratios, and nominal frequency. Within the 'recording' tab, users can configure the instrument to measure and record over a user-selectable recording period. Users can select demand intervals and view available memory for data storage.
Country of Origin | France |
---|---|
Brand | AEMC |
Condition | NEW |
- 1 - PEL 113 3-Phase Power and Energy Logger with LCD Screen (2137.64)
- 4 - Tests Leads in Reeling Boxes, Black, 10 ft.
- 4 - Alligator Clips, Black
- 12 - Color-Coded Input ID Markers
- 1 - SD Card, 8 GB, Installed
- 1 - USB SD Card Reader
- 1 - USB Type A-to-Type B Cable
- 1 - Power Cord, 115V
- 1 - NiMH AAA Battery, 8.4V, Installed
- 1 - Small Classic Tool Bag
- 1 - DataView Software
- 1 - Quick-Start Guide
- 1 - User Manual