The ACR Systems SRP-010-128K SmartReader Plus 10 is a 4-Channel (Temperature, RTD Temperature) Data Logger that precisely measures temperature over a wider range than a thermistor without sacrificing accuracy or resolution. Setup and download information with the IC-102 interface cable. With built-in menus, logger setup is fast and easy.
- Operate with TrendReader 2 Software
- Memory Size: 128 KB
- 12-bit resolution
- Connect up to 10 data loggers
- Note: SmartReader Data Loggers require TrendReader 2 Software to operate
- Note: Probes, transformers and transducers not included
- Number of Channels: Four (4)
- One (1) channel for ambient temperature
- Three (3) channels for temperature (with RTD probes)
- Monitor and record temperature in four different locations
- Wide temperature range
- Extreme precision and accuracy
- Memory Size: 128 KB
- 12-bit resolution
- 10-year battery life
- 3-year warranty
- Fast sample rates
- Remote access via modem or Ethernet
- Network capable (connect up to 10 data loggers)
- Alarm dial-out
- User configurable
- Case Material: Noryl plastic
- External Connector: Removable screw-type terminal strip with Common (-) connection
- Mounting: Magnetic backing or locking eyelet
- Operating Limits: -40 to 70°C (-40 to 158°F) and 0 to 95% relative humidity (non-condensing)
- Clock Accuracy: +/- 2 seconds per day
- Battery: 3.6 volt Lithium, 1 Amp-Hour
- Battery Life: 10 years under normal use (factory replaceable)
- Power Consumption: 5 to 10 microamps (continuous)
- Sampling Methods:
- Continuous (First-in, First-out - not available with sample rates faster than 8 seconds)
- Stop when full (Fill-then-stop)
- Sampling Rates: User selectable rates from 25 per second (0.04 seconds) to once every 8 hrs
- Resolution: 12-bit (1 part in 4,096)
Internal Temperature Sensor
- Type: Negative Temperature Coefficient Thermistor 10,000 ohms @ 25°C (77°F)
- Range: -40 to 70°C (-40 to 158°F)
- Accuracy: +/- 0.2°C over the range of 0 to 70°C (+/- 0.3°F over range of 32 to 158°F)
- Resolution: 0.03°C at 25°C (0.05°F at 77°F); better than 0.07°C (0.12°F) between -25 and 70°C (-13 and 158°F); better than 0.13°C (0.23°F) between -40 and -25°C (-40 and -13°F)
- Internal Temperature Sensor
- Type: Negative Temperature Coefficient Thermistor 10,000 ohms @ 25°C (77°F)
- Range: -40 to 70°C (-40 to 158°F)
- Accuracy: +/- 0.2°C over the range of 0 to 70°C (+/- 0.3°F over the range of 32 to 158°F)
- Resolution: 0.03°C at 25°C (0.05°F at 77°F); better than 0.07°C (0.12°F) between -25 and 70°C (-13 and 158°F); better than 0.13°C (0.23°F) between -40 and -25°C (-40 and -13°F)
RTD Type
- Any 100 or 1000 Ohm Platinum RTD with Temperature Coefficient of Resistance (TCR) of 0.00385
- Accuracy (100 and 1000 Ohm): +/- 0.3°C (+/- 0.54°F) + resolution
- Resolution (100 and 1000 Ohm): +/- 0.14°C (+/- 0.25°F)
- Temperature Range (100 and 1000 Ohm): -230 to 300°C (-382 to 572°F)
- Wiring Configurations: 2, 3, or 4 wire RTDs
Applications
- Food process verification
- Pharmaceutical storage monitoring
- Transportation of temperature-sensitive goods