Your company account is blocked and you cannot place orders. If you have questions, please contact your company administrator.

ACR Systems SRP-006-128K

SmartReader Plus 6 8-Channel (Temperature/Cold-Junction Compensation and External Temperature) Data Logger with 128 KB Memory

SRP006128K
SRP-006-128K
01-0122

ACR Systems SRP-006-128K

SmartReader Plus 6 8-Channel (Temperature/Cold-Junction Compensation and External Temperature) Data Logger with 128 KB Memory

SRP006128K
SRP-006-128K
01-0122

The ACR Systems SRP-006-128K SmartReader Plus 6 is an 8-Channel (Temperature/Cold-Junction Compensation and External Temperature) Data Logger. Easily record temperature from any J, K, S, T or E type thermocouple probe. With 7 inputs for thermocouple probes and an on-board cold-junction thermistor, it is one of the most versatile thermocouple data loggers available.

  • Operate with TrendReader 2 Software
  • Memory Size: 128 KB
  • Connect up to 10 data loggers
$1,546.00
This item ships FREE
  • Note: SmartReader Data Loggers require TrendReader 2 Software to operate
  • Note: Probes, transformers and transducers not included
  • Number of Channels: Eight (8)
    • One (1) channel for ambient temperature (also for coldjunction compensation)
    • Seven (7) channels for temperature (with thermocouples)
  • Monitor and record temperature in eight different locations
  • Monitor extremely high temperatures
  • Monitor temperature over a wide range
  • Use with variety of different temperature probes:
    • General purpose
    • High temperature
    • Low temperature
    • Waterproof temperature
    • Oven temperature
    • Skin surface temperature
    • Pipe surface temperature
  • Greater accuracy and resolution than SR6
  • Memory Size: 128 KB
  • 12-bit resolution
  • 10-year battery life
  • 3-year warranty
  • Fast sample rates
  • Remote access via modem or Ethernet
  • Network capable (connect up to 10 data loggers)
  • Alarm dial-out
  • User configurable
  • Case Material: Noryl plastic
  • External Connector: Removable screw-type terminal strip with Common (-) connection
  • Mounting: Magnetic backing or locking eyelet
  • Operating Limits: -40 to 70°C (-40 to 158°F) and 0 to 95% relative humidity (non-condensing)
  • Clock Accuracy: +/- 2 seconds per day
  • Battery: 3.6 volt Lithium, 1 Amp-Hour
  • Battery Life: 10 years under normal use (factory replaceable)
  • Power Consumption: 5 to 10 microamps (continuous)
  • Sampling Methods:
    • Continuous (First-in, First-out - not available with sample rates faster than 8 seconds)
    • Stop when full (Fill-then-stop)
  • Sampling Rates: User selectable rates from 25 per second (0.04 seconds) to once every 8 hrs
  • Resolution: 12-bit (1 part in 4,096)

Internal Temperature Sensor

  • Type: Negative Temperature Coefficient Thermistor 10,000 ohms @ 25°C (77°F)
  • Range: -40 to 70°C (-40 to 158°F)
  • Accuracy: +/- 0.2°C over the range of 0 to 70°C (+/- 0.3°F over the range of 32 to 158°F)
  • Resolution: 0.03°C at 25°C (0.05°F at 77°F); better than 0.07°C (0.12°F) between -25 and 70°C (-13 and 158°F); better than 0.13°C (0.23°F) between -40 and -25°C (-40 and -13°F)
  • Accuracy: +/- 0.5% of range + resolution

Applications

  • Monitor performance of gas-fired heating equipment
  • Verifying concrete curing temperatures
  • Process verification