800Plus Universal Digital Meters |
|
Specifications |
FR Counter/Timer |
VF Counter/Timer |
QD Quaduture Input |
|
Display |
# of Digits |
6 digits |
|
Range |
-99999 to +99999 |
|
LED Indicators |
3 status indicators |
|
Color |
Red or Green |
|
Accuracy |
Full scale or reading |
±2ppm |
0.015%FS |
±2ppm |
|
Span TEMPCO |
0.003% of reading/°C- except load cell(0.0015% rdg./°C)
& FR(±1ppm/°C typical) |
|
Zero TEMPCO |
0.001FS/°C |
|
Conversion |
General |
1 / period time:
Gate time + 30ms + 2 periods of the input signal (max): gate time
selectable 0 to 199.99 seconds |
|
Noise Rejection |
General |
Common Mode voltage from DC to 60 Hz safety rated to
250 VAC; 4.2 kVp per high voltage test |
|
Case |
NEMA 4 (IP65) 1/8 DIN case made of high impact 94V-0
UL rated plastic |
|
Environmental |
Temperature: Operating0°C~55°C, Storage-40°C~85°C;
Relative humidity 95% at 40°C non-condensing |
|
Operating Power |
General |
Frequency 47 to 440 HZ and DC, consumption 5.3 Watts
maximum |
|
Standard |
Universal power supply 85 to 264 VAC, 90 to 370 VDC |
|
Option |
Universal power supply 8 to 28 VAC, 9 to 37 VDC |
|
Frequency |
General |
Selectable with shorting jumpers on power supply
printed circuit board (normal setting 10 VDC) |
|
Outputs |
5 VDC, ±5%, 100 mA max., 10 VDC, ±5%, 120 mA max., 24
VDC, ±5%, 50 mA max. |
|
Isolation (power ground) |
Safety rated to 250 VAC, 4.2 kV peak per high voltage
test |
|
Dual Controller Option |
General |
NEMA 4 (IP65) 1/8 DIN case made of high impact 94V-0
UL rated plastic |
|
Setup |
Set point values may be entered from front panel
pushbutton or via RS-232 or RS-485 |
|
Output Operation |
Either may be set to operate above or below set point,
latching or non-latching, or output disabled |
|
Filtering |
Comparison to the set points may be from filtered or
unfiltered input signal |
|
Time Delay |
Selectable time delay of output status change from 1
to 128 readings |
|
Lockouts |
Pushbutton control of display and change of set
points,
or display of set points, or disable |
|
Alarm Status Indicators |
Either of two red LED’s may be set to indicate when
output is on or off, or they may be disabled |
|
Relay Output |
General |
10 A at 240 VAC, 8 A at 24 VDC contact rating; safety
certification: VDE, UL, CSA |
|
Isolation |
Coil to contacts :Safety rated to 250VAC, 4.2 kV
peak; Between open contacts :Withstand 1 kVrms |
|
Response to input signal |
Pick-up:26 milliseconds typical; Release:22
milliseconds typical |
|
Optotransistor output |
General |
Voltage rating:30VDC; Current rating:100 mA minimum
at 1.2 VDC maximum |
|
Isolation |
Safety rated to 250 VAC, 4.2 kV peak per high voltage
test |
|
Response to Input Signal |
17 milliseconds typical |
|
Analog Output Option |
General |
Power :provided by meter, Isolation: Withstand 3750
Vrms, 8mm creepage |
|
Accuracy |
Use basic meter accuracy ±0.05% of analog output full
scale |
|
Response Time |
17 milliseconds for unfiltered input, same as basic
meter for filtered output |
|
RS-232/RS-485 |
General |
Power :provided by meter; Isolation: safety rated to
250 VAC, 4.2 kVp per high voltage test |
|
Baud Rates |
300, 600, 1200, 2400, 9600, 19200 |
|
Type/Signal Levels |
Full duplex (RS-485) / meets RS-232 and RS-485
standards |
|
BCD Output |
General |
Power : provided by meter; Isolation: safety rated to
250 VAC, 4.2 kVp per high voltage test |
|
Type/Signal Levels |
Tri-state, stored parallel / LSTTL, CMOS compatible |
|
Controls |
BCD Enable, Hold, Data ready |
|
Ordering Info |