Specifications |
Details |
|
Measuring Range |
1.000Ω to 10.00MΩ |
|
Measuring Arm |
x 1mΩ, x 10Ω + 10Ω x 10 + 100Ω x 10 +
1000Ω x10
(min. one step: 1Ω) |
|
Ratio Arms |
x 0.001 x 0.01, x 0.01, x 0.1, x 1, x 10,
100, x 1000 (M10, M100, M1000... Murray & Varley loop
testing) |
|
Accuracy |
±0.1% of reading on 100Ω to 100kΩ Range |
|
±0.3% of reading on 10Ω to 1MΩ Range |
|
±0.6% of reading on 1Ω to 10MΩ Range |
|
Temperature coefficient of
Resistance Elements |
±0.5 x 10-5
/°C at ambient temperature of 5 to
35°C (41 to 95°F) |
|
±2 x 10-5
/°C at ambient temperature of 20 to
35°C (68 to 95°F) |
|
Galvanometer (built-in) |
Sensitivity |
approx. 10µV/div. |
|
Internal Resistance |
Approx. 150Ω |
|
External Critical Damping resistance |
Approx. 800Ω |
|
Period |
within 1.5 Seconds |
|
Operating Temperature Range |
5 to 35°C (41 to
95°F) |
|
Humidity Range |
85% Max., Relative Humidity |
|
Dimensions |
182 x 226 x 128mm (7 1/4 x 9 x 4 3/4") |
|
Weight |
4.4lbs (2kg) |
|
Power source |
Three 1.5V batteries (built-in) |
|
Case |
ABS Resin |