Parameter |
Reference |
Accuracy |
|
DC Current |
400/2000A |
±1.5+2 |
|
AC Current |
400/2000A(0~1000A) |
1.5+2 (50/60Hz) |
|
3.0+4 (40~500Hz) |
|
5.0+4 (500~1kHz) |
|
2000A (1001~2000A) |
±1.5%+3 (40~1kHz) |
|
DC voltage |
400/1000V |
1.0+2 |
|
AC Voltage |
400/750V |
1.5+2 (50/60Hz) |
|
1.5+4 (40~1kHz) |
|
Resistance |
400/4000Ω |
1.5+2, Beeps at below 50+35Ω (Continuity
check) |
|
DC Output |
DC400A(0~400mV) |
±1.5%rdg ±3mV |
|
DC2000A(0~200mV) |
±1.5%rdg ±3mV |
AC400A(0~400mV)
AC2000A(0~100mV/ 0~1000A) |
±1.5%±3mV (50/60Hz) |
|
±3.0%rdg ±3mV (40~500Hz) |
|
±5.0%rdg ±3mV (500~1kHz) |
|
AC2000A(100.1~200mV/ 1001~2000A) |
±3.0%±3mV (50/60Hz) |
|
|
|
Parameter |
Specification |
|
Method of Detection |
Mean Value |
|
Diameter of Measurable conductor |
Ø55MM at maximum |
|
Display |
LCD (Digital Display: 3999 Counts) |
Response Time
(Approx.) |
2 Seconds |
|
Peak Hold |
On AC Current Range |
|
Data Hold |
On All range |
|
Range Switching |
Manual-Range (on current, voltage range)/
Auto-range (On resistance range) |
|
Ambient Temperature and Humidity |
0-40ËšC, 85% RH or less (no condensation) |
|
Influence of external Magnetic Field |
4A or less at 400 A/m |
|
Influence of Conductor Position |
±(1.5%rdg + 3dgt) or Less |
|
Circuit Voltage |
1000Vrms or less |
|
Withstanding Voltage |
5.55kV AC for one minute |
|
Power Supply |
R6P(SUM-3) x2; or LR6 x2 |
|
Battery Life |
Approx. 150 hours (continuous) |
|
Consumed Current |
Approx.9mA |
|
Sleep Function |
Automatically powered down in about 10
minutes after last switch operation |
|
Dimensions |
Approx. 105(W)x250(H)x49(D)mm |
|
Weight |
Approx. 530g |