HOME > YOKOGAWA > ANALOG-PANEL-METERS > STYLIST > INDEX yokogawa logo

Yokogawa Stylist Series Panel Meters

  • Window-, surface- and rear-panel-mount
  • 1-1/2", 2-1/2", 3-1/2" and 4-1/2" meter size
    ±2% accuracy of full scale
  • Direct replacement for many competitive products Available in UL/CSA
  • Custom scaling available for all AC or DC products
  • 90 or 95 degree scale deflection
  • Optional bezels for surface-mount permit rear-panel mounting
  • Standard movement torque to weight ratio is approximately 4 times greater than most other high-torque versions
     

Click here for larger image - Yokogawa Stylist Series Panel MetersClick here for larger image - Yokogawa Stylist Series Panel Meters
Yokogawa Stylist Series
Panel Meters Shown

 

Product Information

Ordering Info

Jump to Product Models, Prices, Accessories, and Ordering Information

PDF Help

 
The Yokogawa stylist series panel meters are available in window mount and surface mount styles and all meters meet ANSI specification C39.1. These meters are available in a variety of sizes, from 1.5 to 4.5", and feature a 90 degree arc in the AC iron vane version and a 95 degree deflection in the taut band and pivot and jewel models. Both standard and special units are available through the Yokogawa Just-in-time manufacturing system or from 40 Instrument Sales and Service Centers located throughout the United States and Canada.
 
Accuracy:
All DC and AC iron vane, ±2% of fullscale, AC rectifier type; ±3% of fullscale (60 Hz sine wave). Expanded scale voltmeters ±5% of fullscale. Special order DC with mirror back scale (DC only) 3-1/2 - 4-1/2” Available @ ±1%.
ANSI Specification:
All meters meet ANSI Specifications C-39.1
Overload:
Voltmeters (AC + DC) - 50% momentary, 20% sustained. Ammeters (AC +DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 seconds with 1 minute interval between successive applications; sustained: 20% for six hours.
 
Scale Data
ARC 90° 95°
Meter Size AC Iron Vane Taut Band/ Pivot & Jewel
1 1/2" - 1.66"
2 1/2" 2.15" 2.29"
3 1/2" 2.70" 2.85"
4 1/2" 3.80" 4.01"
Insulation Level 2600V/1 min. (2-1/2” - 4-1/2”); 1500V/1 min. (1-1/2”)
Response Time 3 seconds (Max.) - Microammeters
2 seconds (Max.) - All other DC ratings
2.5 seconds (Max.) - All AC ratings
Maximum 40% overshoot
Burden Data AC Ammeter 5 amps @ 60 Hz, 0.5VA, Max. .5 Power factor lagging, AC voltmeter - unity power factor.
 
Three Mounting Types Available in Stylist Series:
Rear Panel Window Mount, Front of Panel Surface Mount, Rear Panel Surface Mount Available with Optional Bezel

Taut Band:
Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel:
In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for high vibration environments because of the mechanism’s inherent stability and strength. Accuracy and repeatability are almost equal to the taut-band’s, and good performance from the pivot and jewel construction is the reason for its long popularity. Don’t specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meter’s ability to withstand vibration.

High-Sensitivity DC Voltmeters:
Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters:
For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is ±0.5% of full-scale value. Standard voltage spans are listed in “Ratings.”

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect — AC Meters:
Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes ±2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters:
Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
  • AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
    AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.

  • Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500µA to 30A.

  • Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = ±3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as “live-zero” and are standard.


  • Higher Accuracy: Standard calibration accuracy is ±2% of full scale. DC meters can be calibrated to ±1% of full scale as a special model in 3-1/2” and 4-1/2” with mirrored scale.

Suppressed-Zero DC Meters:
DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = ±3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as “live-zero” and are standard.

Higher Accuracy:
Standard calibration accuracy is ±2% of full scale. DC meters can be calibrated to ±1% of full scale as a special model in 3-1/2” and 4-1/2” with mirrored scale.

 

 
Stylist Series Panel Meters - General Specifications
Accuracy AC/DC Iron-Vane ±2% of full-scale
AC Rectifier Types ±3% of Full scale (60Hz sine wave)
Expanded Voltmeters ±5% of full-scale
Special Order with mirror back scale (DC only) 3-1/2 - 4-1/2” Available @ ±1%.
Overload Voltmeters (AC/DC) 50% Momentary
20% Sustained
Ammeters (AC/DC) Momentary 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications
Sustained 20% for six hours
ANSI Specification Majority of meters meet ANSI Specifications C-39.1
Insulation Level 1 1/2" 1500 Vrms Hi-pot
All Meters (other then 1 1/2") 2600 Vrms Hi-pot
Burden Data AC Ammeter 5 amps, 0.5 va, Max. 0.5 power-factor lagging @ 60 Hz.
AC Voltmeter unity power factor
Additional Notes

Severe-duty meters are available to meet CSA or UL 1437 requirements in 2-1/2” - 4-1/2” sizes.

 
Ordering Information
Stylist Series Panel Meters - Model Types
Specifications  
Voltmeters DC Zero - Left More Info And Ordering Information>>
Zero-Center More Info And Ordering Information>>
Expanded Scale More Info And Ordering Information>>
Percent Deviation ±.05% Full Scale Accuracy More Info And Ordering Information>>
AC Expanded Scale Taut Band, Moving Coil More Info And Ordering Information>>
Self-Contained More Info And Ordering Information>>
Transformer Rated More Info And Ordering Information>>
Self-Contained Iron Vane, Pivot & jewel More Info And Ordering Information>>
Transformer Rated More Info And Ordering Information>>
Ammeters DC Zero - Left Self-Contained More Info And Ordering Information>>
50mV Zero-Left, Shunt Rated More Info And Ordering Information>>
100mV More Info And Ordering Information>>
Zero-Center, Self Contained More Info And Ordering Information>>
50mV Zero-Center, Shunt Rated More Info And Ordering Information>>
AC Taut Band, Moving Coil Self-Contained, Rectifier Type More Info And Ordering Information>>
Separate Transformer, Rectifier Type More Info And Ordering Information>>
Transformer Rated, Rectifier Type More Info And Ordering Information>>
Iron Vane, Pivot & Jewel, Self-Contained More Info And Ordering Information>>
Transformer Rated More Info And Ordering Information>>
Millivoltmeters DC Zero - Left More Info And Ordering Information>>
Zero-Center More Info And Ordering Information>>
Microammeters DC Zero-left More Info And Ordering Information>>
Zero-Center More Info And Ordering Information>>
Milliammeters DC Zero-left More Info And Ordering Information>>
Zero-Center More Info And Ordering Information>>
Suppressed Zero More Info And Ordering Information>>
AC Taut Band, Moving Coil Self-Contained More Info And Ordering Information>>
Iron Vane, Pivot & Jewel, Moving Coil Self-Contained More Info And Ordering Information>>