Test Equipment Depot - 800.517.8431

View Shopping Cart | My Account

 

Free Ground Shipping for Orders over $100

Used Test Equipment
Completely refurbished,
aligned & calibrated to original
manufacturers' specifications
Used Equipment Catalog
<< Tekronix 1720 & 1730 Series Vectorscopes

Tektronix 1730 Series
Waveform Monitors Complete Specifications

Signal Input (Video and External Reference)
Return Loss >40 dB, 50 kHz to 6 MHz, power on or off
Maximum Input ±5 V DC + peak AC
Loop-through Isolation >80 dB at FSC
Channel Isolation >50 dB at FSC
Impedance >15 Ω
Vertical Deflection
Deflection Factor Within 1% of 1V
Gain Range Input signals between 0.8V and 2V can be adjusted to a 1V display; (160 mV and 400mV for X5 gain)
Position Range 1 V signal can be positioned so that peak white and sync tip can be placed at blanking level regardless or gain range
Frequency Response
Flat 50 kHz to 6 MHz within 2% (X1), within 5% (X5)
Low Pass 40 dB attenuation at FSC; Low pass response within 1% of flat response (1735: 30dB)
Chroma Nominal bandwidth 1 MHz; 2X FSC attenuation >20 dB; Chroma response within 1% of flat response
Transient Response
Preshoot <1%
Overshoot <2%
Ringing <2%
Tilt <1%
Pulse-to-Bar Ratio 0.99:1 to 1.01:1
Differential Gain <1%
DC Restoration
Clamp Time Back Porch
Frequency Response Attenuation of 60 Hz on input signal
Slow Mode <20%
Fast Mode >90%
Blanking Level Shift A 10% to 90% APL change will cause <1% of blanking level shift.  Presence or absence of color burst will cause <1% of blanking shift
PIX Monitor Output
Frequency Response 50kHz to 6 MHz within 3%
Differential Gain <1%
Differential Phase <1%
DC Level on Output <0.5V into 75Ω  load
Intensification (brightup) 180 mV DC offset on select lines
Output Impedance 75 Ω  nominal
Return Loss >30 dB, 50 kHz to 6 MHz
Input to Output (PIX MON) Gain Ratio Luminance 1:1 ±5% at 15 kHz
Calibrator
Frequency 100 kHz ±0.1 kHz
Timing Accuracy 10µs, ±0.01 µs
Amplitude 1 V, ±1%
Horizontal Deflection System
Sweep Sweep will occur with or without input signal
1-Line Repetition Rate Equal to applied line rate, magnification equals 0.2 ms/div
2-Line Repetition Rate Equal to half applied line rate, magnification equals 1 ms/div
2-Field Repetition Rate Equal to applied frame rate, magnification equals approximately X25
Timing Accuracy 1 ms/div: Within 2%
0.2 ms/div: Within 3%
Linearity Within 2%
Differential Linearity Within 2%
Sweep Magnification Registration Magnification occurs about the center of the screen
Position Range Any portion of a synchronized video sweep can be positioned in all sweep modes
Synchronization
Internal Composite video or black burst with sync ±6 dB of nominal
External Sync amplitude of 143 mV to 4V
Remote Sync 2.0 to 5.0 V square wave or 4.0V comp sync (sync polarity can be internally inverted)
RGB/YRGB Repetition rate: field rate and line rate with magnification of X25 and X10, respectively
Sweep Length 3-Step (RGB): 3.4 to 4.2 divs.
4-Step (YRGB): 2.5 to 3.1 divs.
1720 & 1730 Series Common Characteristics
Used Waveform Monitors Page Used Test Equipment Catalog
 

Used Equipment Catalog

$20.00 Minimum on Total Order