<< HP 8558B Product
PageHewlett Packard 8558B |
| FREQUENCY SPECIFICATIONS | |
| Frequency Range | 0.1 to1500 MHz |
| Frequency Spans | |
| Per Division | 5 kHz to 100 MHz/div in a 1, 2, 5 sequence |
| Zero Span | analyzer functions as a manually tuned receiver |
| Frequency Accuracy | |
| Tuning Accuracy | (+10°C to +40°C) |
| 0-195 MHz | ± (1 MHz + 20% frequency span per division) |
| 195-1500 MHz | ± (5 MHz + 20% frequency span per division) |
| Frequency Span Accuracy | ± 5% of displayed frequency separation |
| Spectral Resolution | |
| Resolution Bandwidths | eight selectable resolution (3-dB) bandwidths from 1 kHz to 3 MHz in a 1, 3 sequence. Bandwidth and frequency span are independently variable or may be coupled for optimum display when control markers are aligned |
| Resolution Bandwidth Accuracy | ± 3-dB points are ± 20% (10°C to +40°C) |
| Selectivity | (60-dB/3-dB bandwidth ratio) < 15:1 |
| Spectral Stability | |
| Residual FM | < 1 kHz p-p in 0.1 second |
| Noise Sidebands | ± 65 dB down, ± 50 kHz from center of CW signal with 1 kHz resolution bandwidth and full video filtering |
| AMPLITUDE SPECIFICATIONS | |
| Amplitude Range | -117 to +30 dBm |
| Maximum Input (damage) Levels | |
| Total Power | +30 dBm (1 Ω, 7.1 Vrms) |
| dc or ac (< 100 Hz) | ± 50 V |
| Peak Pulse Power | + 50 dBm (100 Ω, < 10 ms pulse width, 0.01% duty cycle) with ~ 20 dB input attenuation |
| Gain Compression | typically < 1 dB for -10 dBm signal, 0 dB input attenuation |
| Average Noise Level | < -107 dBm with 10 kHz resolution bandwidth, 0 dB input attenuation, and maximum (MAX) video filtering |
| Calibrated Display Range | |
| Log | 70 dB with 10 dB/div scale; 8 dB with 1 dB/div scale |
| Linear | 8 divisions with linear (LIN) amplitude scale |
| Amplitude Accuracy | |
| Calibrator | -30 dBm ± 1 dB (into 50 Ω), 280 MHz ± 300 kHz |
| Reference Level | 10 dB steps and a 12 dB vernier for calibrated adjustment from -112 dBm to +60 dBm |
| Step Accuracy (with 0 dB input attenuation) | -10 to -80 dBm: ± 0.5 dB, -10 to -100 dBm: ± 0.1 dB |
| Vernier Accuracy | ± 0.5 dB |
| Frequency Response | ± 1.0 dB with 10 dB input attenuation (includes input attenuator, mixer flatness, and internal limiter) |
| Input Attenuator | 0 to 70 dB, selectable in 10 dB steps |
| Step Accuracy | < ± 0.5 dB per 10 dB step |
| Maximum Cumulative Error | < ± 1.0 dB |
| Bandwidth Switching (Amplitude Variation) | |
| 3 MHz to 30 kHz | < ± 0.5 dB |
| 3 MHz to 1 kHz | < ± 1.0 dB |
| Display Fidelity | |
| Log Incremental Accuracy | ± 0.1 dB/dB from Reference Level |
| Log Maximum Cumulative Error | ± 1.5 dB over 70 dB range |
| Linear Accuracy | ± 3% of Reference Level |
| Spurious Responses | |
| Second Harmonic Distortion | > 70 dB below a -40 dBm input signal with 0 dB input attenuation; > 60 dB below for signals 100 kHz to 5 MHz |
| Third Order Intermodulation Distortion | > 70 dB below two -30 dBm input signals (> 5 MHz) separated by ~ 50 kHz and with 0 dB input attenuation; > 60 dB below for signals 100 kHz to 5 MHz |
| Image and Multiple Responses | > 70 dB below a -40 dBm input signal (> 5 MHz) with 0 dB input attenuation; > 60 dB below for signals 100 kHz to 5 MHz |
| Residual Responses | < -100 dBm with 0 dB input attenuation and no signal present at input |
| SWEEP CHARACTERISTICS | |
| Automatic | sweeptime is automatically adjusted to maintain absolute amplitude calibration for any combination of frequency span, resolution bandwidth, and video filter bandwidth |
| Calibrated Sweep Times | 0.1 ms to 10 sec/div in 1, 2, 5 sequence with ± 10% typical accuracy |
| Manual Sweep | spectrum analyzer may be swept manually in either direction with front panel control |
| SIGNAL INPUT CHARACTERISTICS | |
| Input Impedance | 50 Ω nominal; precision Type-N female connector |
| Input SWR | typically < 1.5 with ± 10 dB input attenuation and no signal present at input |
| OUTPUT CHARACTERISTICS | |
| 1st LO Output | BNC output provides +10 dBm nominal signal (into 50 Ω), 2.05 to 3.55 GHz |
| Probe Power | +15 V, -12.6 V, and GND (150 mA max). Use HP 1120A, 1211A, 1123A, or 1124A high impedance probes |
| Vertical Output, AUX A | BNC output (50 Ω) provides detected video from 0 to 0.8 V for 8 division deflection on CRT display |
| Penlift/Blanking, AUX B | BNC output provides 0 V pen down/unblanking signal at low impedance; 15 V penlift/blanking at 10 kΩ impedance |
| 21.4 MHz IF Output, AUX C | BNC output (50 Ω) provides a signal which is proportional to the RF input. Level is about -10 dBm (into 50 Ω) with a signal displayed at the Reference Level. Output is controlled by settings of Resolution BW, Input Atten., and Reference Level |
| Horizontal Output, AUX D | BNC output (5 kΩ) provides horizontal sweep from -5 V to +5 V for full 10 division CRT horizontal deflection |
$20.00 Minimum on Total Order
Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________
99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:
Copyright © Fotronic Corporation All Rights Reserved