| DC OUTPUT |
Voltage and current output can be adjusted over the ranges
indicated by front panel controls, analog programming, or an optional HP-IB
interface. |
| Voltage |
0-50 V |
| Current |
0-10 A |
| Maximum 200 watts output from 20 V to 50 V. |
| Load Effect |
Constant-voltage, 0.01% + 1 mV. Constant-current,
0.01% + 1 mA. |
| Source Effect |
CV, 0.01% + 1 mV; CC, 0.01% + 1 mA. |
| PARD (ripple and noise) |
rms/p-p, 20 Hz to 20 MHz; CV, 1 mV/10 mV; CC, 5 mA rms. |
| Temperature Coefficient |
CV, 0.02% + 200 µV/° C; CC
0.02% + 5 mA/°C. |
| Drift |
CV, 0.05% + 1 mV/8 h; CC, 0.05% + 5 mA/8 h. |
| Load Transient Recovery |
100 µs for output voltage to
recover within 15 mV of nominal voltage setting following a load current
change of 50% to 100% or 100% to 50% of full load current. |
| Response Time |
Maximum time for output voltage to change
between 0 to 99.9% or 100% to 0.1% of maximum rated output voltage.
Up Programming: no load, 100 ms; full load, 100 ms. Down
Programming: no load, 400 ms; full load, 200 ms. |
| Overvoltage Protection |
Trip voltage adjustable from 2.5 V to 60 V. |
| DC Output Isolation |
150 V dc. |
| Power |
100, 120, 220, or 240 V ac (-13%, + 6%), 48-63
Hz. |
| Temperature Rating |
0°C to 55°C
operating, -40°C to +75°C storage. supply is cooled by built-in
fan. |
| Size |
180 H X 212 mm D (6.97" X 8.36" X
16.6") |
| Weight |
net, 14.5 kg (32 lb); shipping, 15.9 kg (35 lb). |
| HP-IB OPTION |
| Programmable Range |
high: 0-50 V or 0-10 A
low: 0-10 V or 0-2 A. |
| Programming Speed |
Same as response time. |
| Accuracy |
hi range: CV, 0.2% +25 mV; CC, 0.2% +25 mA.
lo range: CV, 0.2% +10 mV; CC, 0.2% +25 mA. |
| Resolution |
hi range: CV, 50 mV; CC, 10 mA. (12 bit)
lo range: CV, 10 mV; CC, 2 mA. (12 bit) |
| Isolation |
250 volts dc from bus data lines to power
supply. |
| ACCESSORIES |
| 5061-0060 |
Rack mounting adapter kit for one 6002A |
| 5061-0094 |
Cabinet lock-together kit to connect two 6002As |
| 5061-0078 |
Rack flange kit to mount two locked 6002As |