4 MHz - 1300 MHz Network Analyzer Specifications

Frequency Range 4 to 1300 MHz
Spectral Purity (+ 10 dBm RF output level)
Residual FM (swept and CW) ≤7 kHz rms (10 kHz bandwidth)
Harmonics -28 dBc
Output Power Range 0 to +13 dBm typical, ± 0.5 dB flatness
Input Channel two test inputs (A and B) and one reference (R) input
Input Connectors type-N Female, 50 ohms nominal impedance
Input Port Match ³ 20 dB Return Loss (1.22 SWR)
Maximum Input Level 0 dBm at R, A, B inputs
Damage Level +20 dBm (50 Vdc)
Noise Level < -80 dBm at A and B inputs
Minimum R input level -40 dBm (³ -40 dBm required to operate R input phase-lock)
Crosstalk Between Channels > 83 dB
Magnitude Frequency Response (flatness) Absolute (A, B): ≤± 1 dB
Ratio (A/R, B/R): ≤0.3 dB
Magnitude Dynamic Accuracy ± 0.3 dB from 0 to -50 dBm, ± 0.5 dB from -50 to -60 dBm, ± 1 dBm from -60 to -70 dBm, ± 2.5 dB from -70 to -80 dBm.
Absolute Power Measurements (A, B, R) typically ± 0.5 dBm at 0 dBm, 50 MHz input
Phase Frequency Response ±2.5° (typically ±1°)
Phase Range ±180°
Phase Dynamic Accuracy ±2° from 0 to -50 dBm, ±4° from -50 to -70 dBm.
Electrical Length Adjustment Range Typically 0 to 16 cm length for transmission phase; typically 0 to 8 cm reference plane extension for reflection measurements.
DISPLAY
Measurement Functions CRT displays either polar trace or Channel 1 and Channel 2 rectilinear traces.
Video Filter typically 100 Hz (10 kHz without filter)
Graticule Size rectilinear 10 cm by 8 cm; polar 8 cm in diameter
Smith Chart Overlays 2, 1, 0.2, and 0.1 full scale (furnished)
CRT Photography Tektronix C-5B Oscilloscope Camera is recommended (UV illumination will not excite P39 CRT phosphor for graticule exposure)
Resolution 10, 2.5, 1, 0.25 dB magnitude per major division. 90, 45, 10, 2.5 degrees phase per major division.
Accuracy ±2% ±0.05 division for rectilinear trace.  Within 2.5 mm for polar trace.
GENERAL
Sweep Output -5 V to +5 V
External Sweep Inputs 0 to 10 V nominal
X-Y Recorder/External CRT Output
Horizontal and Vertical 0.1 V/div
Penlift/Blanking +5 V Blanking and Penlift
External Marker Input typically -13 dBm RF signal produce a marker at the frequency of the RF signal
Magnitude/Phase Output -10 mV/degree and -100 mV/dB
Probe Power Two +15 Vdc and -12.6 Vdc
Storage-Normalizer Interfaces Directly compatible with the HP 8750A Storage-Normalizer.  HP 8501A Storage-Normalizer requires a single internal adjustment for compatibility.
Programming Connector Outputs include magnitude/phase and sweep outputs and inputs described above as well as measurement mode and selection by TTL levels or contact closures.
External Source The HP 8754A sweep-out voltage is provided to frequency modulate (sweep) an external signal generator for narrowband measurement applications.  A sweep input is provided to synchronize the CRT display for use with an externally swept source (HP 8620 and 8350 series).
Temperature Operating: 0° to 55°C except where noted
Storage: -40°C to +75°C
EMI VDE 0871/0875 and CISPR publication 11.
Safety Conforms to the requirements of IEC 348.
Power Selection of 100, 120, 220, and 240 V +5% -10%. 48 to 66 Hz, 20 VA max.
Size 425.5 mm W X 133 mm H X 505 mm D (16 3/4" X 5 1/4" X 19 7/8")
Weight net, 16.8 kg (37 lb); shipping, 19 kg (42 lb)
 

Used Equipment Catalog

$20.00 Minimum on Total Order

Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________

99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:

Copyright © Fotronic Corporation All Rights Reserved