| SOURCE | |
| Frequency Characteristics | |
| Range | 300 kHz to 1.3 GHz (Option 003: 300 kHz to 3 GHz) |
| Resolution | 1 Hz |
| Accuracy | ± 10 ppm |
| Output Characteristics | |
| Power Range | -20 to +5 dBm |
| Resolution | 0.1 dB |
| Flatness | < 2 dB P-P |
| Level Accuracy (50 MHz, -5 dBm) | ± 0.5 dB |
| Level Linearity (relative to -5 dBm) | -20 to -15 dBm: ± 0.5 dB -15 to 0 dBm: ± 0.2 dB 0 to +5 dBm: ± 0.5 dB |
| Impedance | 50 Ω |
| RECEIVER | |
| Frequency Range | 300 kHz to 1.3 GHz (Option 003: 300 kHz to 3 GHz) |
| Noise Level | reflection -85 dBm (typical) Transmission -100 dBm |
| Maximum Input Level | 0 dBm |
| Impedance | 50 Ω |
| Crosstalk | (300 kHz to 1.3 GHz) 100 dB (1.3 to 3 GHz) 90 dB |
| Dynamic Accuracy | ± 0.05 dB, ± 0.3° over a 50 dB input range |
| Delay Characteristics | |
| Range | 1/(2* minimum aperture) |
| Aperture (selectable) | frequency span/(points-1) to 20% of the frequency span |
| Accuracy | (phase accuracy)/(360* aperture) |
| PHYSICAL CHARACTERISTICS | |
| Size | 178 H X 425 W X 482 mmD (7.0" X 16.75" X 20.0") |
| Weight | net, 22 kg (481 lb); shipping, 25 kg (55 lb) |
| UPGRADE KITS | |
| The following upgrade kits add optional measurement capability to existing 8752A network analyzers. | |
| 11885A 3 GHz frequency upgrade | The 11885A upgrade kit extends the operating frequency range of the 8752A from 1.3 GHz to 3 GHz. |
| 85019C time domain upgrade kit | The 85019C upgrade kit adds time domain analysis capability (Option 010) to an existing 8752A network analyzer. This kit is user-installable. |
| ACCESSORIES | |
| 11878A adapter kit | The 11878A adapter kit provides the RF components generally required when a SMA or 3.5 mm device needs to be measured with the 8752A standard type N configuration. The kit includes four type N to 3.5 mm adapters to accomodate both male and female connectors. |
| Test port return cable (8120-4781) | Hewlett Packard supplies a 610 mm (24 in) 50 Ω type N RF cable with every 8752A. Additional or replacement cables can be ordered separately. |
| 11852B 50 Ω/75 Ω minimum loss pad | The 11852B is a low SWR minimum loss pad required when measurements are made on 75 Ω devices with the 8752A network analyzer. Measurements on two port devices require two 11852Bs and one 50 Ω type N barrel. |
| Frequency Range | dc to 2.0 GHz |
| Insertion Loss | 5.7 dB |
| Return Loss | 75 Ω typically > 30 dB, 50 Ω typically > 26 dB |
| Connectors | 50 Ω type N female and 75 Ω type N male |
$20.00 Minimum on Total Order