Logic Analyzers Specifications

MEMORY
Data acquisition 1024 words
Compare 16 words, HP 1630A/D, 1631A/D; 16 or 1024 words, HP 1630G
Memory search all patterns within a label set may be marked or separately displayed
STATE ANALYSIS MODE
Clocks
Clock edges for each of three ORed clocks, select either or both edges; separate edges of one clock may be selected for multiplexed modes
Repetition rate, single phase 25 MHz for single edge of single clock; 20 MHz for any combinations of ORed clocks and edges
Repetition rate, multiplexed master clock must follow slave clock by at least 10 ns and precede next slave clock by at least 50 ns.
Pulse width ± 10 ns at threshold
Setup time ± 20 ns
Hold time zero
Data Indexing
Resources four terms, including the Boolean NOT of each term, ALL patterns or NO pattern; terms may be used as often as needed
Trigger up to four resource terms in sequence; final sequence term may use up to four ORed resource terms
Restart up to four ORed terms to reinitiate sequence search
Store qualifiers up to four ORed resource terms; may be separately defined for each term in the trigger sequence
Occurrence to 59,999; applies to final sequence term only
Compare width of analyzer by 16 words; trace until "equal to" or "not equal to" with each compare word matched to all 1024 words in memory; compare words may contain "don't care" items
Full compare (HP 1630G only) the compare file is the full 1024 states of memory
TIMING ANALYSIS MODE
Clock
Range 10 ns to 500 ms in 1, 2, 5 sequence
Accuracy ± 0.01%
Glitch min detectable glitch, 5 ns width at threshold; with glitch detection on, number of timing channels is halved
Data Indexing
Asynchronous pattern 20 ns to 1 ms in 1, 2, 5 sequence with accuracy ± 20% or 15 ns, whichever is greater; glitch or edge ANDed with asynchronous pattern
Maximum time delay approx. 218 times the sample period, to 9999 s max
Cursors time between dual cursors (x and o) displayed to accuracy of one sample period
Expansion X1 to X40 in 1, 2, 4 sequence; standard display shows entire 1 k memory at X1
ANALOG ANALYSIS MODE (HP 1630G)
Channel 1 and 2 (Vertical)
Probe factors 1:1, 10:1, or 50:1 probe attenuation factors may be entered to scale the HP 1631A/D to input voltages at the probe tip
Range 40 mV to 2.5 V full-scale
Bandwidth (-3dB) dc-coupled dc to 50 MHz
Dc gain accuracy ± 2.5% of full-scale
Analog-to-digital conversion (ADC) resolution ± LSB, which is ± 1.6% of full-scale
Transition time ± 5.25ns, 20% to 80% of full-scale
Trigger
Sources channel 1, channel 2, or external trigger input
Edge rising or falling edge may be selected for any source
Time Base (Horizontal)
Sample period 5 ns to 500 ms in a 1, 2, 5 sequence
Range 125 ns to 500 s full-scale (10 divisions)
Time base accuracy Sample period: ± .01%
Time-interval measurement accuracy (equal rise and fall times): single-shot, ± 1.5 ns for 5 ns sample period, ± 1 sample period for sample periods of 10 ns or greater; continuous, ± .15 times sample period, based on 100 averages
Delay tracepoint equals trigger plus delay; tracepoint can be delayed from 0 to about 260k sample periods after the trigger
ANALOG OPERATING CONDITIONS
Digitizer two channels are digitized simultaneously
Digitizing technique (real-time digitizing) all data points are digitized at equal selectable increments in time on each acquisition
Digitizing rate selectable, 2 samples/second to 200 megasamples/second
Voltage resolution 6 bits, 1 part in 64
Acquisition memory 1024 samples, 6 bits/channel, 2 channels; up to 1000 samples are used for display; magnifier allows full-screen display from 1000 samples to 25 samples; the entire 1024 sample record can be accessed via HP-IB and HP-IL.
INTERACTIVE STATE/TIMING/ANALOG ANALYSIS MODE
Acquisition analog, timing, and state data acquisition occur simultaneously
Arming either of the three analyzers can be master while the remaining two are slave
Master state the waveform analyzer and the timing analyzer can be simultaneously armed by the full data indexing capability of the state analyzer
Master timing the waveform analyzer and the state analyzer can be simultaneously armed by the full indexing capability of the timing analyzer
Master analog (HP 1631A/D) the timing analyzer and the state analyzer can be simultaneously armed by the full analog indexing capability of the waveform analyzer
Tracepoint alignment analog, timing, and state acquisition data can be correlated in time
Mixed display timing channels can be displayed on the same screen with analog channels; the tracepoint and time/div are common to timing and analog in this display mode, and set by the timing analyzer
SOFTWARE PERFORMANCE ANALYSIS AND OVERVIEW MODES
XY Chart all 1024 events/samples for any label group can be displayed as a chart of order of occurrence by magnitude; max and min vertical limits are user-specified
Time interval histogram measures time between start and stop events defined for up to eight time ranges
Time range min size, 1ms
Display histogram; min, max, average, and last time reading; total elapsed time; number of samples
Resolution for four-bit label group, 250 ns or 0.1% of reading, whichever is greater
State histogram sampled occurrence count of events in a label group for up to eight total user-defined ranges or values
Max count 263-1
Resolution ± 0.01%
Time-positional histogram (HP 1630G only) shows the number of occurrences of an event over time. A time unit is defined, and the analyzer counts the occurrences of a specified event in that time unit.  The measurement can be repeated for up to 1023 equal-sized time units.
Typical accuracy of first time unit -250 ns to +500 ns, ±0.01% of specified width
Typical accuracy of subsequent time units ±0.01% of specified width
Linkage histogram (HP 1630G only) shows up to eight module links. A link is defined as a specific state followed immediately by another specific state with no intervening states.  Store qualification can be used to acquire states selectively.  The measurement can be started on completion of a sequence of up to three resource terms, with restart and occurrence capabilities such as data indexing.
Max number of definable events 8
Max number of definable links 8
Max count 263-1
MEASUREMENT AIDS
Cursors two cursors (X and O) are provided for making voltage and time measurements on displayed waveforms. Both absolute and differential values are provided for voltage measurements.  Dual cursor time measurements can be made between two points on the same waveform or between two points on different waveforms.
Cursor statistics X to O cursor statistics are provided for continuous voltage and time measurements: max, min, mean and standard deviation.  Single cursor voltage statistics can be obtained between two points on the same waveform or between two points on different waveforms (time only).
Cursor placement both X and O cursors can be uniquely specified with respect to the tracepoint or acquisition start, by selection of channel 1 or 2, rising or falling edge, voltage level, hold or delay time.
STATE/TIMING/ANALOG INPUTS
State/Timing Probe Inputs
RC 100k ohm, ± 2% shunted by approximately 5 pFat at probe body
Minimum swing 600 mV p-p
Minimum input overdrive (above pod threshold) 250 mV or 30% of input amplitude, whichever is greater
Maximum voltage ± 40 V, peak
Threshold voltage ± -9.9 V to +9.9 V in 0.1 V increments
Accuracy 2.5%, ± 120 mV
Dynamic range ± 10 V about threshold
Analog Inputs (HP 1631A/D) channel 1, channel 2, external trigger
Internal coupling dc
Input RC 1 megaohm, ± 2% shunted by approximately 14 pF
Maximum safe input voltage ± 40 V (dc + peak ac)
GENERAL CHARACTERISTICS
Labels
Input channel labels up to eight state, up to 16 timing, user-defined, five-character labels may be assigned bit patterns in any configuration up to 65 (HP 1630G) bits/label. Bits may be used in more than one label and need not be contiguous.
User field all labels with four bits or less allow mnemonics to be assigned to specific patterns.  Primary use is to identify such functions as read, write, opcode, etc.
Relocatable field up to sixteen module starting locations may be specified, allowing trigger parameters to be based on module names, plus an offset value.
Time-of-day clock a 24-hour clock prints out the time of data collection on all stored records.
Activity markers provided in the format display for identifying active inputs
Non-volatile memory (HP 1630G) the HP 1630G has 8k of EEPROM for internally storing a disassembler. One setup configuration of the instrument can also be stored.
HP-IB Outputs An HP-IB connector, along with an eight-position switch, is located on the rear panel. Five positions are used to determine "talk-only" for hardcopy and system controller modes.
HP-IL Outputs An HP-IL connector is located on the rear panel for interfacing
Programmability All instrument configurations and acquisition data may be remotely programmed via the HP-IB (IEEE-488) or HP-IL.
Rear-panel BNC Outputs One BNC output is located on the rear panel with a TTL output. High is 2 V into 50 ohms; low is 0.4 V into 50 ohms. The BNC can be programmed from the keyboard to provide the following signals: pulse on state tracepoint, high until state tracepoint, low until state timing pattern, probe compensation (HP 1631A/D), and positive edge on analog trigger (HP 1631A/D). A second BNC is located on the rear panel to provide +5 V for the HP 10269B general-purpose probe interface.
OPERATING ENVIRONMENT
Temperature 0° to 55° C (+32° to 131°F)
Humidity up to 95% relative humidity at +40°C
Altitude to 4600 m (15,000 ft)
Vibration vibrated in three planes for 15 minutes each with 0.3 mm excursions, 5 to 55 Hz.
Weight all models ~30 lbs. (13.6 kg) net; all models ~40 lbs. (18.1 kg) shipping
Power 115/230 Vac, -22% to +10%; 300 Ω  max; 48-66 Hz
Size 190 X 426 X 447 mm (7.5 X 16.8 X 17.6 in)
ACCESSORIES SUPPLIED
One operating manual, one 2.3 m (7.5 ft) power cord, plus the following probes
HP Model # 10271A 10272A 10273A 10017A
1630A 3 1 - -
1630D 3 2 - -
1630G 3 1 3 -
1631A 3 1 - 2
1631D 3 2 - 2
 

Used Equipment Catalog

$20.00 Minimum on Total Order

Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________

99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:

Copyright © Fotronic Corporation All Rights Reserved