<< HP 4263B Product PageHewlett Packard 4263B
LCR Meter
Specifications
| Measurement Functions |
| Measurement Parameters |
|Z|, |Y|, q,
R, X, G, B, L, C, Q, D, ESR
Opt. 001: Add DCR (dc resistance), N (turns ratio), and M (mutual
inductance) measurement. |
| Measurement Circuit Mode |
Series and parallel |
| Mathematical Functions |
Deviation and percent deviation |
| Test Cable Lengths |
0 m, 1 m, 2 m, 4 m (freq. =
100/120/1k Hz); 0 m, 1 m, 2 m (freq. = 10k/20k Hz); 0 m, 1 m (freq.= 100
kHz) |
| Test Signal Information |
| Test Frequency |
100 Hz, 120 Hz, 1 kHz, 10 kHz, and
100 kHz
Opt. 002: Add 20 kHz test frequency |
| Frequency Accuracy |
±
0.01% (freq. = 100 Hz, 1 kHz, 10 kHz, (20 kHz, 100 kHz), ± 1% (freq. =
120 Hz) |
| Output Impedance |
100
Ω ±
10%, 25 Ω
± 10% (± 1 Ω range) |
| AC Test Signal Level |
20 m to 1 Vrms in 5m Vrms steps |
| Accuracy |
± (10%
+ 10 mV) |
| Internal dc Bias |
Level: 1.5 and 2 V
Accuracy: ± (5% + 2 mV) |
| External dc Bias |
0 to +2.5 V |
| Measurement Range |
Parameter |
Measurement Range |
| |Z|, R, X |
1 mΩ
to 100 MΩ |
| |Y|, G, B |
10 nS to 1000 S |
| C |
1 pF to 1 F |
| L |
10 nH to 100 kH |
| D |
0.0001 to 9.9999 |
| Q |
0.1 to 9999.9 |
| q |
-180° to +180° |
| DCR |
1 mΩ
to 100 MΩ |
| N |
0.9 to 200 (unspecified) |
| L, M |
1 µH to 100 H
(unspecified) |
| D% |
-999.99% to
+999.99% |
| Measurement Accuracy |
± 0.1%
(basic) (for |Z|, R, X, |Y|, G, B, C, L) |
| Measurement Time |
Mode |
Time (typical) |
| Short |
25 ms |
| Medium |
65 ms |
| Long |
500 ms |
| Test Signal Level Monitor |
Voltage and current |
| Front-End Protection |
Internal circuit protection when a
charged capacitor is connected to the input terminals. The maximum
capacitor voltage is: Vmax =
±/font>
(8/C) typical @ Vmax
± 250 V; Vmax =
± (2/C) typical @ Vmax
±
1000 V, C is in Farads. |
| Display Digits |
3, 4, or 5 (selectable) |
| Correction Function |
| Zero OPEN/SHORT |
Eliminates measurement errors due to
stray parasitic impedances in the test fixtures. |
| Load |
Improves measurement accuracy by
using a calibrated device as a reference. |
| Comparator Function |
HIGH/IN/LOW for each primary
measurement parameter and secondary measurement parameter. |
| Contact Check Function |
Contact failure between the test
fixture and device can be detected. Additional time for contact
check: 5 ms. |
| Other Functions |
| Save/Recall |
Ten instrument setups can be
saved/recalled from the internal nonvolatile memory. |
| Continuous Memory Capability |
If the instrument is turned off, or
if a power failure occurs, instrument settings (except dc bias on/off) are
automatically memorized (±
72 hours at 23° ± 5° C). |
| HP-IB Interface |
All control settings, measured
values, and comparator information. |
| Handler Interface |
All output signals are
negative-logic, optically isolated open collectors. Output signals
include HIGH/IN/LOW, no contact, index, end of measurement, and
alarm. Input signals include keylock and external trigger. |
| GENERAL SPECIFICATIONS |
| Power Requirements |
90 to 132 V or 198 to 264 V, 47 to 66
Hz, 45 VA max. |
| Operating Temperature |
0 to 45°C |
| Size |
320 mm W
X 100 mm H X 300 mm D (12.6 in X 3.94 in X 11.81 in) |
| Weight |
4.5 kg
(9.9 lb) |
| Key Literature |
HP 4263B
LCR Meter Product Overview, p/n 5964-6181E
LCR Meters, Impedance Analyzers and Test Fixtures Selection Guide, p/n
5952-1430 |
|