DSP-4000 Series Specifications
|
|
Cable
Types |
Shielded
and Unshielded Twisted Pair (STP and UTP) LAN Cabling:
- TIA
Category 3, 4, 5, 5E and 6: 100W
- ISO/IEC
Class C and D: 100W and 120W
Foil-Screened Twisted Pair (ScTP):
- TIA
Category 3, 4, 5, 5E and 6: 100W
- ISO/IEC
Class C and D: 100W and 120W
Shielded Twisted Pair (STP):
- 150W
IBM Type 1, 6, and 9(adapter required)
Coax:
- 10BASE5
ThickNet, 10BASE2 ThinNet, RG-58, RG-58 Foam, RG-59,
RG-59 Foam, RG-8, RG-8A/U, and RG-62
Fiber:
- Multimode
and singlemode fiber using fiber test accessories
|
|
Test
Standards |
- TIA
Category 3 and 5E per Addendum #5 to TIA/EIA-568A
- TIA
Category 5 (new) per TIA TSB-95
- TIA
Category 6 per TIA Addendum #1 to TIA/EIA-568B (draft)
- ISO/IEC
11801 Class C and D (new)
- ISO/IEC
11801-2000 Class C and D (new)
- STP
cabling, (IBM Type 1, 150 W)
- ANSI
TP-PMD
- IEEE
802.3 10BASE5, 10BASE2
- IEEE
802.3 10BASE-T, 100BASE-TX, 1000BASE-T
- IEEE
802.5
|
|
Speed
of Autotest |
Full
Autotest of Cat 5 UTP cable, including 6 pair combinations for
NEXT in both directions, in approximately 10 seconds. |
|
Supported
Tests |
(Range
of test is determined by network or selected standard)
NEXT, NEXT @ Remote
Wire Map
Characteristic Impedance
Length
DC Loop Resistance
Propagation Delay
Return Loss (RL), RL @ Remote
Delay Skew
Attenuation
Attenuation-to-Crosstalk Ratio (ACR), ACR @ Remote
Power Sum ACR, PSACR @ Remote
ELFEXT, ELFEXT @ Remote
Power Sum ELFEXT, PSELFEXT @ Remote
Power Sum NEXT, PSNEXT @ Remote |
|
LAN
Traffic |
- Monitor
provides an audible tone to indicate amount of traffic
- Monitors
10BASE-T Ethernet traffic using the Monitor RJ45 jack
- Monitors
100BASE-TX Ethernet traffic using the Monitor RJ45 jack
- Auto-negotiates
between 10BASE-T and 100BASE-TX using the Monitor RJ45
jack
- Blinks
the Link Light on a 10BASE-T, 10/100BASE-TX or a
100BASE-TX hub
|
|
Cable
Tone Generator |
Provides
a tone generator that can be detected by a handheld tone probe |
|
Display |
Graphic
bit-mapped LCD with back light and adjustable contrast |
|
Test
Connections |
Variable
(depending on Link Interface Adapter used) |
|
Input
Protection |
Protected
against continuous Telco voltages and 100 mA over-current.
Occasional ISDN over-voltages will not cause damage |
|
EMC |
EMC
compliant |
|
Case |
High
impact plastic with shock absorbing overmold |
|
Dimensions |
Main
unit and smart remote including link interface adapter:
11" x 5" x 3" (28 cm x 12.7 cm x 7.6 cm) |
|
Weight |
Main
unit: 3 lbs., 4 oz (1.5 kg)
Smart remote: 3 lbs., 1 oz (1.4 kg) |
|
Power |
Main
instrument and smart remote:
Rechargeable NiMH battery 7.2V, 3400 mAH
Typical battery life 10-12 hours, with recharge time of 4 hours
May be charged while in the instrument (while operating or
off-line) |
|
Languages
Supported |
English,
French, German, Spanish, Italian, Portuguese, Japanese, and
Simplified Chinese |
|
Calibration |
Service
center calibration period is 1 year. Self-calibration required
every 30 days. |