| Specifications |
| Function |
Description |
| Output |
030V/5Ax2 |
Constant voltage operation |
Line Regulation |
≤0.01% + 3mV |
| Load Regulation |
≤0.02% + 5mV |
| Recovery time |
≤100us |
| Ripple & Noise |
≤2mV rms |
| Temperature Coefficient |
≤300PPm/°C |
Constant Current
Operation |
Line Regulation |
≤0.2%+3mA |
| Load Regulation |
≤0.2%+3mA |
| Ripple & Noise |
≤6mArms |
| Tracking parallel |
Line Regulation |
≤0.01%+3mV |
| Load Regulation |
≤0.02%+10mV |
| Tracking serial |
Line Regulation |
≤0.01%+5mV |
| Load Regulation |
≤300mV |
| Positive and Negative
Supply |
Slave tracking error: ≤0.5%+10mV
of the master (No load. With load, add load
regulation ≤300mV) |
| CH3 output |
Regulation |
Line regulation ≤25mV, Load
Regulation ≤25mV |
| Ripple & Noise |
≤2mVrms |
| Output
Voltage |
2.5V, 3.3V,
5V (selectable), ±8% |
| Output Current |
3A |
| Protection |
Over voltage, over current,
overload, over temperature, current limit, short
circuit and reverser polarity protections. |
|
Insulation |
Between base and output terminal ≥20M/500V DC |
|
Between base and power cord ≥30M/500V DC |
| Display |
Ammeter |
3.20A full scale, 3 digits
0.5"LED display |
| Voltmeter |
32.0V full scale, 3 digits 0.5" LED display |
| Display resolution |
Voltmeter: 100mV Ammeter: 10mA |
| Saving accuracy |
V: ±(0.5% of reading + 2 digits) |
| A: ±(0.5% of reading + 5 digits) |
| Readback accuracy |
V: ±(0.5% of reading + 2 digits) |
| A: ±(0.5% of reading + 5 digits) |