<< UEI Catalog
<< UEI Automotive

UEi AGA5000
Five Gas Emissions Analyzer- Three in One,
Discontinued

 
Features:
  • Carbon Monoxide (CO) Hydrocarbons (HC), Carbon Dioxide (CO2), Oxygen (O2) and Nitric Oxide (NOX)
  • Measures five gases individually (actual, not calculated)
  • Infrared link to optional portable printer
  • Ruggedized design sets unsurpassed accuracy and durability standards for a hand-held instrument
  • Programmed to evaluate gasoline, LPG and CNG fuels
  • Includes protective rubber boot, water trap and filter, carry case, battery charger, exhaust probe and five extra filters
Click here for a larger image - UEI AGA5000 Five Gas Emissions AnalyzerClick here for a larger image - UEI AGA5000 Five Gas Emissions Analyzer
UEI AGA5000 Shown

Product Information
Datasheet 312 KB PDF
Click here for Information Regarding PDF'sPDF Help
 
The AGA5000 is truly portable exhaust gas analyzer that sets new standards of convenience and ease of use. It fits comfortably in one hand and can run for up to four hours on its internal re-chargeable battery.

Programmable four or eight line backlit display shows measurements in real time. The AGA5000 is made for additional uses which include engine fault diagnosis and tune-up verification. Integral flow checking provides warning of probe or filter blockages.

The calibration procedure allows the unit to be calibrated using standard automotive test gases. One year limited warranty.
 
Specification AGA5000
Gas Resolution Accuracy Range
CO 0.01% ±5% of reading
±0.5% volume
0-5%
Over-range 20%
O2 0.01% ±5% of reading
±0.1% volume
0-21%
Over-range 25%
HC 1 ppm ±5% of reading
±12 ppm volume
0-2000 ppm
Over-range 10,000 ppm
NOX 1 ppm ±5% of reading
±40 ppm volume
0-5000 ppm
Over-range 5,000 ppm
CO2 0.1% ±5% of reading
±0.5% volume
0-16%
Over-range 20%
Lambda 0.001 - 0.8-1.2
AFR 00.01 - 11.76-17.64
Sensor response time 15 seconds
Pre-programmed fuels Gasoline, LPG and CNG
Ambient operating range +41°F to 104°F / 10% to 90% RH non condensing
Hose length 12’
Battery charger Input: 110V AC, Output: 10V AC off load
Analyzer battery run time > 4 hours from full charge with pump running
 
Ordering Information
Model  Description Buy Online Price
AGA5000 UEI AGA5000 Analyzer, Automotive 5 Gas Discontinued