Transmation 1048

DC Process Signal Calibrator

1048
1048

Transmation 1048

DC Process Signal Calibrator

1048
1048
  • Calibrates all milliamp instruments
  • Calibrates voltage instruments
  • Rubber boot for protection in the plant
Replaced with:
PIE 850 Multifunction Process Calibrator with Loop Diagnostics, 10-50 mA
Practical Instrument 850
Multifunction Process Calibrator with Loop Diagnostics, 10-50 mA
  • Calibrates all milliamp instruments
  • Calibrates voltage instruments
  • Rubber boot for protection in the plant
  • One touch to set the output & function
  • Accuracy to ±0.015%
  • Four “AA” Alkaline cells for easy replacement
  • Nine setpoints for each range
  • Milliamp or percent display

Transmation 1048 DC Process Signal Calibrator .

Easy to use: The Transmation 1048 DC Process Signal Calibrator will check, calibrate and measure all your current signal instruments in a 4 to 20 or 10 to 50 milliamp loop plus source and measure DC Volts.

Use at every point in your loop. Source & read 0.00 to52.00 mA, simulate a 2-wire transmitter or use the 1048to supply loop power while measuring your 2-wiretransmitters. Toggle the display to show milliamps or percent span.

Source milliamps: Stroke valves, calibrate recorders and digital indicators or any other instruments that get their input from a 4 to 20 or10 to 50 mA loop. Easily set any value to within 0.01 mA with the numeric keypad.

Source millivolts and volts: Calibrate recorders, analyzers and other instruments with 0 to 100 mV, 0 to 1, 1 to 5 or 0 to 10 Volt inputs. Easily set any value to within 0.01 mV or 0.001V with the numeric keypad.

Recall output settings: Transmation 1048 DC Process Signal Calibrator easily stores up to nine setpoints per range. Instantly change the output by recalling any stored setpoint.

Fast output stepping: Automatically step through some or all of the nine stored setpoints with dwell time from 5 to 500 seconds. Plus manual stepping for full control during instrument calibration.

Calibrate using loop power: Check loop wiring and receivers by using the Model 1048 in place of a 2-wire transmitter. Simulate a changing process input to check loop response and control settings.

Read loop current: Check controller outputs or measure the milliamp signal anywhere in the loop. The Transmation 1048 DC Process Signal Calibrator measures 0.00 to52.00 mA signals with much greater accuracy than a typical multimeter. Toggle the display to show milliamps or percent of span. Power and measure 2-wire transmitters Simultaneously measure the output of a 2-wire transmitter while using the internal loop supply to power the transmitter. Handy for checking transmitters in the field or on the bench.

Read millivolts and volts: Transmation 1048 DC Process Signal Calibrator checks loop power supplies, batteries or any DC voltage in the plant from 0.00 to 90.00 mV, 0.000 to 20.000 V and 0.00 to 48.00 V.

More Information
BrandTransmation
ConditionNEW
UPC095969233804
Vendor Alias1048
  • 1 - Pair of test leads with banana plugs and alligator clips
  • 1 - Rubber Boot