Test Equipment Depot Top Nav Bar
Test Equipment Depot - 800.517.8431 Free Ground Shipping Offer
<< Sencore Catalog
 

Sencore SLM 1456
Signal Level Handheld Meter
Discontinued

 
  • All Channel/Frequency Tuning: From 5 to 870 MHz; allows you to test return path signals and up to your highest channel or frequencies with ease
  • Auto-Attenuation: from -40dBmV to +60 dBmV for full signal measuring capabilities
  • Analog Signal Measurements: That Include signal level, audio-to-video ratio, and carrier-to-noise for full analog signal analyzing.
  • Digital Signal Measurements: That include: Average peak power, MER, bBER, and constellation. Includes digital signal demodulation for QAM 16, 32, 64, and 256, plus demodulates 8 VSB Broadcast signals. Includes constellation display
  • Signal leakage: Testing capabilities with audible tone, leakage, level adjustment, and adjustable threshold
  • Ingress testing capabilities: Test both forward and return paths for unwanted noise
  • Full featured spectral display: provides the user with a complete channel spectrum, or bar display for quick review of all carriers to verify if one is missing. Plus, a quick and easy tilt
  • Datalogger system: Allows the user to save and print all data for future reference or drop point comparisons
Click here for a larger image - Sencore SLM 1456 Signal Level Analyzer/channelizerClick here for a larger image - Sencore SLM 1456
Sencore SLM 1456
Shown
Product Information
Datasheet 1.04 MB PDF
Specifications Sencore SLM 1456 Specifications
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information
Click here for Information Regarding PDF'sPDF Help
 
Today's cable systems have changed dramatically. In fact, they are no longer just cable systems, they are broadband cable networks featuring HD Video programming, high-end audio, high-speed data, and telephony. All this new technology requires more sophisticated, more detailed methods of testing by maintenance techs and installation techs. The New SLM 1456 from Sencore answers these needs by providing complete measurement for both analog and digital signals.
 
Features
Spectral Display
Single Channel Display It is often a necessity to look at a single channel spectrum display and look for interference. The Sencore SLM-1456 allows you to tune to a signal 6MHz channel anywhere in the 5 - 870 MHz band and to display a full spectrum view of that channel
Full Spectral Display Many technicians also want to see a spectral view of all the frequencies on a display so they can see if there is interference between the carriers. Some also like a quick glance to look at system balance or just to verify that all the carriers are present. The Sencore SLM-14-56 Full spectral Display allows you to view your full channel line up or a specific channel or frequency for quick and accurate signal troubleshooting and verification, including the sub-band reverse path.
Troubleshoot RF Simple and easy to understand displays for both analog and digital signal parameters provide you with all the information you need to troubleshoot and analyzes RD signals. Includes Level, C/N, and A/V Ratio)
Digital Signals
Digital Measurements Digital has become a buzz word in the industry, But digital cal mean many different type of signals available on today cable networks: QAM, used in several different digital formats that could include 16, 32, 64, or 256/ QPSK is used in the return side of the hi-speed cable and even 8VSB (typically used by offair broadcasters for HD signals.). A cable system could include any of these "digital" signals.

To truly test and troubleshoot digital signals you need to measure several parameters including:
- Average peak power
- BER
- MER or SNR
- Constellation
Ingress measurement
System
Ingress
Having the ability to test both signal and digital parameters is very important in providing a good clean signal to the subscriber, but there is another area that has always been important and, with the advent f digital signals, had come to the forefront: System ingress.
Ingress can cause ghosting, co-channel and a variety of other problems with the typical analog signal. But with digital signals, ingress could mean a complete loss of picture. A Large portion of ingress type problems come directly from the subscriber's side of the drop. Operators are recognizing this face, and have begun to require all technicians and installers to test for system ingress. In other to provide a quality digital signal to the subscriber, testing for ingress has become a must in the industry.
Analog Signals
Analog Measurements Most Cable systems still provide basic RF signals. Infact a majoty of the programming that is available is still analog, or at least being provided in analog at this point. Advanced analog testing is still vital to ever cable system.

The Sencore SLM 1456 includes the following measurements:
- Video Level
- Audio Level
- C/N
- A/V Ratio
 
Specifications
Automatic/Manual Spectrum Analysis
Frequency Range 5-870 MHz
Dynamic Range >60dB
Resolution Bandwidth 100KHz
Reference Level TV from 10dBuV to 125BuV
Marker Frequency 5-870MHz
Marker Analog Or Digital Automatic
Bar Scan From 19 to 120 Channels (selectable)
Storage of bar scan Up to 20 pictures
Analog Measurements
Frequency Band TV and Radio 5 - 870MHz
Frequency Resolution 62.5KHz
Input Impedance 75 Ohms
Dynamic Range measurement 15 dBuV to 125dBuV
or -45 to +65Bmv
or -98 to +16dBm
Measurement resolution 0.1dB
Level Measurement Accuracy 1dB Typical (2dB max)
A/V Ratio 1.5dB Typical (2dB max)
C/N Ratio 2dB Typical (2dB Max)
Measurement filter
bandwidth
600 memory positions
Digital Measurement
Frequency Band 47 - 870 MHz
Power measurement:
dynamic range
From -35 to 56 dBmV
BER
Measurement
General dBER up to 1x10-8
After Reed–Solomon
error correction
aBER up to 2x10-9
MER measurement 17 dB to 36 dB
Constellation display 64-128-256 (on graphics display)
General Specifications 
Voltmeter
function
AC (square wave), DC, 0 to 100V
Channel plan master
copy function
Optional VIA PC
Power supply Type Built-in NI-CD Rechargeable battery
External Power Supply 17 VAC or 20 VDC, 1A
Adapter 120V AC/DC Adapter
Battery Duration at 25°C 4 - 6 hours in analog mode
3 - 4 Hours in Digital Mode
Physical
Specifications
Size (H x W x D) 11.8" x 4.33" x 2.36"
Weight 2.7 LBs
Download port RS-232 Standard serial Port
Display 128 x 128 pixels, 2.5" Square
 
Ordering Information
Model Description Buy Online Price
SLM1456 Sencore SLM 1456 Signal Level Analyzer DISCONTINUED  Discontinued
Included Accessories
 
  • 1 - 12 V AC/DC adaptor
  • 1 - USB 2.0 cable
Included
Back to top >>
 

Sencore Catalog   |   Sencore Price List

$40.00 Minimum on Total Order