SBS SBS-4830S

Constant Current DC Load Bank, 24VDC 150A / 48VDC 300A

SBS4830S
SBS-4830S

SBS SBS-4830S

Constant Current DC Load Bank, 24VDC 150A / 48VDC 300A

SBS4830S
SBS-4830S

The Storage Battery Systems SBS-4830S is a DC Load Bank that discharge tests and load tests stationary batteries. It performs accurate IEEE450, IEEE1106 and IEEE1188 load tests without adjusting the current. It displays the voltage, current and Ah removed from the string. With multiple adjustable stop points, the built-in protection prevents battery damage due to over-discharging.

  • 24V DC 0-150 Amp / 48V DC 0-300 Amp
  • Test parameters adjustable without stopping test
$6,995.00 Price $8,745.00
This item ships FREE
  • 24V DC 0-150 Amp / 48V DC 0-300 Amp
  • Perform IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests
  • Automatically discharges batteries unmanned without danger of over-discharging
  • Continuously holds the current set throughout the test
  • LCD screen displays real time voltage, discharge current and capacity/Ah removed
  • Test parameters adjustable during test without stopping test
  • 3 adjustable stop points for built-in protection: end system voltage, test time, and capacity discharged
  • Units can be slaved with the SBS-8400 and/or other load banks to increase amp draw
  • Built-in protections: Over load protection, high voltage shutdown, high temperature shutdown, audible alarm, warning on LCD screen

The Storage Battery Systems SBS-4830S DC Load Bank 24V DC 0-150 Amp/ 48V DC 0-300 Amp discharge tests and load tests stationary batteries as recommended. NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five(5) years and VRLA batteries every 12-18 months. The SBS-4830S is an affordable way to perform easy and accurate IEEE450 (vented lead acid), IEEE1106 (NiCd) and IEEE1188 (VRLA) load tests.

Displays the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test. These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge.

More Information
Country of OriginChina
BrandStorage Battery Systems
ConditionNEW
Vendor AliasSBS-4830S
  • 2 - 9FT DC Cables
  • 1 - Carrying Case with Wheels
  • 1 - User Manual