Constant Current DC Load Bank 125V DC, 0-300A

SBS1230S
SBS-1230S

SBS SBS-1230S

Constant Current DC Load Bank 125V DC, 0-300A

SBS1230S
SBS-1230S

The Storage Battery Systems SBS-1203S is a DC Load Bank that discharge tests and load tests stationary batteries. The constant current load bank performs accurate IEEE450, IEEE1106 and IEEE1188 load tests without the need to adjust the current. It displays the voltage, current and Ah removed from the string. With multiple adjustable stop points, the built-in protections prevent battery damage due to over-discharging.

  • 125V DC 0-300 Amp
  • 3 adjustable test parameters
$8,995.00 Price $11,245.00
This item ships FREE
  • 125V DC 0-300 Amp
  • Perform IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests
  • Automatically discharges batteries unmanned without danger of over-discharging
  • Continuously holds the current set throughout the test
  • LCD screen displays real time voltage, discharge current and capacity/Ah removed
  • Test parameters adjustable during test
  • 3 adjustable test parameters: end system voltage, test time, and capacity discharged
  • 3 adjustable stop points: end system voltage, discharge time, discharge capacity
  • Units can be slaved with the SBS-8400 and/or other load banks to increase amp draw
  • Built-in protections: Over load protection, high voltage shutdown, high temperature shutdown, audible alarm, warning on LCD screen

The Storage Battery Systems SBS-1203S DC Load Bank 125V DC 0-300 Amp discharge tests and load tests stationary batteries as recommended. NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5 )years and VRLA batteries every 12-18 months. The SBS-1230S constant current load banks are an easy and affordable way to perform accurate IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests.

THe SBS1203S displays the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test. These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge. Automatically discharges batteries unmanned without danger of over-discharging.

More Information
Country of OriginChina
BrandStorage Battery Systems
ConditionNEW
Vendor AliasSBS-1230S
  • 2 - 9FT DC Cables
  • 1 - Carrying Case with Wheels
  • 1 - User Manual