Practical Instrument 830-RW

Multifunction Diagnostic Process Calibrator with Dual Display and Replacement Warranty

830PIECALRW
830-RW

Practical Instrument 830-RW

Multifunction Diagnostic Process Calibrator with Dual Display and Replacement Warranty

830PIECALRW
830-RW
  • 3 year repair warranty
  • Lighten up your toolbox
  • Technician-friendly operation
Replaced with:
PIE 830 High Accuracy Multifunction Diagnostic Process Calibrator with Dual Display
Practical Instrument 830
High Accuracy Multifunction Diagnostic Process Calibrator with Dual Display
  • 3 year repair warranty
  • Lighten up your toolbox
  • Technician-friendly operation
  • Multifunction calibrator: use it as a milliamp, voltage, frequency, RTD and resistance calibrator
  • Detect 'hidden' loop problems
  • Automatically detect 2, 3 or 4 wire RTDs
  • First multifunction calibrator with three troubleshooting tools
  • Calibrate 2 wire transmitters
  • Measure temperature sensors, frequency pickups, loop currents and voltage levels
  • Accurate to ≤ ± (0.02 % of Reading + 0.01% Full Scale)
  • Simulate pH probes & calibrate pH transmitters
  • Calibrate directly in temperature to 0.1°C & 0.1°F
  • Checkout flow & vibration systems
  • Evolutionary design
  • Easy to read
  • Quickly set any three outputs plus automatic stepping & ramping
  • Measure temperature sensors, frequency pickups, loop currents, voltage levels & pressures

The Practical Instrument Electronics (PIE) PIECAL 830 High Accuracy Multifunction Diagnostic Process Calibrator with Dual Display can carry eight single function calibrators plus a milliamp calibrator with loop supply in the palm of your hand! The Pie 830 multifunction calibrator with three troubleshooting tools; Detect 'hidden' loop problems, Quickly diagnose troublesome ground fault, and current leakage with patented Loop Diagnostic technology. The Pie 830 can automatically detect 2, 3 or 4 wire RTDs, troubleshoot sensor connections, and find broken wires with patented technology.

pH Simulator - Simulate pH probes into transmitters & analyzers: The Pie 830's pH simulator to verify proper operation of pH devices before you place a probe into a calibrated buffer. Adjusting the pH transmitter or analyzer without a probe allows you to make sure the device is calibrated and doesn't require too much offset with the probe. If the Pie 830's probe requires more than the manufacturer's recommendations (typically 5%) it is time to replace the probe. The Pie 830 simulates 0.000 to 14.000 pH @ 25°C corresponding to -414.12 to +414.12 mV.

Troubleshoot Loop Problems: With the Piecal 830 Calibrator, the user can find current leaks in loops before swapping instruments. The Piecal 830 features Automatic indication Loop Current and Leakage Current (US Patent #7,248,058). Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges to help you decide if there is a wiring problem in the loop.

PIECAL 830-RW Multifunction Diagnostic Process Calibrator with Dual Display inluding Replacement Warranty

More Information
BrandPIE
ConditionNEW
Vendor Alias830RW
  • 1 - Blue Rubber Boot
  • 1 - Evolution Hands-Free Carrying Case (w/ Shoulder Strap)
  • 2 - Sets of Test Leads (w/ Spade Lugs for RTD and ohms)
  • 1 - Set of Test Leads (w/ Alligator Clips for Milliamp, Volt, Frequency, & Continuity)
  • 1 - NIST Traceable Calibration Report & Certificate
  • 1 - 3-Year Repair/Replacement Warranty