Picotest Catalog Picotest Price List xClose Window
   
Model U6200A
(Picotest)
53132A
(Agilent)
List Price $$1,750.00 $$4,282.00
Frequency 12 Digits / Sec. 12 Digits / Sec.
Frequency, Period 1mHz to
400 MHz
2.5 ns to
1000s
0.1 Hz to
225 MHz
4.44 ns to
10s
Voltage Range & Sensitivity 1mHz to 225 MHz 20 mVrms to ± 5V ac + dc 1mHz to 100 MHz 20 mVrms to ± 5V ac + dc
225 MHz to 400 MHz 30 mVrms to ± 5V ac + dc 100 MHz to 200 MHz 30 mVrms to ± 5V ac + dc
200 MHz to 225 MHz 40 mVrms to ± 5V ac + dc
Frequency Ratio 10E-10 to 10E+11 11 Digits / Sec. 10E-10 to 10E+11 8 Digits / Sec.
Time Interval -1.5 ns to 10E5 s 40 ps -1 ns to 10E5 s 150 ps
Phase -180° to + 360° -180° to + 360°
Duty Cycle 0 to 1 Pulse widths >
1 ns
0 to 1 Pulse widths >
4 ns
Rise / Fall Time 1.5 ns to 10E + 5 s 5 ns to 10E + 5 s
Pulse Width 1.5 ns to 10E + 5 s 5 ns to 10E + 5 s
Totalize 0 to 10E + 15 ± 1 count 0 to 10E + 15 ± 1 count
Trigger Level ± 5.125 V 2.5 mV ± 5.125 V 5 mV
Peak Volts
(1 Vp-p, 50 Ω, ATT OFF)
DC signals: 15 mV + 2% of V DC signals: 25 mV + 2% of V
100 Hz ~ 10 KHz 15 mV + 2% of V 100 Hz ~ 30 MHz 25 mV + 10% of V
10 KHz ~ 5 MHz 15 mV + 3.5% of V  
5 MHz ~ 80 MHz 15 mV + 6% of V  
80 MHz ~ 300 MHz 15 mV + 13% of V  
Peak Volt Mode Fast > 10 KHz Slow > 100 KHz Slow > 100 KHz
Time Base (Standard) (0° to 50°C) (Standard) (0° to 50°C)
Temperature Stability
(referenced to 25°C)
< 1 PPM < 5 PPM
Aging Rate
(after 1 year)
< 2 PPM  
Calibration Electronic Manual Adjust
Operating Environment 0° to 50°C 0° to 50°C
Remote Interface GPIB/USB/ Ethernet IEEE488.2/ USBTMC GPIB IEEE488.2
Damage Level 50 Ω 12 Vrms   50 Ω 5 Vrms  
1 MΩ (0 to 3.5 kHz, 350 VDC + AC pk) 1 MΩ (0 to 3.5 kHz, 350 VDC + AC pk)
1 MΩ (3.5 kHz to 100kHz)
350 VDC + AC pk linearly derated to 12 Vrms
1 MΩ (3.5 kHz to 100kHz)
350 VDC + AC pk linearly derated to 5 Vrms
1 MΩ > 100 kHz, 10 Vrms 1 MΩ > 100 kHz, 5 Vrms
Remote Programming Language SCPI-1992.0 Compatible with AXXX 53132 SCPI-1992.0  
Power Supply 100 to 240V 50 ~ 60 Hz
100 to 127 400 Hz
50 VA Max
100 to 129 VAC ± 10 % -50, 60 or
400 Hz ± 10 % 220 to 240 VAC
± 10 % -50 or 60 Hz ± 10 %
Front-End Isolation YES NO
Built-In CH3 YES (Standard) NO (Optional)
 

Specifications for the Built-In CH3

Power Range and Sensitivity
(Sinusoid)
375 MHz to 500 MHz -16 dBm to + 15 dBm
500 MHz to 1 GHz -20 dBm to + 15 dBm
1 GHz to 2 GHz -23 dBm to + 15 dBm
2 GHz to 4 GHz -25 dBm to + 15 dBm
4 GHz to 5 GHz -23 dBm to + 15 dBm
5 GHz to 5.5 GHz -20 dBm to + 15 dBm
5.5 GHz to 6 GHz -17 dBm to + 15 dBm
Damage Level

+ 25 dBm