Oakton Instruments WD-89800-02

TC9000 Standard Thermocouple Temperature Controller, 230 VAC

WD8980002
WD-89800-02
8980002

Oakton Instruments WD-89800-02

TC9000 Standard Thermocouple Temperature Controller, 230 VAC

WD8980002
WD-89800-02
8980002
  • Outlet receptacle allows for direct plug-in of heating devices such as hot plates, heat tapes, or mantles
  • Control type: on/off
  • Resolution: 0.1°; 1° above 999.9° and below -99.9°
Replaced with:
Digi-Sense 89800-12 TC9100 Benchtop Temperature Controller for Thermocouples, 230 VAC
DIGI-SENSE 89800-12
TC9100 Benchtop Temperature Controller for Thermocouples, 230 VAC
  • Outlet receptacle allows for direct plug-in of heating devices such as hot plates, heat tapes, or mantles
  • Control type: on/off
  • Resolution: 0.1°; 1° above 999.9° and below –99.9°
  • Accuracy: Types J, K, T, E, and N: ±0.1% of reading, ±0.7°F (0.4°C) above –248°F (–100°C); ±0.1% of reading, ±2°F (1°C) below –248°F (–100°C) Types B, R, and S: ±0.1% of reading, ±1.8°F (1.0°C)
  • Display: LCD
  • Operating ambient: 32 to 104°F (0 to 40°C); 0 to 90% RH, non-condensing
  • Control output: powered receptacle rated for 230 VAC, 10 A max

The Oakton WD-89800-02 Digi-Sense TC-9000 thermocouple temperature controllers can be used for a wide variety of applications including pilot process plants, R & D labs, or for OEM requirements. Rear panel output receptacle for direct plug-in of heaters and other resistive devices. Field calibrations help to improve system accuracy by entering the offset value to correct for individual probe error.

Simultaneously view both the measured and set point on the two-line alphanumeric display. Temperature scale selectable to read in° F, °C, K (Kelvin), or °R (Rankine). Front panel LEDs indicate output and alarm conditions.

The WD8980002 TC 9000 230 VAC model features an IEC cord set and universal receptacle. Built-in grid support bracket allows the unit to be mounted onto a laboratory frame or grid.

Safety features—Output power to load device is automatically shut down in the event of a broken sensor or control loop break. Overtemperature protection shuts down the system if the user-settable over-temperature or timer is exceeded. Outlet power receptacle is fused separately from the controller for added safety. Audible and visual out-of-range alarms are also included.

More Information
BrandOakton
Catalog8980002
ConditionNEW
Vendor AliasWD-89800-02
  • 1 - Grid support bracket
  • 1 - 6 ft. power cord with 240 V AC plug
  • 1 - Ferrite clip
  • 1 - User manual
  • 1 - Quick start guide