| Test Equipment Catalog | Specials | Repair | Surplus | Ordering/Contact Info |
|
|
| << Megger Megohmmeters / Insulation Testers |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Megger 212159, 212359, 212459, and 212559 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Megger 212159 Shown |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Quality is crafted into every Major MEGGER® Insulation Tester, with
excellent test voltage regulation, direct measurement readout and an
external guard terminal to eliminate surface leakage current from the
measurement. Five models are available for general purpose testing
which include a low-voltage model. All are portable, self-contained
instruments designed to give rapid and accurate measurements.
Four of the models feature an analog display having four selectable test voltages of 100, 250, 500 and 1000 VDC, measuring insulation resistance up to 2000 MΩ,and an ohm range to 5000 ≈. The other model has four test voltages of 50,100, 250 and 500 VDC measuring insulation resistance up to 1000 M≈.The only other difference between the five analog models is the type of power source. Power for models 212159 and 212160 is derived from a low-voltage, hand cranked generator which has been designed to be easy to turn even under full load conditions. The low-voltage generator is connected to an electronic inverter to provide a very stable test voltage. Accuracy of measurement is unaffected by variations in the generator cranking speed and the test voltage is maintained at its rated value. Power for model 212359 is provided by 120 V ac 50/60 Hz or low-voltage generator. Model 212559 is also 120 VAC 50/60 Hz or internal rechargeable batteries and model 212459 is powered by 6replaceable "AA" alkaline cells. As a safety feature, the ac voltage range becomes effective as soon as the instrument is connected to the circuit under test. Therefore, a warning is given that the circuit under testis not de-energized before the instrument is operated. Though calibrated for ac voltage, this range also monitors the automatic discharge feature so that after equipment having capacitance (i.e. a cable), has been tested, an indication can be given that the voltage has discharged to a level that is safe for removing the test leads. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Ordering Information | |||
| Model | Description | Buy Online | Price |
| 212159 | Megger 212159, Hand-Crank Analog Major Megger Insulation Tester; 100, 250, 500 & 1000 V; 2 GOhms |
|
Sale $1,015.95 (Reg. $1,069.00) |
| 212359 | Megger 212359, Hand-Crank/Line Analog Major Megger Insulation Tester; 100, 250, 500 & 1000 V; 2 GOhms |
|
Sale $1,091.95 (Reg. $1,149.00) |
| 212459 | Megger 212459 Battery Analog Major Megger Insulation Tester; 100, 250, 500 & 1000 V; 2 GOhms |
|
Sale $1,015.95 (Reg. $1,069.00) |
| 212559 | Megger 212559, Battery/Line Analog Major Megger Insulation Tester; 100, 250, 500 & 1000 V; 2 GOhms |
|
Sale $1,091.95 (Reg. $1,149.00) |
| Included Accessories | |||
|
Included | ||
| Replacement Accessories | |||
| 6220436 | Megger 6220-436, Set of 6 ft. Leads for 212160, 212159, 212359, 212459 & 212559 with aligator clips |
|
Sale $112.95 (Reg. $119.00) |
$40.00 Minimum on Total Order