Test Equipment Depot - 800.517.8431 McAfee Secure sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams

<< Kenwood Oscilloscopes

Kenwood CS-4125A and CS-4135A
Analog Oscilloscopes

  • X-Y Mode
  • Relay-type attenuators with long life and excellent operability are used.
  • One-touch ALT/CHOP switching
  • High reliability with Kenwood Original Hybrid ICs
  • One-touch TV sync
  • Relay-type attenuators with long life and excellent operability are used
  • FIX sync
  • Convenient VERT mode
  • Dynamic range with a headroom for accurate waveform display without distortion

Click here for a larger image of the Kenwood CS-4125AClick here for larger image
Kenwood CS-4125 Shown

Product Information
Datasheet 23 KB
Specifications HTMLClick to jump to...
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information

PDF Help

 
The CS-4100A Series with excellent cost efficiency were created from a fusion of performance, reliability, operability and design, and realize general-purpose characteristics which can be used in a variety of observations and inspections ranging from very small to very large signals.
 

SPECIFICATIONS

Model CS-4135A CS-4125A
CRT : Type 150mm rectangular with internal graticule
Accelerating voltage Approx. 12kV  Approx. 2kV
Effective area 8×10 div. (1div=10mm)
Vertical axis (Common for CH1, CH2)
Operating modes CH1, CH2, ADD, ALT, and CHOP
Sensitivity 1mV/div to 5V/div (1mV/div., 2mV/div.±5%, 5mV/div to 5V/div. ±3%) 
Attenuator 1-2-5 steps, 12 ranges, and fine adjustment

Frequency response

DC DC to 40MHz (-3dB) (5mV/div. to 5V/div.) DC to 20MHz (-3dB) (5mV/div. to 5V/div.)
DC to 5MHz (-3dB) (1mV/div. to 2mV/div.) DC to 5MHz (-3dB) (1mV/div. to 2mV/div.)
AC 10Hz to 40MHz (-3dB) (5mV/div. to 5V/div.) 10Hz to 20MHz (-3dB) (5mV/div. to 5V/div.)
10Hz to 5MHz (-3dB) (1mV/div. to 2mV/div.) 10Hz to 5MHz (-3dB) (1mV/div. to 2mV/div.)
Input impedance 1MΩ ±2%, Approx. 23pF
Rise time Approx. 8.75ns (40MHz) (5mV/div. to 5V/div.) Approx. 17.5ns (20MHz) (5mV/div. to 5V/div.)
Approx. 70ns (5MHz) (1mV/div to 2mV/div.) Approx. 70ns (5MHz) (1mV/div. to 2mV/div.)
Crosstalk Below -40dB (at 1kHz sine wave)
Polarity inversion CH2 only
Maximum input voltage 800V p-p or 400V (DC AC peak)
CHOP frequency Approx. 250kHz
Horizontal axis (CH2 input)
Operating modes Switch to X-Y on CH1 : Y-axis / CH2 : X-axis
Sensitivity Same as CH2 vertical axis
Input impedance Same as CH2 vertical axis
Frequency response DC : DC to 500kHz (-3dB) / AC : 10Hz to 500kHz (-3dB)
X-Y phase difference Within 3 degrees at 50kHz
Sweep : Sweep time 0.2µs/div. to 0.5s/div. ±3% 0.5µs/div. to 0.5s/div. ±3% (0.2µs/div. : UNCAL)
1-2-5 steps, 20 ranges, and fine adjustment
Magnified sweep (×10MAG) ×10, ±5% ×10, ±5% (0.2µs/div. : UNCAL) 
Linearity ±3%(×10MAG : ±5%) ±3% (0.2µs/div:UNCAL) (×10MAG : ±5%, 20ns/div. : UNCAL)
Triggering : Trigger sources VERT, CH1, CH2, LINE and EXT
Mode AUTO, NORM, FIX, TV-F and TV-L
Trigger coupling AC, TV-F and TV-L
NORM INT 10Hz to 20MHz 1.5div. 10Hz to 5MHz 1div.
EXT 0.25Vp-p 0.2Vp-p
INT 20MHz to 40MHz 2div. 5MHz to 20MHz 1.5div.
EXT 0.3Vp-p 0.3Vp-p
AUTO INT 50Hz to 20MHz 1.5div. 50Hz to 5MHz 1div.
EXT 0.25Vp-p 0.2Vp-p
INT 20MHz to 40MHz 2div. 5MHz to 20MHz 1.5div.
EXT 0.3Vp-p 0.3Vp-p
TV INT FRAME, LINE 1div. FRAME, LINE 1div.
EXT LINE 0.2Vp-p LINE 0.2Vp-p
FIX INT 50Hz to 40MHz 2div. 50Hz to 20MHz 2div.
EXT 0.5Vp-p 0.5Vp-p
External trigger : Input impedance 1MΩ, Approx. 23pF

Maximum input voltage

84V p-p or 42V (DC ACpeak)
Calibration voltage 1V p-p±3% (Square wave, 1kHz, positive polarity)
Intensity modulation : Input voltage TTL level (dark for positive voltage)
Input impedance Approx. 5kΩ
Frequency response DC to 3.5MHz
Maximum input voltage 84V p-p or 42V (DC AC peak)
CH1 Signal output
Output voltage Approx. 50mV/div. (loaded 50Ω)
Output impedance Approx. 50Ω
Frequency response 100Hz to 20MHz (within ±3dB, loaded 50Ω) 100Hz to 10MHz (within ±3dB, loaded 50Ω)
Trace rotation Enables trace rotation adjustment from front panel
Environmental condition 10°C to 35°C, 85% or less (temperature/humidity for characteristics in spec.)
Operation conditon 0°C to 40°C, 85% or less (temperature/humidity for operation)
Power source 100/120/220/230V AC ±10% (250V AC maximum), 50/60Hz
Power consumption 30W maximum
Case dimensions 290 (W)×150 (H)×390 (D) mm
Maximum dimensions 290 (W)×172 (H)×443 (D) mm
Weight Approx. 6.9kg Approx. 6.6kg
Accessories Instruction manual (1) / Probe (PC-54) (2) / Power cable (1)
 
Ordering Information

Model

Description BuyPrice
CS4125A  Kenwood CS-4125A 20 MHz Analog Oscilloscope Click to add item to cart Sale $492.42
(Reg. $566.00)
CS4135A  Kenwood CS-4135A 40 MHz Analog Oscilloscope Click to add item to cart Sale $838.68
(Reg. $964.00)
Included Accessories
 
  • 2 - PC-54 Probes
  • 1 - Power Cable
  • 1 - Instruction Manual

Included

Replacement Parts
PC54  Kenwood PC-54 Probe, 10:1/1:1 DC to 60 MHz Click to add item to cart Sale $43.50
(Reg. $50.00)
 

Kenwood Catalog   |   Kenwood Price List

$20.00 Minimum on Total Order