<< JDSU SMART Optical Loss Test Sets
JDSU ORL-55
Smart Optical Loss Test Set
|
-
High-precision ORL testing at 2 or 3 wavelengths (singlemode
1310, 1490, 1550, 1625 nm)
- Three instruments in one: return loss meter/power
meter/laser source
- TRIPLEtest function for simultaneous measurements at three
wavelengths in real time
- Auto-zeroing function (patent pending) for increased
measurement accuracy
- Internal data storage and PC software enables efficient
documentation and accurate reporting
- Built-in real-time clock
- Visual fault locator option at 635 nm
- Economical option for fiber
tracing, routing, and continuity checking
- Universal push-pull adapter
2.5 mm (1.25 mm adapter optional)
- Host USB data storage option
- Unlimited result storage
capacity via USB memory sticks
- Easy and quick data
transfer of stored measurement results
|
 
JDSU ORL-55 Series
Shown
|
With the world’s most complete portfolio of
more than 100,000 optical handhelds already in use, JDSU introduces a
new line of SMART optical handhelds to help your network graduate to the
next level of performance. JDSU’s SMART optical handhelds encompass a
new, intelligent, and next-level product line for testing all optical
signals and systems, including broadband, PONs, Gigabit Ethernet, and
CATV.
All of JDSU’s SMART optical handhelds provide:
- An extended number of calibration wavelengths for the highest
performance range in the industry.
- The SMARTStar graphical user interface for fast, easy, and
straightforward opera-tion.
- The SMARTEnergy power supply management system.
- The SMARTBag with neck strap allowing for the use of both hands
in the field.
- A USB port for remote operation as well as easy Microsoft®
Excel®-based report generation and analysis
- Traceable measurements to international standards for confidence
in accuracy
- A robust, shock-proof, and splash-proof design for field
operation
- Quick start operation, requiring no warm-up time and reducing
testing time.
- Four-way powering mechanism.
The JDSU ORL-55 Smart Optical Return Loss Meter is a high-performance,
easy-to-use instrument for field, laboratory, and production use. It
combines three different functions in one field-optimized instrument,
including an optical return loss meter, an optical power meter, and a
triple-wavelength laser source.
Three lasers with built-in optical isolators are combined to the angled
optical output (APC), providing easy return loss measurements without
the need of external normalization. High-precision fiber couplers and an
auto-zeroing function (patent pending) guarantee outstanding measurement
accuracy.
IJDSU’s TRIPLEtest function enables measurements at three wavelengths
simultaneous-ly by using sophisticated digital signal processing. The
results for all three wavelengths are shown simultaneously on a large
illuminated graphical display. This unique functional-ity reduces test
times by up to 70% and avoids inaccurate measurements from incorrect
instrument settings.
Internal data storage of up to 1000 results, including information about
date and time of the measurements, in conjunction with JDSU’s
complementary Optical Fiber Assistant Software (OFS-355), provide easy
documentation and test report generation. |
|
|
|
Specifications |
|
Function |
Descriptions |
|
Return loss meter |
|
Selectable
wavelength options |
1310 and 1550 nm |
1310/1490/1550 nm |
1310/1550/1625 nm |
|
Spectral width (RMS) |
<5 nm |
|
Measurement Range |
0 dB to 70 dB |
|
Measurement
accuracy |
± 0.7 dB (0 dB to
50 dB) |
| ± 0.9 dB (50 dB to
60 dB) |
|
Resolution |
0.01 dB |
|
Power meter |
|
Wavelength range |
1260 to 1650 nm
|
|
Calibrated wave-lengths |
Factory |
1310/1550/1625 nm |
|
User |
in 1
nm intervals from 1260 to 1650 nm |
|
Photo
Detector |
Germanium (GE) |
|
Display Modes |
dB/dBm/W |
|
Display
Range |
−70 to +20 dBm |
|
Maxiumum Input Level |
+6 dBm |
|
Resolution |
0.01 dB, 0.001 µW |
|
Measurement
accuracy |
± 0.4 dB |
|
Laser Source |
|
Selectable
wavelength options
|
1310 and 1550 nm |
1310/1490/1550 nm |
1310/1550/1625 nm |
|
Spectral width (RMS) |
<5 nm |
|
Maximum output
power |
−3 dBm |
|
Adjustable
attenuation |
0 to 7 dB |
|
Stability |
± 0.02 dB |
|
Operating
Modes |
Continuous wave (CW),
modulated (270 Hz, 1 kHz, 2 kHz), Auto-λ(5)
(signal coding for
automatic power meter wavelength detection) |
| Works only with
JDSU OLT-55 or an external OLP-55 power meter |
|
Source mode |
|
Data memory |
1000 measurement
results |
|
Data readout/remote control
|
via USB interface |
|
Modulation detection |
270
Hz, 1 kHz, 2 kHz |
|
Operating modes |
Continuous wave (CW),
modulation 270 Hz, 1 kHz, 2 kHz, Auto-lambda (λ) |
|
Memory |
|
Data memory |
1000 measurement
results |
|
Data readout/remote control
|
client USB
interface |
|
USB data storage (option)
|
via Host USB
interfacee |
|
| |