<< JDSU Catalog << JDSU Fiber Inspection and Test System |
JDSU FIT-HP2-80P4 High Power Integrated Fiber Inspection and Test Systems Display, integrated power meter and 400X patch cord microscope Discontinued |
| |
- 3.5-inch TFT LCD to view
clear, crisp, detailed images of fiber end faces with optimal
resolution
- Inspects both sides of fiber interconnect, and accurately
tests and measures optical power with one device
- Integrated functions and features eliminate switching
between multiple devices
- Input for FBP series probe microscope and a dedicated patch
cord microscope (PCM) let users quickly and easily inspect both
sides fiber interconnects
- Integrated PCM eliminates need for changing inspection
tips, prevents misrouting, and protects patch cords
- Integrated power meter (OLP-6/OLP-8) for all single-mode
and multimode applications, such as LAN, telecom, CATV, and DWDM
testing
- Modulation frequency detection lets users identify
individual fibers at specific tones
- Three-year calibration period
- Automatic wavelength detection (with JDSU optical light
source)
- GripSwitch™ power-save mode activates the display when held
in-hand and deactivates when released
|

JDSU HP2-80P4 Shown
|
|
|
| |
| The JDSU HP2 Series inspection and test systems combine fiber inspection and
optical power measurement into a single seamless handheld device. The result is a
significant increase in workflow efficiency with a system that is easy, repeatable, and
fast in performing essential tests in less than half the time it takes with other tools |
| |
| Specification HP2-80P4 |
| Display |
| Dimensions |
18.5 x 15 x 6.0 cm (7.3 x 5.9 x 2.4 in) |
| Weight |
760 g (26.8 oz) with eight AA alkaline batteries |
| Video display |
88.9 mm (3.5-in) TFT LCD |
| Connector |
4-pin Hirose input for FBP probes |
| Power source |
Eight AA batteries or AC power adapter (100–240 VAC/9V DC/500mA) |
| Power mode |
ON (continuous on) OFF GripSwitch (power save mode) |
| Horizontal field-of-view |
550 μm @ 200X 350 μm @ 400X |
| Power Meter |
| Display range |
–50 to +26 dBm |
| Max. permitted input level |
+27 dBm |
| Standard wavelength settings |
850, 980, 1300, 1310, 1490, 1550, 1625 nm |
| Calibrated wavelengths |
850, 1300, 1310, 1490, 1550, 1625 nm |
| Intrinsic uncertainty¹ |
±0.20 dB (±5%) |
| Linearity¹ |
±0.06 dB (-32 to +20 dBm) |
| Wavelength range |
780 to 1650 nm |
| Wavelength and modulation |
270 Hz, 330 Hz, 1 kHz, 2 kHz |
| 1300, 1310, 1490, 1550, 1625 nm |
–35 to +23 dBm |
| 850, 980 nm |
–30 to +23 dBm |
| Run Time |
~180 hours (continuous on) |
| Auto-shutoff Time |
5 minutes |
| Optical interface |
UPP 2.5 mm adapter (DIN, ST, FC, SC, E2000) UPP 1.25 mm adapter (LC, MU) - sold separately |
| Detector Type |
Germanium |
| Display |
LCD, 4-digit |
| Result display in |
dBm, dB |
| Resolution |
0.01 dB |
| 1 Under the following reference conditions: –20 dBm (CW), 1300 nm ±1 nm, 23°C ±3K, 45 to 75% relative humidity |
|
| |
| Ordering Information |
| Model |
Description |
Buy Online |
Price |
| FITHP280P4 |
JDSU FIT-HP2-80-P4 Handheld 3.5" display with integrated optical power meter and 200X Patch Cord Module |
Discontinued |
| Included Accessories |
| |
|
Included |
| Optional Accessories |
| FBPP5 |
JDSU FBP-P5 Probe Microscope. Analog Video Probe, 200/400X DualMag NTSC 4-Pin |
Discontinued |
| FITPUC2 |
JDSU FITP-UC2 Utility Carrier, for HD2/HP2, Hands Free System with Storage |
 |
Sale $99.95 (Reg. $105.00) |
|