Test Equipment Depot Top Nav Bar
Test Equipment Depot - 800.517.8431 Free Ground Shipping Offer
<< Hioki Catalog
<< Hioki Memory HiCorders

Hioki MR8880-20 Memory HiCorder
4 Channel Analog Fixed Input Memory Recorder

 
Click here for Larger Image = Hioki MR 8880-20 Memory HiCorderClick here for larger image
Hioki MR8880-20
(with MR9000) Shown
Product Information
Datasheet 3.5 MB PDF
Click here for Information Regarding PDF'sPDF Help
  • CAT III 600 V insulation performance
  • Direct input and measurement of 3-phase power lines
  • 4 analog + 8 logic channels
  • Directly input 600 V AC/DC (CAT III) and 300 V AC/DC (CAT IV) input.
  • Measure up to 2000V DC/1000V AC (CAT II) with the Differential Probe 9322 (separate power supply required.)
    • Maximum 600V AC/DC input - no need for a differential probe
    • 4 completely isolated channels let you simultaneously record data on a 3-phase power line plus have one extra channel
  • Tough against harsh environments
    • Operating temperature range: -10°C to 50°C
    • Even when operating on battery power, the Hioki MR8880-20 can take measurements from 0°C (32°F) to 40°C(104°F)
    • Built to withstand mechanical shocks and vibrations (ships standard with side protectors)
  • Built to withstand harsh environments
    • Extensive operating temperature range [-10°C (14°F) to -50°C(-58°F)]
    • Rugged, damage-resistant design features standard side protectors that guard the instrument’s case.
  • Measurement Applications
    • Plant equipment maintenance, inspections, and fault monitoring
    • Elevator maintenance, inspections, and fault monitoring
    • Train maintenance and inspections and rolling stock development
    • Automobile development, malfunction analysis, etc.
 

Engineered for use in extreme environments
Thanks to its safe, CAT III 600V class design, the Hioki MR8880-20 Memory HiCorder 4 Channel Analog Fixed Input Memory Recorder can directly measure high voltages of up to 600V at demanding plants and other facilities. The recorder also features an extended operating temperature range of -10°C to 50°C and complies with JIS automotive vibration standards, demonstrating its ability to withstand the harsh measurement environments associated with automotive development.

Measure 3-phase power lines thanks to standard 4 channels of input
The Hioki MR 888020 Memory HiCorder can perform isolated measurement using its 4 channels of analog input, allowing it to measure 3-phase power lines.

Simple operation with the PRESETS configuration navigator function
In the past, customer feedback has indicated that electrical measuring instruments are excessively difficult to configure and operate. The Hioki MR-8880 20’s PRESETS configuration navigator function addresses these concerns by allowing users to simply select an application—for example, measuring a commercial power supply or monitoring a line for a voltage drop—and follow the on-screen instructions to configure the instrument.

Print measurement data on-site with the optional printer
An optional A6-size printer can be used to print waveforms in the field, making it easier to hold effective evaluations at job sites. Data can also be stored in external storage media.

The Hioki MR8880-20 4 Channel Analog Fixed Input Memory Recorder provides a turnkey solution for both high-speed measurement at 1 MS/s and long-term measurement. Its ability to measure everything from high-to-low voltage signals allows it to play an important role in a variety of measurement scenarios.

 
Specifications
Analog Input Specifications
Measurement functionality 4-channel voltage measurement, switchable between instantaneous value (waveform) and RMS value
Input jacks Isolated BNC jacks (input resistance: 1 MΩ; input capacitance: 7 pF)
Max. rated input-to-ground voltage
  • 600 V AC/DC, measurement category III
  • 300 V AC/DC, measurement category IV (Inputs are isolated from other instrument circuitry. These figures represent the maximum voltage that can be applied between input channels and the instrument’s enclosure and between input channels themselves without damaging the instrument.)
Measurement ranges
  • 10 mV to 100 V/div, 13 ranges, full scale of 10 div
  • AC voltage that can be measured/displayed using high-speed function: 600 Vrms
  • Low-pass filter: 5/50/500/5k/50k Hz
Max. sampling speed 1 MS/s (4 channels sampled simultaneously)
Frequency characteristics DC to 100 kHz ±3 dB
Max. rated voltage between input terminals 600 V AC/DC (Representing the maximum voltage that can be applied between input jacks without damaging the instrument.)
Analog Input Specifications
Measurement functionality
  • High-speed function (high-speed recording)
  • Real-time function (real-time recording)
Max. sampling speed 1 MS/sec (1 μs period; all channels sampled simultaneously)
Internal memory capacity 14 bits x 1m word per channel (1 word = 2 bytes, not expandable)
External memory
  • CF card slot x 1 (up to 2 GB; supported formats: FAT/FAT32)
  • USB memory x 1 (USB 2.0 Standard-A receptacle)
Communications interfaces USB 2.0 Mini-B receptacle x 1
Functionality: Device configuration and measurement using communications commands; transfer of files from CF/USB memory to a computer (USB drive mode)
Operating environment (non-condensing)
  • Operating temperature range: -10°C to 50°C
  • Operating humidity range: 80% RH or less at -10°C to 40°C, 60% RH or less at 40°C to 45°C, 50% RH or less at 45°C to 50°C
  • When powering the instrument with the Z1000 battery: 0°C to 40°C, 80% RH or less
  • When charging the Z1000 battery: 10°C to 40°C, 80% RH or less
Storage environment
(non-condensing)
  • Storage temperature range: -20°C to 60°C
  • Storage humidity range: 80% RH or less at -20°C to 40°C, 60% RH or less at 40°C to 45°C, 50% RH or less at 45°C to 60°C
  • Z1000 battery: -20°C to 40°C, 80% RH or less
Standard compliance
  • Safety: EN61010
  • EMC: EN61326, EN61000-3-2, EN61000-3-3
  • Vibration resistance: JIS D 1601, Type 1: passenger vehicles; conditions: equivalent to Type A
Charging function (reference value at 23°C) Charge time: Approx. 3 hours (The charging function is activated by connecting the AC adapter while the BATTERY PACK Z1000 is attached to the instrument.)
 
Ordering Information
Model Description Buy Online Price
MR888020 Hioki MR8880-20 Memory HiCorder 4 Analog/Fixed Input Channels + 8 Logic Channels Memory Recorder Buy  Now $3,695.00
Included Accessories
  • 1 - AC adapter (Z1002)
  • 1 - Alkaline battery box
  • 1 - Strap
  • 1 - USB Cable
  • 1 - Wave Viewer Software
Included
Optional Accessories
MR9000 Hioki MR9000 Attachable Printer Unit for the MR8808-20 Buy  Now $649.00
C1003 Hioki C1003 Hard Carrying Case for the MR8880-20 Buy  Now $234.00
Z1000 Hioki Z1000 Battery Pack for LR8400-20 Series. NiMH, Charges while installed Buy  Now $259.00
Removable Storage
(Use only PC Cards sold by HIOKI. Compatibility/performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.)
9727 Hioki 9727 PC Flash Card 256MB Buy  Now $99.00
9728 Hioki 9728 512M Compact Flash Card Buy  Now $125.00
9729 Hioki 9729 1G PC Flash Card Buy  Now $189.00
9830 Hioki 9830 2GB CFC PC Card Supplied with PC Card adapter Buy  Now $270.00
Input Cables
9197 Hioki 9197 Test Lead Buy  Now $115.00
9198 Hioki 9198 Connection Cord for low voltage up to 300V 1.7m Discontinued
9243 Hioki 9243 Grabber Clips 9243 Red and Black Buy  Now $69.00
9322 Hioki 9322 Differential Probe Buy  Now $899.00
941815 Hioki 9418-15 AC Adapter Buy  Now $175.00
979001 Hioki 9790-01 Alligator Clip Buy  Now $39.00
979002 Hioki 9790-02 Grabber Clip Buy  Now $50.00
979003 Hioki 9790-03 Contact Pin Buy  Now $44.95
L9790 Hioki L9790 Connection Cord for MR8880-20 and 8870-20 Buy  Now $105.00
Clamp-on Probes/Sensors
327350 Hioki 3273-50 50MHz 30A AC/DC Current Probe Buy  Now $2,900.00
3274 Hioki 3274 10MHz 150A AC/DC Current Probe Buy  Now $3,780.00
3275 Hioki 3275 2MHz 500A AC/DC Current Probe Buy  Now $4,395.00
3276HIOKI Hioki 3276 100MHz 30A AC/DC Current Probe Buy  Now $4,395.00
901050 Hioki 9010- 50 Clamp on Probe AC 10/20/50/100/200/500 A Buy  Now $240.00
901850 Hioki 9018-50 AC Clamp On Transducer Buy  Now $369.95
927210 Hioki 9272-10 AC Current Probe Buy  Now $595.00
9278 Hioki 9278 Universal Clamp On Probe (200A) Buy  Now $1,790.00
9279 Hioki 9279 Universal Clamp On Probe (500A) Buy  Now $1,890.00
9675 Hioki 9675 10 Amp Clamp-on Sensor for the 3196/3197 Buy  Now $315.00
965710 Hioki 9657-10 AC Leak Sensor 10Amp CT Buy  Now $395.00

Hioki Catalog   |   Hioki Price List

$40.00 Minimum on Total Order