| Specifications |
|
Specifications |
Description |
|
Measurement Functions |
Number of Channels |
2 |
|
Type of Measurement |
Voltage
Measurements |
|
Input Connectors |
Insolated BNC Connector
(Input isolated from output, inter-channel isolation) |
|
Max. rated voltage to earth: 370 V AC, DC
|
|
Measurement Range |
5 mV to 20 V/division, 12 ranges, the
measurement resolution is 1/80 of range |
AC voltage for possible
measurement/display using the memory function:280Vrms
(When attached to recorder where full-scale (f.s.) = 20
divisions) |
|
10 mV to 50 V/division, 12 ranges, the
measurement resolution is 1/160 of range |
AC
voltage for possible measurement/display using the
memory function:280Vrms
(When attached to recorder where full-scale (f.s.) = 10
divisions) |
|
Low-pass filter:5/500/5 k/100 kHz |
|
Maximum sampling rate |
1 MS/s (simultaneous sampling of two
channels) |
|
Zero-position |
-50 % to 150 %, 1 % step (With
zero-adjustment function) |
|
Accuracy |
DC amplitude |
±0.4% f.s. |
|
Zero Position |
±0.1% f.s. |
|
Frequency characteristics |
DC to 400 kHz ±3 dB |
|
with AC coupling: 7 Hz to 400 kHz ±3 dB |
|
Max. allowable input |
400 V DC (the Maximum voltage which when
applied to between input pins does not damage them) |
|
Max. rated voltage to earth |
370 V AC, DC (upper voltage which when
applied to input channel casing or between input
channels does not damage them) |
|
Dimensions and Weight |
approx. 170 (6.69in) W × 20 (0.79in) H ×
148.5 (5.85in) D mm
approx. 290 g (10.2 oz) |
|
Additional Notes |
When using Model 8936 with serial number
earlier than 041018234 on Models 8860 or 8861, residual
noise will be 850 μVp-p |