| Specifications |
| DC Voltage range |
3.2 V to 600 V, 5 ranges, Best accuracy: ±0.5 % rdg. ±4 dgt. |
| AC Voltage range |
3.2 V to 600 V, 5 ranges, Best accuracy: ±2.0 % rdg. ±8 dgt. ,
Average rectifier effective value |
Frequency characteristics
at AC Voltage |
50 to 500 Hz |
| Resistance range |
320 ohm to 32 M-ohm, 6 ranges, Best accuracy: ±1.5 % rdg. ±4 dgt. |
| Continuity |
Possible (250 ohm or less) |
| Diode check |
Possible (1.7 V open terminal voltage) |
| Other functions |
320 mV DC special range: ±0.5 % rdg. ±4 dgt.
320 mV AC special range: ±2.0 % rdg. ±8 dgt. |
| Auto power save |
Possible (Cancel possible) |
| Range switching |
Auto or Manual |
| Display |
LCD, maximum 4199 dgt. |
| Sampling rate |
2.5 times/sec |
| Safety considerations |
Safety: EN61010-1 :1993, EN61010-2-031 :1994, Pollution Degree
2, overvoltage category III
EMC: EN55011 : 1991, EN50082-1 : 1992 |
| Power supply |
R03(AAA) × 2 dry batteries (Continuous use 400 hours) |
| Dimensions, mass |
70 mm (2.76 in) W × 145 mm (5.71 in) H × 31 mm (1.22 in) D, 200 g (7.1
oz) |