- Provides ten electrically isolated analog input channels for measuring voltage and temperature, plus four pulse-counting input channels. The isolated inputs alleviate constraints when measuring temperatures in live electrical circuits while minimizing interchannel interference
- 10 ms scanning of all channels provides rapid sampling capabilities To meet the demand for measuring sudden changes in load, this model tracks waveforms that earlier 100 ms models could not
- CompactFlash card makes direct recording a snap. For long-term data recording, transfer data to a PC via USB connection
- Widescreen, bright LCD gives excellent viewability. The beautiful, wide QVGA-TFT display is ideal for waveform monitoring
|

Hioki 843020 Shown
|
| Specification Hioki 843020 |
| No. of channels |
Analog 10 channels isolated scanning method input. (M3 mm dia. screw terninal block) Pulse input 4 channels (All pulse inputs share common ground with the main unit) |
| Measurement Parameters |
Voltage : ±100 mV to ±60 V, 1-5V f.s. 6 ranges, Max. resolution 5μV
Temperature (thermocouples) : -200°C to 2000°C (depend on the sensor), 1 range (K, J, E, T, N, R, S, B), Max. resolution 0.1°C
Temperature (Pt 100 sensor) : not available
Humidity : not available
Totalized pulses : 0 to 1000M count, 1 range (No-voltage 'a' contact, open collector or voltage input), Max. resolution 1 count
Rotation count : 0 to 5000/n (r/s) f.s. 1 range (No-voltage 'a' contact, open collector or voltage input), Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000) |
| Max. allowable input |
DC 60V (Analog input), DC -5V to 10V (Pulse input) |
| Max. rated voltage to earth |
DC 60V, AC 30Vrms (Upper limit voltage that does not cause damage when applied between input channel and chassis, and between each input channels) |
| Recording intervals |
10ms to 1hour, 19selections (All input channels are scanned at high speed during every recording interval) |
| Selectable Filters |
50Hz, 60Hz, or OFF (digital filtering of high frequencies on analog channels) |
| Data Recording Capacity |
Internal storage: 3.5MWords (7MB of two-byte data points, or four-byte pulse measurements)
External storage: Up to 2GB (HIOKI CF cards only) |
| External Interface |
One USB 2.0 series mini B receptacle
Functions: Control from a PC(Ver 1.00 or later),Transfers internal data on the CF card to a PC(Ver 1.10 or later) |
| Display |
4.3 inch WQVGA-TFT color LCD (480 × 272 dots) |
| Function |
Save data to the CF Card in real time, Numerical Calculation, External trigger input, Trigger output, Alarm output, Scaling |
| Power Sources |
(1) 100 to 240V AC, 50/60Hz using AC Adapter Model 9786
(2) Battery Pack Model 9780, Continuous operating time: Approx. 2.5 hours
(3) 12V battery (10 to 16V DC ±10%, please contact HIOKI for connection cord) |
|