Version 2.0, Model 9936A

LogWare's data logging features include
  • Data from many DewKs can be logged in real time via Ethernet, RS-232, or wireless connections
  • Supports "hot-swapping," which allows you to remove and replace sensors without shutting down the log session
  • Integrating with Fluke MET/CAL calibration and management software; imports readings into calibration records
  • Quick and easy configuration
  • Ability to save and open configuration files
  • Selectable sample interval from 1 second to 24 hours
  • Selectable delayed start date/time for off-hours real-time logging
  • Selectable end log options (to stop session after specified time or number of readings)
  • Logs all readings to a central data repository
  • Selectable high and low alarm settings with user defined events (can be configured to play .WAV file or launch an application, such as pager software, when an alarm trips)
    


Hart Scientific LogWare III Software Version 2.0, Model 9936AClick for larger image
9936A Shown      
 
Product Information
Datasheet 583 KB
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information
PDF Help
LogWare III is a Windows® application that retrieves, stores, and analyzes data from the Hart Model 1620A "DewK" Thermo-Hygrometer.

Major new features added to version 2.0

  • E-mail1 capabilities for status updates and out-of-tolerance notifications
  • Communicate with loggers using Ethernet or wireless2 communications
  • Remotely monitor any real-time log session from any client computer
  • Multi-user support - Install LogWare III on as many computers as you need3
  • Client/Server architecture - Central repository for all logged data
  • Run multiple concurrent real-time log sessions on each client
  • Improved security features including customizable user permissions
  • Support for new 1620A "DewK" Thermo-Hygrometer (logger)
  • And many more
  1. Requires access to SMTP mail server
  2. Requires optional RF modem
  3. License required for each concurrent user

LogWare's data graphing features include

  • Graphs readings and calculates statistics as they are being logged
  • Customize your graph trace color, alarms, and statistics
  • Graph temperature and humidity on same graph or on separate graphs
  • Graph zooming capability

LogWare's data analysis features include

  • Select data to display based on location or sensor and date/time range
  • Spreadsheet-style grid to view all logged readings
  • Statistical calculations
  • Export logged data to various file types
  • Highlighting and annotations can be appended to any reading
  • Can have multiple windows open simultaneously

LogWare's security features include

  • Built-in administrator account for performing administrative functions
  • User accounts for individual users or teams
  • Customizable permissions for each user account to restrict access to software features
  • User name and password required for login
  • Activate/deactivate individual user accounts to allow/prevent login
  • Activate/deactivate individual loggers, sensors, and locations to allow/prevent use

LogWare also provides these additional features

  • Customizable e-mail settings allow you to send e-mails to designated recipients, including cell phones and PDA's, when a log session begins, ends, or is aborted; when the DewK's battery is low; when a sensor calibration is due; or when a temperature/humidity alarm is exceeded; and more...
  • Viewing data stored in the central data repository from any LogWare III client computer on the network
  • Exporting data to multiple file types: HTML, RTF or ASCII text
  • Printing reports and graphs
  • Appending annotations to data points
Click for larger image      LogWare III remotely monitors and logs a virtually unlimited number of concurrent log sessions into a central data repository. That means data from many DewKs can be managed in real time via Ethernet, RS-232, or wireless connections.

Data may be logged from one or both of a DewK's sensors, providing up to two temperature and two humidity inputs for each DewK.

        
Click for larger image      LogWare III allows you to customize your graph trace color, alarms, and statistics as you go. You can start/stop log sessions from your computer. LogWare III supports "hot-swapping," which allows you to remove and replace sensors without shutting down the log session. LogWare III also supports security features such as passwords for individual users or groups/teams, a built-in administrator account, pre-defined user groups, and customizable permissions to ensure the integrity of all stored data.
     
Click for larger image      Never again be the last to know about a problem. Customizable e-mail settings allow you to send e-mails to designated recipients, including cell phones and PDA's, when a log session begins, ends, or is aborted; when the DewK's battery is low; when a sensor calibration is due; or when a temperature/humidity alarm is exceeded.
     
Click for larger image      If you cannot be reached via email, you can always arrange to be paged instead. Data stored on the DewK can be imported into the software, which is a handy feature when power outages disable the network.

Are you ready for a deep dive into your data? Historical data can be viewed by sensor (model/serial number) location or log session and displayed in a spreadsheet-style grid. Logged data can also be exported to HTML, RTF or ASCII text for use in your analytical software, or simply print historical data and graphs.

     
Click for larger image      Customizable graphs in LogWare III with zooming capability are an easy way to analyze your data history, and data points that need to be explained can be highlighted, annotated, and referred to later. LogWare III statistics include min, max, spread, average, and standard deviation functions, and printed reports keep track of the percentage of temperature and humidity measurements that were found to be out of tolerance.
 
Ordering Information
Model Description Buy Online Price
9936A Fluke Hart 9936A LogWare III Software, Single-PC License Buy Now $889.00

Hart Scientific Catalog   |  Hart Scientific Price List

$20.00 Minimum on Total Order

Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________

99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:

Copyright © Fotronic Corporation All Rights Reserved