General Tools CA10
AC Circuit Analyzer

  • Measures a branch circuit’s line voltage, peak voltage and neutral-to-ground voltage
  • Calculates a circuit’s voltage drop in response to 12A,15A and 20A loads
  • Measures the impedance of hot, neutral and ground conductors as well as available short-circuit current(ASCC)
  • Identifies wiring configurations and detects wiring faults and missing ground wires
  • Tests the reliability and response time of GFCIs(ground fault circuit interrupters) and RCDs (residual current devices)
  • Displays True RMS readings of all voltages except peak voltages
  • Works with 2- and 3-phase circuits
  • Jumbo LCD with 30-second backlight
  • Familiar menu/sub-menu operation
  • Data HOLD button and 30-minute auto power off
  • Powered by six “AAA” batteries (not included)
Click here for a larger image - General CA-10Click here for larger image - General CA 10
General CA10 Shown
Product Information
Manual 1.74 MB PDF
PDFPDF Help
General Tools CA10 AC Circuit Analyzer is ideal for identifying 110/220VAC power circuit and wiring problems that can cause shocks, sparks, fires, equipment failures and poor equipment performance.
Specifications
Line Voltage Measurement Range 85 to 265VAC 
Measurement Accuracy ± 1.0% ± 0.2V
Resolution 0.1V
Peak Voltage Measurement Range 121 to 374VAC
Measurement Accuracy ± 1.0% ± 0.2V
Resolution 0.1V
Line Frequency Measurement Range 45 to 65 Hz
Measurement Accuracy ±1.0%   ± 0.2Hz
Resolution 0.1Hz
Voltage Drop Measurement Range 0.1 to 99.9%
Measurement Accuracy ± 2.5%   ± 0.2%
Resolution 0.1%
Load Voltage Measurement Range 10 to 265V
Measurement Accuracy ± 2.5%   ± 0.2V
Resolution 0.1V
Neutral-to-Earth
Voltage
Measurement Range 0 to 10VAC
Measurement Accuracy ± 2.5%    ± 0.2V
Resolution 0.1V
Hot, Neutral and
Ground Line Impedance
Measurement Range 0 to 3Ω
Measurement Accuracy ± 2.5%± 0.02Ω
Resolution 0.01Ω
GFCI Triggering Time Measurement Range 1ms to 6.5 sec
Measurement Accuracy ± 1.0% ± 2ms
Resolution 1ms
RCD Triggering Time Measurement Range 1ms to 6.5 sec
Measurement Accuracy ± 1.0% ± 2ms
Resolution 1ms
RCD Triggering Current Measurement Range 30 to 37mA
Measurement Accuracy ± 1.0% ± 0.2mA
Resolution 0.1mA
Operating/Storage Temperature 32° to 122°F (0° to 50°C) @ <80% RH
Dimensions 7.6 x 3.1 x 1.5 in
Weight (without Batteries) 10.4 oz