| << Fluke
Networks Network Tester Selection Guide |
Fluke Networks LinkRunner Duo
Network Multimeter for Fiber and Copper Cables
|
| |
- Link at 10/100/Gig – identify device capabilities and
confirm actual connected speed/duplex status
- Ping key devices – measure response statistics of
DHCP, default router, DNS server, and other key devices or URLs
- Verify 802.1X settings – authenticate on 802.1X
secured networks; enter EAP type, user name, certificates, and
password
- Detect PoE service – verify availability, voltage
level, and pairs of Power over Ethernet per IEEE 802.3af
specifications
- Identify port (C/E/LLDP) – identify nearest switch
address, slot, and port with Cisco, Extreme, and IEEE Link Layer
Discovery Protocols
- Test cable wiremap – test wiremap and length; detect
miswires, shorts, split pairs or opens; measure distance to
faults with TDR
- Locate and ID cable – use IntelliTone digital toning,
hub blink feature, or optional cable IDs to locate cables at
patch panels or wall jacks
- Document test results – save link, ping, PoE,
security, and cable test results in unit and upload to PC with
USB cable
- See Also: Fluke Networks
LinkRunner Network Multimeter
|
 
Fluke Networks LinkRunner Duo Shown
|
|
|
| |
The Fluke Networks LinkRunner Duo is a the first speeds. That means
frontline technicians now frontline tools to establish links at
Gigabit speeds. That means frontline technicians now have the power
to troubleshoot Gigabit link problems before they’re escalated to
higher levels, giving network engineers more time to focus on
optimization, planning, and expansion.
The Fluke Networks LRDUO LinkRunnerDuo not only will discover the
presence of 802.1X, but can also gain authentication on 802.1X
networks. The included LinkRunner Connect Software can be used to
select EAP type, provide certificates, and enter passwords.
Technicians can now solve 802.1X conflicts and get users back up
and running fast.
The Fluke Networks LinkRunner-Duo are the first connectivity tools to
support the new IEEE Link Layer Discovery Protocol (LLDP) in
addition to the Cisco and Extreme Discovery Protocols (CDP and EDP).
That allows technicians to speed problem resolution by precisely
locating the nearest switch model, slot, and port.
When no test documentation is available, closing trouble tickets can
be a frustrating and time-consuming process. Finger pointing and
redundant testing are just a couple of the wastes that occur. The
Fluke Networks LinkRunner Duo eliminate these wastes by generating
objective, professional test reports that can be printed or routed
electronically. |
| |
| Specification Guide |
| Features |
Description |
| Media Access |
10BASE-T, 100BASE-TX,
1000BASE-T (IEEE 802.3), and PoE (IEEE 802.3af) |
| Cable Tests |
Pair lengths, opens, shorts, splits, crossed,
straight through, and cable ID |
| Tone Generator |
IntelliTone digital tone: [500 KHz]; analog
tones: [400Hz, 1KHz] |
| Ports |
Test ports: RJ45 ports; Application port:
mini-USB |
| Power Source |
4 AA batteries |
| Weight |
10 oz (311 grams) with batteries installed |
| Dimensions |
5.3" h x 3.1" w x 1.3" d
(13.46cm x 7.87cm x 3.30cm) |
| LinkRunner Connect Software |
Operates on Windows XP and 2000; supports
English, Spanish, French, German, Simplified Chinese, and
Japanese |
| Warranty |
One year |
| M12/ RJ45 Cable Specifications: |
| Cable type |
Ethernet cable, Cat5e, shielded, 2 pair AWG
26 stranded (7 wire), RAL 5021 (water blue), M12 4 pos. D- coded
on RJ45 connector |
| Number of positions |
4 |
| Fixed cable length |
2 m |
| Volume resistance |
≤ 5 mΩ |
| Insulation resistance |
≥ 100 MΩ |
| Ambient temperature |
-20°C to 50°C |
| Inflammability class acc to UL 94 |
V0 |
| Surge voltage category |
II |
| Pollution degree |
3 |
| Degree of protection |
IP20/IP67 |
| External cable diameter |
6.7 mm |
| Transmission characteristics |
Cat 5 (IEC 11801:2002), Cat 5e (TIA
568B:2001) |
|
| |
|
Ordering Information |
| Model | Description |
Buy Online |
Price |
| LRDUO |
Fluke Networks LRDUO LinkRunner Duo Network Multimeter for Fiber and Copper Cables |
 |
$1,495.00 |
| LRDUOCE |
Fluke Networks LRDUO LinkRunner Duo Network Multimeter/Ethernet Tester for Fiber and Copper Cables with Reflector and Li-Ion |
 |
$1,999.00 |
| LRDUOFTK |
Fluke Networks LRDUO-FTK Copper/Fiber Network Troubleshooting Kit (LRDUO + FTK1300) |
 |
$4,295.00 |
| Included Accessories |
|
Base Unit Includes:
- 1 - WireView Cable ID #1
- 4 - "AA" Batteries
- 1 - Connect Software CD
- 1 - USB Cable
- 1 - RJ45 coupler
- 1 - Getting Started Guide
- 1 - Resource CD with Users Guide and Software
|
Included |
| Optional Accessories |
| WIREVIEW26 |
Fluke Networks WIREVIEW 2-6, WIREVIEW CABLE ID SET 2 THRU 6 |
Discontinued |
|
CIQRJA
|
Fluke Networks CIQ-RJA CABLEIQ RJ45/11 MODULAR ADAPTOR |
 |
$50.00 |
|
CLIPSET
|
Fluke Networks CLIPSET Clip Set |
 |
$49.00 |
|
MT820063A |
Fluke Networks MT-8200-63A Intellitone 200 Probe |
 |
$132.00 |
| Support Options |
|
GLDLR
|
Fluke Networks GL-DLR GOLD SUPPORT 1-YR LINKRUNNER |
 |
$156.00 |
|
| |
| top > |
|