Fiber QuickMap

  • One-button troubleshooting – no lengthy set-up necessary
  • Six-second test time – no more blind troubleshooting that can last up to hours
  • Locate high loss incidents or breaks – find the most common causes of fiber failure
  • Locate reflective incidents – discover causes of bit error rates, a primary source of network performance degradation
  • Locate multiple incidents – quickly see potentially problematic connections in the channel

Click here for larger image - Fluke Networks FQM-MAINClick here for larger image - Fluke Networks FQM-MAIN
Fluke Networks FQM-MAIN Shown

Product Information
Datasheet 853 KBpdf
pdfPDF Help
 
The Fluke Networks FQM-MAIN Fiber QuickMap is a new category of enterprise fiber troubleshooter that leapfrogs the limited capability troubleshooters currently on the market, the Fiber QuickMap quickly and efficiently locates connections and breaks in multimode fiber with the press of one-button. By instantly (six second typical test time) providing distances to failures such as high loss and high reflectance incidents, it is the must-have troubleshooter for any technician who works with fiber in datacenters.
 
Fluke Networks FQM-MAIN Specification
Operating temperature
(with the battery)
0ºC to 50ºC
Non-operating temperature -20ºC to 60ºC
Operating relative humidity (without condensation) 95% (10ºC to 35ºC)
75% (35ºC to 40ºC)
uncontrolled <10ºC
Vibration Random, 5 Hz to 500 Hz,
MIL-PRF-28800F CLASS 2
Shock 1 meter drop test
Altitude 9,842 feet/3,000 metres
EMC EN 61326-1:2004
Battery type 2 AA alkaline batteries (no battery charger)
Battery life 1,500 tests (typical)
Laser safety Class 1 CDRH
Complies to EN 60825-2
LCD type Backlit black and white (segments)
Index of refraction range 1.45 to 1.5 (factory default is 1.468)
Auto turn off Automatically turns off after 5 minutes if no keys are pressed.
Factory calibration interval None
Output wavelengths 850 nm ± 10 nm
Laser classification Class 1 CDRH Complies to EN 60825-2
Dynamic range >11 dB
Maximum distance 1500 meters or 4921 feet
Distance Accuracy ± (1 m + 0.1% x length) for reflective incidents 1
± (3 m + 0.1% x length) for non-reflective incidents2
Testing speed <  6 seconds typical
Connector Removable/cleanable SC adapter, UPC polish
Fiber types tested 50/125 μm or 62.5/125 μm multimode
Detection of reflective incidents 3 -35 dB default threshold (User selectable: -20 dB to 5 dB increments)
Reflectance accuracy 4 ± 4 dB
Maximum reflectance measurement -20 dB
Detection of loss incidents5 0.70 dB default threshold (user-configurable from 0.5 dB to 6.1 dB in 0.2 dB increments)
Bulkhead quality If no fiber is attached or if the connector is dirty, the troubleshooter displays 0 m or 0 ft.
Live fiber detection Detects optical signals from 600 nm to 1050 nm and shows ACTIVE LINE if a signal is there. Looks for a signal every 3 seconds after the first detection. +7 dB maximum input power.
Certifications and compliance Conforms to relevant European Union directives
Conforms to relevant Australian standards
Listed by the Canadian Standards Association CSA C22.2 No. 61010.1.04
Conforms to FCC Rules, Part A
1. ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for reflective incidents: ±1 m from 1 m to 1.5 km.
2. ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for non-reflective incidents: ±2 m for lengths ≤15 m, otherwise ±1 m.
3. Finds and gives the location of an incident that has a reflectance larger than -55 dB. Detects incidents >1m after the bulkhead connector when the bulkhead reflectance is <35 dB. Detects incidents >3 m after an incident when the incident reflectance is <35 dB.
4. With a backscatter coefficient of -63 dB at 850 nm using a calibrated -14 dB reference
5. Detects incidents >10 m after the bulkhead connector or any prior incident when the bulkhead reflectance is <-35 dB and the reflectance of any prior incident is <-35 dB. The maximum link loss prior to the incident is <7 dB.
 
Ordering Information
Model Description Buy Online Price
FQMMAIN  Fluke Networks FQM-MAIN Fiber QuickMap mainframe Buy Now $1,999.00
Included Accessories
 
  • 1 -Carrying Pouch
  • 1 -User manual

Included

Kits
FQMKIT Fluke Networks FQM-KIT Fiber QuickMap Kit with 50um SC/LC Launch fiber and LC Adapter Buy Now $2,399.00
FTS900 Fluke Networks FTS900 Fiber QuickMap Kit with Test Reference Cords (50 and 62.5 um for both SC/SC and SC/LC), VisiFault Visual Fault Locator Buy Now $2,649.00
FTS1000 Fluke Networks FTS1000 Fiber QuickMap Kit. Troubleshooter Kit with Test Reference Cords (50 and 62.5 µm for both SC/SC and SC/LC), VisiFault Visual Fault Locator, and SimpliFiber Pro power meter and multimode source, and carrying case Buy Now $4,249.00
Optional Accessories
NFK11SMPLXSC Fluke Networks NFK1-1SMPLX-SC Simplex Reference test cord 62.5/125 ?m, SC/SC, 1 m Buy Now $52.00
NFK11SMPLXST Fluke Networks NFK1-1SMPLX-ST Simplex Reference test cord 62.5/125 ?m, SC/ST, 1 m Buy Now $52.00
NFK21SMPLXLC Fluke Networks NFK2-1SMPLX-LC Simplex Reference test cord 50/125 ?m, SC/LC, 1 m Buy Now $52.00
NFK21SMPLXSC Fluke Networks NFK2-1SMPLX-SC Simplex Reference test cord 50/125 ?m, SC/SC, 1 m Buy Now $52.00
NFK21SMPLXST Fluke Networks NFK2-1SMPLX-ST Simplex Reference test cord 50/125 ?m, SC/ST, 1 m Buy Now $52.00
GLDFQM Fluke Networks GLD-FQM 1 yr Gold Support for FQM-MAIN, FQM-KIT or FTS900 Buy Now $264.00
GLDFQMFTK Fluke Networks GLD-FQM-FTK 1 yr Gold Support for FTS1000, FTS1100 or FTS1100/E Buy Now $488.00