Phone 800-517-8431
HOME > FLUKENETWORKS > CERTIFICATION > CABLE-ANALYZER-QUAD-OLTS-INSP-DSX-5000QI120-GLD3

Fluke Networks DSX-5000QI120/GLD3

Versiv DSX-5000 CableAnalyzer w/Quad OLTS/INSP, 3 Year Gold Support


Status: Discontinued
Replaced By: DSX5000QIWGLD
Brand: Fluke Networks
Model No: DSX-5000QI120/GLD3
MPN: 4700006
Our Model No: DSX5000QI120GLD3
Condition: NEW
PDF Document Icon Data Sheet (2.14 MB)
DSX-5000QI120/GLD3

Replaced By:
DSX5000QIWGLD

Product Features:

  • Kit includes the DSC-5000 cable analyzer, the CertiFiber Pro Quad OLTS model, and the USB video Inspection camera
  • Includes a 3-year Gold support warranty
  • The DSX-5000 CableAnalyzer is ideal for every step of the copper certification process
  • Versiv enables users to accomplish more than ever with a cable tester, by accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of of technicians of all skill levels
  • Included WiFi adapter makes it easy to connect the Versiv Mainframe to Linkware Live
  • LinkWare management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple test that locates the problem
  • Built in Alien Crosstalk testing capability

Performance:

  • Ten second Cat 6A test time contributes to the fastest way to gain certification
  • Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  • Manage up to 12,000 test results with full graphics
  • Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  • 1 billion links reported on LinkWare management software

Standards:

  • Compliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) – IEC61935-1 & 11801-1-4, IEEE 802.3af, IEEE 802.3at, ANSI/TIA/EIA-568-C.2
  • Next generation balance drafts – IEEE 802.3, TIA TR42.7

The DSX-5000QiGLD3 CableAnalyzer Copper Certifier with the CertiFiber Pro Quad OLTS module enables testing and certification of twisted pair cabling for up to 10 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A or Class FA. The addition of the CertiFiber Pro Quad module and the fiber inspection camera is ideal for ground up for enterprise fiber optic cabling testing and tests for db-loss and fiber length. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down - setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers can not understand.

As part of the Versiv cabling certification product family, the DSX CableAnalyzer provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between profitability is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level V accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects. This product also includes 3 years of Fluke Networks Gold Support warranty.

Versiv Cabling Certification Product Family

The Versiv Cabling Certification Product Family has a modular design with swappable testing modules that provide four types of testing (copper and fiber optic cabling, and Ethernet and Wi-Fi network cabling) plus report generation software and a cloud service for managing jobs. Its ProjX System manages job requirements and progress from setup to systems acceptance, making sure all tests are completed correctly. The Taptive User Interface simplifies set up, eliminates errors and speeds up troubleshooting. The LinkWare Live cloud service gives you visibility and control of the whole process: you can set up and track your testers and inspect results from any mobile device while the job is in process. It even lets you upload and integrate results from multiple testers at multiple jobsites so you can quickly generate reports with the de-facto industry standard LinkWare PC.

Versiv Platform is Ready for Today's and Tomorrow's Jobs

Electrically centered plug design is compliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz with a future-ready design to support all hardware upgrades

The DSX5000QiGLD3 CableAnalyzer enables cable testing and certification for 10 Gigabit Ethernet deployments - whether it is an existing Cat 5e, Cat 6, Cat 6A or Class FA cabling system, the DSX tests to all industry standards. The electrically centered test plug results in the Level V accuracy designation introduced with IEC to support field testing to Class FA, 1000 MHz. The DSX exceeds the IEC Level V specification with less than half the allowable crosstalk margin, assuring you of higher confidence in results over the full frequency range. Higher performance cabling systems like Cat 6A have less tolerance to interference and less noise margin in general. Additionally complex Alien Crosstalk link-to-link certification is simplified by integrating the measurement capability into each copper module for 10GBASE-T testing.

The DSX is the first field tester to support balance measurements including Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL). TCL and ELTCTL are important measurements found in the cabling standards. They define a minimum performance for balance, the key parameter to help determine noise immunity. Industrial network owners/operators are especially interested in this property as it is a key parameter to help determine electromagnetic interference (EMI).

Fluke Networks' DSX-5000QiGLD3 CableAnalyzer meets the Intertek (ETL) Certification in accordance with the IEC-61935-1 specifications for accuracy Level IV, the draft accuracy Level V and in accordance with the ANSI/TIA-1152 specifications for Level IIIe.

TLC Graph View Click for larger image

TLC Graph View

ELTCTL Graph View Click for larger image

ELTCTL Graph View

ProjX Management System Manages Complex Jobs with Ease

Manage up to 12,000 test results with full graphics

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and can be hard to manage. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX5000QiGLD3 provides individual project files for all job specific details to be saved under a simple name. Eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and always defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The "Fix Later" selection creates a punch list or automatic to do list for correcting any workmanship. ProjX enables project managers and crew leaders to be truly efficient.

Project Menu screen shows percent complete per job Click for larger image

Project Menu screen shows percent complete per job

Project specific screen shows up to the minute project details Click for larger image

Project specific screen shows up to the minute project details

Taptive User Interface Simplifies Set Up, Eliminates Errors and Speeds Troubleshooting

Capacitive touchscreen allows quick tester setup and supports all standards

Taptive user interface is easy enough for even the newest technician to perform tests across multiple media types and testing requirements. The capacitive Taptive user interface makes all jobs easily accessible from the menu screen. Touch the job you’re working on and the large display confirms the test that needs to be performed, animated instructions simplify setting the tester configuration making correct testing assured.

Simple Set up

Simple Set up

Performs with Unsurpassed Speed

Ten second Cat 6A test time and the fastest way to submit your certification results

No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 10 seconds or certify two fibers at two wavelengths in both directions in just 3 seconds. Endorsed by cabling vendors worldwide assures that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.

Passing test result Click for larger image

Passing test result

Return loss graph Click for larger image

Return loss graph

Pinch and zoom for more detail Click for larger image

Pinch and zoom for more detail

Troubleshoot Like an Expert

Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting

The DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple 1 button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are happening on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the DSX CableAnalyzer has no limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.

High Definition Time Domain Cross talk (HTDTX) shows the far end connection is clearly the issue

High Definition Time Domain Cross talk (HTDTX) shows the far end connection is clearly the issue

Shield continuity historically is a direct current- DC measurement -with no distance to fault available. The DSX CableAnalyzer is the first field tester to report distance to shield integrity issues using a patented A.C. measurement technique. This is especially important in datacenters. Other testers will show the shield connected even when it isn’t, because the racks in a datacenter are common grounded. Other testers may tell you there is a break in a shield, but not pinpoint the exact location giving no indication of where to start rework.

Wiremap – shows distance to fault, break and short

Wiremap – shows distance to fault, break and short

LinkWare Live

LinkWare Live is a Software as a Service from Fluke Networks for cabling professionals managing multiple projects that quickly, easily and affordably provides unmatched job visibility and superior project control from anywhere at anytime.

LinkWare Live provides an easy to read dashboard that shows an overview of the project status and a project activity to ensure projects are completed on time. It removes the hurdles in data management by giving the ability to directly upload and consolidate test results from multiple testers. You can quickly validate projects and test results in real-time with browser based ease to avoid any future rework due to incorrect testing or missing test results. Use any smart device with a browser to validate and check projects or test results. LinkWare™ Cable Test Management Software also connects to the LinkWare Live service enabling you to download test results into the LinkWare Cable Test Management Software to generate professional reports in a common format.

DSX-5000QiGLD3 cable analyzer connects to the LinkWare Live Service to directly upload results from the tester which provide access to test-results in real-time from anywhere.

LinkWare Management Software

Leveraging the popular and multi-featured LinkWare management software application, DSX-5000QiGLD3 CableAnalyzer users can easily access the ProjX management system data, generate reports, and upgrade the software in their testers. Project Managers have full capabilities to manage workflow and consolidate test results. Users can provide the finishing touch by adding their company logo to the report and offer it unaltered to their customers for system acceptance purposes. Keep your business tools simple, no matter which Fluke Networks copper or fiber tester you are using, LinkWare is the software package that reports it all

Now with LinkWare stats, the new automated statistical report option, you can move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.

Cable Types
Shielded and unshielded pair LAN cabling: TIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω
ISO/IEC Class C, D, E, EA, F, and FA: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent link adapters: Plug type: shielded RJ45
Optional Plug type: Tera
Channel Adapters: Jack type: shielded RJ45
Optional Jack type: Tera
Test Standards
TIA: Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2
ISO/IEC: Class C and D, E, EA, F, FA certification per ISO/IEC 11801:2002 and amendments
Maximum frequency: 1000 MHz
General Specifications
Speed of Autotest: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Support test parameters (The selected test standard determines the test parameters and the frequency range of the tests): Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input protection: Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display: 5.7 in LCD display with a projected capacitance touchscreen
Case: High impact plastic with shock absorbing overmold
Dimensions: Main Versiv unit with DSX-5000 module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight: Main Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote: Lithium ion battery pack, 7.2 V
Typical battery life: 8 hours
Charge time: Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported: English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese
Calibration: Service center calibration period is 1 year
Environment Specifications
Operating Temperature: 32° F to 113° F (0° C to 45° C)
Storage Temperature: -4° F to +122° F (-20° C to +50° C)
Operating relative humidity: 0 % to 90 %, 32° F to 95° F (0° C to 35° C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)
Vibration: Random, 2 g, 5 Hz-500 Hz
Shock: 1 m drop test with and without module and adapter
Safety: CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2
Operating altitude: 13,123 ft (4,000 m)
EMC: EN 61326-1
Performance Specifications
Category 6A/Class EA test modes (or lower link categories): DSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes: DSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling
Without Remote With Remote
Range: 800 m (2600 ft) 150 m (490 ft)
Resolution: 0.1 m or 1 ft 0.1 m or 1 ft
Accuracy: ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
± (0.3 m + 2 %)
Propagation Delay
Without Remote With Remote
Range: 4000 ns 750 ns
Resolution: 1 ns 1 ns
Accuracy: ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
± (2 ns + 2 %)
Delay Skew
Range: 0 ns to 100 ns
Resolution: 1 ns
Accuracy: ± 10 ns
DC Loop Resistance Test
Range: 0 Ω to 540 Ω
Resolution: 0.1 Ω
Accuracy: ± (1 Ω + 1 %)
Overload recovery time: Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
  • 1 - Versiv Mainframe & Remote
  • 2 - DSX-5000 CableAnalyzer Modules
  • 1 - WiFi Adapter for Versiv Mainframe
  • 2 - CertiFiber Quad OLTS Modules
  • 1 - Set of CAT 6A/Class EA Permanent Link Adaptors
  • 1 - Set of CAT 6A/Class EA Channel Adaptors
  • 2 - Headsets
  • 2 - Handstraps
  • 2 - Shoulder Straps
  • 1 - Large Carry Case
  • 1 - USB Interface Cable
  • 2 - Software CD's
  • 2 - AC Chargers
  • 2 - Universal Couplers
  • 2 - AxTalk Terminators
  • 1 - USB Video Inspection Probe w/ 4 Tips
  • 2 - OneClick Cleaner (1.25/2.50 mm)
  • 2 - LC/LC Simplex Adaptors
  • 1 - SC/LC EF-Compliant MM TRC Kit 50 µm
  • 1 - SC/LC SM TRC Kit
  • 1 - TRC Carry Case
  • 1 - Statement of Calibration
  • 1 - Getting Started Guides
  • 1 - 3 year of Gold Support coverage
Model Description Buy Now Price
DSX-PLA001 Fluke Networks DSX-PLA001 DSX Universal Permanent Link Adapter - Accepts Personality Modules Add to Cart
($849.00)
Sale $725.60
DSX-PLA004S Fluke Networks DSX-PLA004S DSX CAT 6A/CLASS EA Permanent Link Adapter Set Add to Cart
($1,095.00)
Sale $935.84
DSX-PLA011S Fluke Networks DSX-PLA011S DSX TERA CAT 7A/CLASS FA Permanent Link Adapter Set Add to Cart
($1,350.00)
Sale $1,153.78
DSX-CHA003 Fluke Networks DSX-CHA003 Single DSX Series Coaxial Adapter Add to Cart
($495.00)
Sale $423.06
DSX-COAX Fluke Networks DSX-COAX DSX Series Coaxial Adapter Set Add to Cart
($795.00)
Sale $679.44
DSX-CHA004S Fluke Networks DSX-CHA004S Cat 6A/Class EA Channel Adapter Set Add to Cart
($525.00)
Sale $448.69
DSX-CHA011S Fluke Networks DSX-CHA011S TERA Cat 7A/CLASS FA Channel Adapter Set Add to Cart
($545.00)
Sale $465.78
DSX-TERA-KIT Fluke Networks DSX-TERA-KIT TERA Cat 7A/CLASS FA Adapter and Charger Kit Add to Cart
($1,445.00)
Sale $1,234.97
DSX-CHA012S Fluke Networks DSX-CHA012S DSX GG45 CAT 7A/Class FA Channel Adapter Set Add to Cart
($545.00)
Sale $465.78
DSX-CHA021S Fluke Networks DSX-CHA021S DSX M12 4-Position Channel Adapter Set Add to Cart
($730.00)
Sale $623.90
DSX-PC5ES Fluke Networks DSX-PC5ES Set Of DSX Cat 5E Adapters with Cat 5E Patch Cord Jacks Add to Cart
($1,415.00)
Sale $1,209.33
DSX-PC6S Fluke Networks DSX-PC6S Set Of DSX Cat 6 Adapters with Cat 6 Patch Cord Jacks Add to Cart
($1,415.00)
Sale $1,209.33
DSX-PC6AS Fluke Networks DSX-PC6AS Set Of DSX Cat 6A Adapters with Cat 6A Patch Cord Jacks Add to Cart
($1,415.00)
Sale $1,209.33
DSX-5000 MOD Fluke Networks DSX5000MOD Versiv DSX Module Replacement Add to Cart
($4,200.00)
Sale $3,589.53
VERSIV-M 120 Fluke Networks VERSIV-M 120 VERSIV Main Replacement Add to Cart
($2,550.00)
Sale $2,179.36
VERSIVRU Fluke Networks VERSIV-RU Remote Replacement Add to Cart
($2,050.00)
Sale $1,752.03
VERSIV-TSET Fluke Networks VERSIV-TSET VERSIV Headphones Add to Cart
($55.00)
Sale $47.90
VERSIV-ADP-WIFI Fluke VERSIV-ADP-WIFI WIFI ADAPTER FOR VERISV MAINFRAM Add to Cart

$39.00

VERSIV-CASE3 Fluke Networks VERSIV-CASE3 VERSIV Hardsided Case Add to Cart
($1,050.00)
Sale $897.39
VERSIV-LG-CASE Fluke Networks VERSIV-LG-CASE Large Carrying Case for Versiv Products Add to Cart
($200.00)
Sale $170.93
VERSIV-SM-CASE Fluke Networks VERSIV-SM-CASE VERSIV Small Carry Case Add to Cart
($105.00)
Sale $99.75
VERSIV-BACKPK-STRP Fluke Networks VERSIV-BACKPK-STRP Backpack Strap for Versiv Large Case Add to Cart
($65.00)
Sale $55.56
VERSIVBATTERY Fluke Networks VERSIV-BATTERY VERSIV Replacement Battery Add to Cart
($425.00)
Sale $363.23
VERSIV-ACUN Fluke Networks VERSIV-ACUN VERSIV Charger Add to Cart

Replaced By:
PWRSPLY30W

VERSIV-STRP Fluke Networks VERSIV-STRP Strap Kit Add to Cart
($65.00)
Sale $56.60
VERSIV-STND Fluke Networks VERSIV-STND VERSIV Demo Stand Add to Cart
($70.00)
Sale $61.00
DSX-REFMOD Fluke Networks DSX-REFMOD Module Set Add to Cart
($535.00)
Sale $457.24
DSX 5000 CableAnalyzer getting started part 1 Unboxing
DSX 5000 CableAnalyzer getting started part 1 Unboxing
DSX 5000 CableAnalyzer getting started part 2 Setting up
DSX 5000 CableAnalyzer getting started part 2 Setting up
DSX 5000 CableAnalyzer getting started part 3 Running a test
DSX 5000 CableAnalyzer getting started part 3 Running a test
DSX 5000 CableAnalyzer creating a report
DSX 5000 CableAnalyzer creating a report
DSX 5000 CableAnalyzer Setting up for a Cat 5e Permanent Link
DSX 5000 CableAnalyzer Setting up for a Cat 5e Permanent Link
DSX 5000 CableAnalyzer Shield Integrity
DSX 5000 CableAnalyzer Shield Integrity
DSX 5000 CableAnalyzer NEXT failed due to poor termination
DSX 5000 CableAnalyzer NEXT failed due to poor termination
DSX 5000 CableAnalyzer Return Loss failes due to cable example 1
DSX 5000 CableAnalyzer Return Loss fails due to cable example 1
DSX 5000 CableAnalyzer Return Loss fails due to cable example2
DSX 5000 CableAnalyzer Return Loss fails due to cable example2
DSX 5000 CableAnalyzer NEXT fails on a short link
DSX 5000 CableAnalyzer NEXT fails on a short link
DSX 5000 CableAnalyzer Return Loss fails due to water in the cable
DSX 5000 CableAnalyzer Return Loss fails due to water in the cable
DSX 5000 CableAnalyzer NEXT fails due to cable
DSX 5000 CableAnalyzer NEXT fails due to cable
DSX 5000 CableAnalyzer Lubricant causes Insertion Loss to fail
DSX 5000 CableAnalyzer Lubricant causes Insertion Loss to fail
DSX 5000 CableAnalyzer Poor balance resulted in a 1000BASE T switch operating at 100BASE TX
DSX 5000 CableAnalyzer Poor balance resulted in a 1000BASE T switch operating at 100BASE TX
DSX 5000 CableAnalyzer The 3 dB rule
DSX 5000 CableAnalyzer The 3 dB rule
DSX 5000 CableAnalyzer The 4 dB rule
DSX 5000 CableAnalyzer The 4 dB rule
DSX 5000 CableAnalyzer 10% length rule
DSX 5000 CableAnalyzer 10% length rule
DSX 5000 CableAnalyzer Setting a Reference
DSX 5000 CableAnalyzer Setting a Reference
DSX 5000 CableAnalyzer Setting up for a two pair Category 5e Permanent Link
DSX 5000 CableAnalyzer Setting up for a two pair Category 5e Permanent Link
Data Sheet: PDF Document Icon (2.14 MB)
Manual: PDF Document Icon (4.18 MB)
Quick Start Guide: PDF Document Icon (785 KB)
Brochure: PDF Document Icon (520 KB)
↑ Back to Top