Fluke 113
Specifications |
|
Function |
Range |
Resolution |
Accuracy |

Volts
|
Measurement |
6.000 V
60.00 V
600.0 V |
0.001 V
0.01 V
0.1 V |
DC, 45 to 500 Hz:
2.0% + 3
500 Hz to 1 kHz:
4.0% + 3 |
Input Impedance
(Nominal) |
~3kW<300 pF |
Common Mode Rejection Ratio
(1 kΩ Unbalanced) |
60 dB at DC,
50 or 60 Hz |

Diodes |
Measurement |
Range |
Resolution |
Accuracy |
|
2.000 V |
0.001 V |
2.0% + 3 |
Open Circuit
Test Voltage |
< 2.7 V DC |
|
Full Scale Voltage |
< 0.7 V DC |
|
Short Circuit Current |
< 350 µA |

Sound |
Measurement |
Range |
Resolution |
Accuracy |
|
- |
- |
Beeper on < 20 Ω, off > 250 Ω;
Detects open or shorts of 500
µs or longer |

OHMs |
Measurement |
Range |
Resolution |
Accuracy |
|
600.0 Ω
6.000 kΩ
60.00 kΩ |
0.1Ω
0.01 kΩ
0.001 kΩ |
0.9% + 2
0.9% + 1
0.9% + 1 |
Open Circuit
Test Voltage |
< 2.7 V DC |
|
Full Scale Voltage |
2.000 V DC |
|
Short Circuit Current |
< 1.0 mA |

Capacitors |
Measurement |
Range |
Resolution |
Accuracy |
|
1000 nF
10.00 µF
100.0 µF
9999 µF |
1 nF
0.01 µF
0.1 µF
1 µF |
1.9% + 2
1.9% + 2
1.9% + 2
100 µF - 1000 µF: 1.9% + 2; >1000 µF: 5% + 20 |
|
Additional note for all functions: |
- All VChek voltage ranges are specified from 60 counts
to 100% of range. Because inputs below 60 counts are not specified, it
is possible and normal for this and other true-rms meters to display
non-zero readings when the test leads are disconnected from a circuit or
are shorted together
- Crest factor of ≤3 at 4000 counts, decreasing
linearly to 1.5 at full scale
- After measuring voltage, a wait time of 1 minute is
required to maintain accuracy, ohms, capacitance, diode test, and
continuity
|
|
Specifications |
Details |
|
Accuracy |
0.5% |
|
Features |
True RMS |
Yes |
|
Capacitance |
Yes |
|
Display Backlight |
Yes |
|
MIN/MAX/AVG |
Yes |
|
Probe Holders |
Yes |
|
Maximum Voltage between any
terminal and earth ground |
600V |
|
Temperature coefficient |
0.1 x (specified accuracy)/°C
(< 18°C or > 28°C) |
|
Temperature |
Operating |
-10°C to 50°C (14°F to
122°F) |
|
Storage |
-40°C
to 60°C (-22°F to 140°F) |
|
Altitude |
Operating |
2,000 m |
|
Storage |
10,000 m |
|
Relative Humidity |
95% at 30°C |
|
75% at 40°C |
|
45% at 50°C |
|
Shock |
1 Meter drop per IEC 61010-1-2001 |
|
Vibration |
Per MIL-PRF-28800 for Class 2 instrument |
|
Safety |
Complies with ANSI/ISA 82.02.01 (61010-1), 2004,
CAN/CCSA-C22.2 No. 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd
edition for measurement Category III, 600 V, Pollution degree 2, EMC
EN61326-1 |
|
EMI Regulation |
Complies with FCC Part 15, class B |
|
Display |
3 3/4-digits, 6000 counts, updates 4/sec |
|
Battery |
Type |
9 Volt Alkaline, ANSU 1604A/IEC 6F22 |
|
Cover Type |
Battery Door (for quick battery
changes) |
|
Life |
300 hour typical, without Backlight |
|
Physical Dimensions |
Size |
6.58" x 3.35" x 1.81" inches (167.1mm x 85.1mm x 46mm) |
|
Weight |
404 grams (13.0 oz) |