HOME > FLUKE > ACCESSORIES > TEST-LEADS-PROBES-CLIPS > DP120 fluke logo

Fluke DP120 Differential Probe
Discontinued

  • Designed to make measurements on signals with floating reference
  • Has two probes with shrouded banana probe tips (one red, one black) and shielded cable for improved noise immunity.
  • Input impedance between each input to shielding BNC is 5 MΩ in parallel with 6 pF
  • Input impedance between the inputs is 10 MΩ with a capacitance of 5 pF.
Click here for a larger image of the Fluke DP120Click for larger image
Fluke DP120 Shown
 
Specification 
Input Probes with shrouded banana probe tip
Probe length 1.5 meter (60 inch)
Maximum Input Voltage to Ground 600V rms CAT III per IEC 1010-2-031 / 1000Vrms CAT II, per IEC 1010-2-031 
Maximum Differential Voltage 1000V DC or1000Vrms or 1200V (DC + ACpeak)
Output Cable Safety designed 0.5m (5ft) BNC Cable
Attenuation 200x and 20x
Bandwidth DC to 20 MHz (-3 dB)
Accuracy ±2.5%
CMRR 200x: @ 60 Hz = 80dB, @ 1 MHz = 50 dB 20x: @ 60 Hz = 70dB, @ 1 MHz = 40 dB
Power Adapter PM 8907/80n (optional)
 
Ordering Information
Model Description Buy Online Price
Fluke DP120
MFR ID: 651759
Fluke DP120 Differential Probe Discontinued
Included Accessories
 
  • 1 - AC85A Large Jaw Alligator Clips
  • 1 - AC83 Pin-Grabber Test Clips
Included