Fieldpiece SRH2
Diagnostic Sling Psychrometer
Discontinued
See: SRH3

Click here for a larger image of the Fieldpiece SRH2 Diagnostic Sling PsychrometerClick here for a larger image
Fieldpiece SRH2 Shown
Product Information
Datasheet 3.2 MB PDF Datasheet
Manual 3.1 MB PDF Datasheet
PDF HelpPDF Help
  • TSH and TEET built in
  • Choose the NTC or the included WB and DB T/Cs for testing
  • Faster testing and system diagnosis
  • Higher quality job
  • Test multiple parameters with one instrument
  • Quick, easy testing from two sensor sources
  • Clip thermocouples to keep them in place during tests
  • Auto power off (APO) after 15min of inactivity
  • MAX/MIN/Hold Functions
  • Easy to access thermocouple synchronization
  • Bright blue Backlight
  • Magnetic hanger and rugged rubber boot for functionality and durability
The Fieldpiece SRH2 Diagnostic Psychrometer is an easy to use hand-held diagnostic instrument that performs the normal functions of a digital psychrometer plus it calculates critical air conditioning system targets from psychometric measurements.
  • Measures temperature (DB) and %relative humidity (%RH)
  • Calculates wet bulb (WB) and dew point (DP)
  • Calculates Target Superheat (TSH)
  • Calculates Target Evaporator Exit Temp (TEET) (aka - delta T, temp split)
  • Only digital psychrometer that takes measurements using an electronic sensor (NTC) or k-type thermocouples (T/C)
 
Specifications
Temperature
(K-Type Thermocouple):
Range: -58°F to 1832°F (-50°C to 1000°C)
Accuracy: ±1°F 50°F to 113°F (±0.5°C 10°C to 45°C), when calibrated to NTC at room temperature
±(0.1% rdg+2°F) -58°F to 1832°F
±(0.1% rdg+1°C) -50°C to 1000°C
Temperature
(NTC):
Range: 32°F to 140°F (0°C to 60°C)
Accuracy: ±1°F 50°F to 113°F (±0.5°C 10°C to 45°C) ±4°F 32°F to 50°F and 113°F to 140°F ±2°C 0°C to 10°C and 45°C to 60°CC
Relative
Humidity
Range: 0% to 100%RH
Accuracy: ±2.5% at 77°F (25°C), 10% to 90%RH
±5% at 77°F (25°C) 0 to 10% RH & 90 to 100% RH
Operating temperature: 0°F - 122°F at <75%RH
Storage temperature: -4°F to 140°F (-20°C to 60°C) 0 to 80%RH with battery removed
Battery life: Approx. 150 hours (9V alkaline)
Low battery indication: The +- symbol is displayed when the battery voltage drops below the operating level
Auto Shut off: 15 minutes of inactivity
Dimensions: 7.9 in (H) x 2.6 in (W) x 1.4 in (D), [200mm (H) x 66mm (W) x 36mm (D)]
Weight: Approx. 11oz with battery installed
 
Ordering Information
Model Description Buy Online Price
SRH2 Fieldpiece SRH2 Diagnostic Sling Psychrometer Discontinued
See: SRH3
Included Accessories
  • 1 - K-type dry bulb thermocouple w/ clip (ATA1)
  • 1 - K-type wet bulb thermocouple w/ clip (ATWB1)
  • 1 - Battery
  • 1 - Operator’s Manual
Included